• 제목/요약/키워드: Control signal

검색결과 6,367건 처리시간 0.036초

Adaptive Beamformer Using Signal Location Information for Satellite

  • Kim, Se-Yen;Hwang, Suk-seung
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권4호
    • /
    • pp.379-385
    • /
    • 2020
  • The satellite employs an adaptive beamformer to efficiently detect various signals and to suppress multiple interference signals, simultaneously. Although the adaptive beamforming satellite system needs Angle-of-Arrival (AOA) information of the desired signal, it is difficult to estimate the signal AOAs on the satellite environment. However, the AOA estimation on the ground control tower is more efficient and accurate comparing to the satellite environment. In this paper, we propose an adaptive beamforming satellite system based on the signal location information on the ground, consisting on an angle estimator, an adaptive beamformer, and signal processing & D/B unit. The ground control tower estimates the accurate location of the signal source, and it sends the estimated coordinates of the desired signal to the satellite. The angle estimator mounted on the satellite calculates the desired signal AOA, based on the signal location information transmitted from the ground control center. The satellite beamformer detects the desired signal and suppresses unwanted signals based on the signal AOA calculated by the angle estimator. We provide computer simulation results to present the performance of the proposed satellite adaptive beamforming system based on the signal location information.

열차의 고밀도운전을 위한 신호보안 시스템에 관한 연구 (A study on the railway signal system for high density traffic)

  • 강규현;김희식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.163-166
    • /
    • 1997
  • In order to shorten head-way time on existing railway lines without any change of signal block length between stations, it is a realistic optional way to change the control method of train signal, i.e. to modernize the cab signal using transponder. A new signalling system of operation pattern control technique is suggested as new model to increase the railway traffic efficiency. Through the computer simulation of this model, the train head-way time by the fixed signalling system and the new pattern control system is analyzed.

  • PDF

Research on the Correlation of Control Malfunction with Induced Voltage of Control Signal Line According to Voltage Change of a Power Line

  • Kang, Dong-Woo;Kim, In-Gun;Ham, Sang-Hwan;Kim, Sung-Yul;Bae, Sungwoo;Kim, Dae-Nyeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.775-780
    • /
    • 2016
  • This induced voltage measurement test and electromagnetic field simulation are related to the possibility of control signal malfunction by power line. Through an experiment, this research analyzed whether the voltage causing control malfunction according to the on/off status of power permitted to power line was induced to control signal line. Also, the research calculated the voltage induced to control signal line and examined the phenomenon by conducting an electro-magnetic field-specific simulation through the finite element method for the cable model used in the experiment.

영상에서 객체 추출을 통한 적응형 통행 우선순위 교통신호 제어 시뮬레이션 (Simulation of Traffic Signal Control with Adaptive Priority Order through Object Extraction in Images)

  • 윤재홍;지유강
    • 한국멀티미디어학회논문지
    • /
    • 제11권8호
    • /
    • pp.1051-1058
    • /
    • 2008
  • 영상처리와 통신 기술의 진보는 통합된 시스템의 일부분으로써 긴급 차량 우선권과 통행 우선 방법 모두를 수용하기 위한 현행 교통 신호 제어기들과 차량 탐지 기술을 가능하게 만들고 있다. 횡단보도에서 현행 교통 신호제어는 고정된 신호 주기에 따라 변하도록 구성되어 있다. 고정된 신호 주기의 신호제어 체계는 통행량이 없는 상황에서도 일정한 신호주기가 주어지기 때문에 상대적으로 교통량이 많은 곳에서는 해당 진행 신호가 부여될 때까지 대기해야 한다. 이러한 대기 시간은 신호 위반에 따른 교통사고의 위험과 교통체증을 유발하게 된다. 본 논문에서는 교통사고의 위험과 교통 체증을 해소하기 위한 방안으로 객체 검출영상을 통하여 현장상황에 맞게 우선적으로 신호가 부여될 수 있도록 적응형 우선순위 교통신호 제어 시스템을 설계하고 시뮬레이션 하였다.

  • PDF

타워형 에어컨 송풍기 소음의 능동제어 (Active Control of Noise from Fan Blowers in Tower-type Air Conditioners)

  • 류경완;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.87-93
    • /
    • 2017
  • This paper investigates active noise control of tower-type air conditioners using the filtered-x least mean square (FXLMS) algorithm to reduce fan blower noise transmission. Firstly, the main components required for the active control system including the error sensor, the control speaker and the reference sensors are selected. Since the noise could significantly reduce if the reference signal includes every frequency response information, a various reference signals from accelerometers and a microphone are used. Secondly, the controller based on the FXLMS algorithm with a single-channel reference signal is implemented. Then, the control performance is examined experimentally for the different reference signals. It is found that the accelerometer signal well possesses the motor vibration related noise and a microphone signal could includes global noise. When using the reference signal with a microphone located near the motor and the fan blower, the active control system reduces the noise globally, except for several peaks.

EPD 신호궤적을 이용한 플라즈마 식각공정의 실시간 이상검출 (Real-time malfunction detection of plasma etching process using EPD signal traces)

  • 차상엽;이석주;고택범;우광방
    • 제어로봇시스템학회논문지
    • /
    • 제4권2호
    • /
    • pp.246-255
    • /
    • 1998
  • This paper presents a novel method for real-time malfunction detection of plasma etching process using EPD signal traces. First, many reference EPD signal traces are collected using monochromator and data acquisition system in normal etching processes. Critical points are defined by applying differentiation and zero-crossing method to the collected reference signal traces. Critical parameters such as intensity, slope, time, peak, overshoot, etc., determined by critical points, and frame attributes transformed signal-to symbol of reference signal traces are saved. Also, UCL(Upper Control Limit) and LCL(Lower Control Limit) are obtained by mean and standard deviation of critical parameters. Then, test EPD signal traces are collected in the actual processes, and frame attributes and critical parameters are obtained using the above mentioned method. Process malfunctions are detected in real-time by applying SPC(Statistical Process Control) method to critical parameters. the Real-time malfunction detection method presented in this paper was applied to actual processes and the results indicated that it was proved to be able to supplement disadvantages of existing quality control check inspecting or testing random-selected devices and detect process malfunctions correctly in real-time.

  • PDF

A Realization Method of Fault-tolerant Control of Flexible Arm under Sensor Fault by Using an Adaptive Sensor Signal Observer

  • Izumikawa Yu;Yubai Kazuhiro;Hirai Junji
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.8-17
    • /
    • 2006
  • In this paper, we propose a fault-tolerant control system for the position control and vibration suppression of a flexible arm robot. The proposed control system has a strain gauge sensor signal observer based on a reaction force observer and detects a fault by monitoring an estimated error. In order to improve the estimation accuracy, the plant parameters included in the sensor signal observer are updated by using the strain gauge sensor signal in normal time through the adaptive law. After fault detection, the proposed control system exchanges the faulty sensor signal for the estimated one and switches to a fault mode controller so as to maintain the stability and the control performance. We confirmed the effectiveness of the proposed control system through several experiments.

Dynamic Investigation of the Brushless DC Motor

  • Sirilappanich, Surachet;Somchaiwong, Nitipong;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1867-1870
    • /
    • 2003
  • The analysis and simulation are the method to study the behavior, response, and specification of the driver device. This paper proposes brushless DC drive which using the vector control technique. The encoder is used detect the rotor position and decode to Three-phase step signal. The step signal is modulated with triangle signal and change to the pulse width modulation (PWM) signal. The PWM signal is used for control the input power of the motor based on the vector control technique. The experimental results of the driver circuit and motor response performed under the following condition: as the motor was started, change the load torque, and vary the supply voltage. The experimental performs with a dynamometer and the test results are compared to the simulation method is the same result.

  • PDF

헬리콥터 능동진동제어시스템 가속도 신호 처리 (Accelerometer Signal Processing for a Helicopter Active Vibration Control System)

  • 김도형
    • 한국항공우주학회지
    • /
    • 제45권10호
    • /
    • pp.863-871
    • /
    • 2017
  • 헬리콥터 능동진동제어시스템에 널리 이용되는 LMS (least mean square) 알고리즘은 전방경로 (forward path) 전달함수와 에러 신호의 연산을 통해 제어 입력을 계산한다. 에러 신호가 정현파 형태일 경우, 기준 신호에 동기화된 진동수, 위상을 가지는 코사인과 사인 함수의 조합으로 표현될 수 있다. 제어 신호 또한 동일한 진동수를 가지게 되므로 제어 입력의 코사인, 사인 성분의 크기만 계산하고, 기준 신호의 진동수, 위상 정보를 활용하면 제어알고리즘은 단순하게 구현될 수 있다. 제어 입력 신호의 계산은 단순한 행렬 연산으로 구현되고, 제어 명령의 변화는 에러 센서의 주파수에 비해 느리기 때문에 제어알고리즘은 낮은 주파수에서 운용 가능하다. 에러 센서의 코사인, 사인 성분을 추출하는 신호처리 알고리즘을 시뮬링크 모델로 구현하고, PIL (processor in the loop) 모드 시뮬레이션을 통해 실시간 작동 성능을 평가하였다.

퍼지 적응제어를 통한 도시교차로망의 교통신호제어 (Fuzzy Adaptive Traffic Signal Control of Urban Traffic Network)

  • 진현수;김성환
    • 대한교통학회지
    • /
    • 제14권3호
    • /
    • pp.127-141
    • /
    • 1996
  • This paper presents a unique approach to urban traffic network signal control. This paper begins with an introduction to traffic control in general, and then goes on to describe the approach of fuzzy control, where the signal timing parameters at a given intersection are adjusted as functions of the local traffic network condition and adjacent intersection. The signal timing parameters evolve dynamically using only local information to improve traffic signal flow. The signal timing at an intersection is defined by three parameters : cycle time, phase split, off set. Fuzzy decision rules are used to adjust three parameters based only on local information. The amount of change in the timing parameters during each cycle is limited to a small fraction of the current parameters to ensure smooth transition. In this paper the effectiveness of this method is showed through simulation of the traffic signal flow in a network of controlled intersection.

  • PDF