• 제목/요약/키워드: Control of temperature

검색결과 9,553건 처리시간 0.048초

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • 제4권2호
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

펠티어 소자를 이용한 알루미늄 판의 온도 제어 (Temperature Control of the Aluminum Plate using Peltier Element)

  • 전원석;방두열;최광훈;권대규;김남균;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.764-767
    • /
    • 2004
  • This paper present the temperature control of aluminum plate using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is asserted to Peltier element, it absorbs heat from low temperature side and emits to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with ON/OFF control scheme and fan ON/OFF. As the result of experiments, it is proper to act fan only while cooling duration and there exist a proper cooling current to drop temperature rapidly. It takes about 100sec to increase to 7$0^{\circ}C$ and drop to 35$^{\circ}C$ of aluminium plate temperature and about 90sec to increase to 7$0^{\circ}C$ and drop to 4$0^{\circ}C$ in ambient temperature 3$0^{\circ}C$ while fan is on only in cooling duration. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier element to heating and cooling.

  • PDF

텐덤형 냉방시스템의 안전운전을 고려한 압축기와 전자팽창밸브 제어 (Control of Compressors and Electronic Expansion Valve considering the Safe Operation of a Tandem-type Air-conditioning system)

  • 한도영;김재현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.675-680
    • /
    • 2006
  • Capacities of a tandem-type air-conditioner may be modulated by turning on and off of multiple compressors, and adjusting the position of a electronic expansion valve. In this study, control algorithms for compressors and a electronic expansion valve were developed by using fuzzy logics. The pressure control algorithm was also developed for the safe operation of compressors. There algorithms were implemented in a test lab and proved to be effective for the control of indoor air temperature and superheat temperature,

  • PDF

식품판매업소의 냉장.냉동 진열대의 온도 관리 조사연구 (A Survey of the Temperature Control of Refrigerators and Freezers in Retail Food Shops)

  • 김종규
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.161-171
    • /
    • 2002
  • The number of food establishments selling raw and convenience foods are increasing in Korea, and people enjoy purchasing and eating foods at these shops. However, there are only a few reports on the temperature control of the refrigerators and freezers at retail food shops. This study was performed to investigate the temperature control of refrigerators and freezers in retail food shops in Daegu. The survey was carried out from July 20 to August 30 in 2001. The trained surveyors visited the twenty retail food shops (four department stores, eight marts/supermarkets and eight convenience stores) in the 8 major areas of Daegu and inspected the temperature control of 48 refrigerators for dairy products, fruits & vegetables, and rolled rice & sandwiches, and 52 freezers for ice cream & sherbet, frozen food, and frozen fish. The percentage of the refrigerators, and freezers with unsafe temperatures higher than the recommended safe temperature (10℃ for refrigerators, and -18℃ for freezers) was 42%; 45.8% in refrigerators; 38.5% in freezers. On an average, the bigger the size of the shop, the better than the other freezers. On the other hand, the temperature control of refrigerator for fruits & vegetables was the worst because they were usually open. Actual temperatures in the refrigerators and freezers were found to be significantly higher than the reading on the thermometers attached to the refrigerators and freezers(p<0.05). These results indicate that temperature control of refrigerators and freezers at retail food shops should be monitored several times each day, and should have strict inspection. There should be more detailed legal standard and specification for temperature control of refrigerators and freezers at retail food shops to prevent foodborne illness from unsafely stored food.

개별공조시스템을 위한 전기히터의 PID 제어 (A PID Control of Electric Heater for PEM)

  • 장영준;박영칠;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF

복합 열원 공조시스템의 최적 제어 알고리즘 (Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

LED 조명 발열의 순차 제어시스템 연구 (Temperature Control for LED lamps using RF Communication)

  • 최형식;신희영;오지윤;이상섭
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.130-132
    • /
    • 2012
  • In this paper, a temperature control for LED(Light Emitting Diode) lamp using a cooling fan is studied. An efficient temperature control scheme for the LED lamp using the fan wind at the lowest sound noise is studied. For the study, after measurement of the minimum sound noise of the fan and related temperature of the LED lamp through tests, experiments on temperature control of the LED lamp using the fan with various size of heat sinks was performed. To minimize the fan sound noise, optimal size of the heat sink was studied. Also, a teleoperting control of LED lamps using RF communication was studied.

  • PDF

현대제어 이론을 이용한 냉동공조기의 정밀 온도제어 (Precise temperature control by modern control method on the refrigerator and air conditioner)

  • 한정만;유휘룡;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1213-1216
    • /
    • 1996
  • This paper describes a precise temperature control method for refrigerating and air conditioning systems. The control technique is based on the optimal servo control design method and the control algorithm is implemented on a personal computer. To control the precise temperature, two actuators such as an inverter for the compressor speed control and a stepping motor for regulating the expansion valve are used. The superheat and evaporator temperatures are chosen as the system output. So a multivariable system which has two inputs and two outputs to be controlled. The complicative model is identified by using an ARX(Auto Regressive eXogenous) model and the controller is designed by using the Matlab software.

  • PDF

PWM 제어방식에 의한 온열치료기의 새로운 온도제어 시스템 (A New Temperature Control System by PWM Control Method for Thermal Massage System)

  • 송명규;이재흥
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.409-419
    • /
    • 2014
  • 본 논문에서는 온열치료기의 온도제어 알고리즘 및 시스템을 구현하였다. PWM(Pulse Width Modulation) 파형의 온 타임 펄스폭을 제어함으로서 온열치료기의 마사지 기능에 적합한 온열요법이 내장된 안정된 온도제어를 구현 할 수 있었으며 의료기기의 온열마사지, 온열지압, 온열 뜸 기능에 적용 하였다. 온도설정 범위는 $40^{\circ}C$에서 $70^{\circ}C$까지이며 $5^{\circ}C$ 단위로 설정하였고 제어량은 실시간으로 $1^{\circ}C$ 단위로 제어하였으며 $1^{\circ}C$ 간격으로 온도를 표시하였다. 제어범위는 설정온도와 현재온도의 차가 $4^{\circ}C$이하부터 4단계로 PWM 펄스폭을 가변하여 램프의 출력을 제어하였다. 현재온도가 설정온도와 같을 경우 PWM 신호를 최소로 하였고 현재온도가 설정온도 보다 클 경우는 PWM 출력 신호를 정지시켜 오버헌팅을 방지했으며 연산차가 $4^{\circ}C$이상인 경우 PWM 제어량을 최대폭으로 하여 시스템을 빠른 상승시간 안에 목표치에 도달할 수 있도록 제어하는 방식으로 구현하였다.

관류형 보일러의 온도제어 (Temperature control for once through boiler)

  • 김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.900-904
    • /
    • 1991
  • It is important and difficult to control the steam temperature in the once through boiler. Generally, steam temperature of once through boiler not only is controlled by boiler spray water flow, but also is influenced by feed water flow and fuel flow. So we have to make the same gain of fuel flow controller and feed water flow controller. This paper is shown the design and test of steam temperature and feed water flow control system for once through boiler in pusan thermal power plant.

  • PDF