• Title/Summary/Keyword: Control of separation

Search Result 1,029, Processing Time 0.031 seconds

A Study on the Length of Electrical Separation Joint in AF Track Circuit (AF궤도회로에서 전기적 절연구간의 길이에 대한 연구)

  • Lee, Myung-Chul;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.70-75
    • /
    • 2013
  • The electrical separation joint as a filter circuit distributes the track circuit frequency. The electrical separation joint is classified into the interval where reinforcing bars are insulated and not insulated through the length of track circuit. In case of incorrectly setting up the length of electrical separation joint, the amplitude of current on the track circuit is not over standard current which is the standard of current on the track circuit and it effects on the close frequency on track circuit. Then, it makes an accident or makes a train not receive information for train control. In this paper, the electrical separation joint model is suggested and parameters are numerically calculated in the model. Moreover, the length of electrical separation joint is analyzed and is demonstrated by uisng Matlab and PSpice program.

Effect of separation walls on reduction of suspended solids loading in a combined sewer system (합류식 하수관거내 우오수분리벽 설치에 따른 부유물질 제어효과)

  • Kwon, Chungjin;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.787-796
    • /
    • 2012
  • The purpose of this study is to investigate CSOs(combined sewer overflows) control in the combined sewer with/without separation wall. There is the high correlation between sewage velocity and suspended solid(SS) loading in the sewer without it. The SS/BOD ratio was about 3 times in the area with it, while it was about 5 times in the area without it. Therefore, the accumulated deposit within the sewer has influenced high SS loading in the sewer without it. This study showed that the separation wall installed acquired an acceptable efficiency in controlling the accumulated deposit in the combined sewer. According to this study, the BOD control effect was about 38 % in the sewer with the separation wall, whereas it showed about 24 % in the sewer without it. In this case, it was anticipated that the high pollutant control effect would be expected if the separation wall was installed in the combined sewer.

Reducing Separation Force for Projection Stereolithography based on Constrained Surface Technique (규제액면기법의 전사방식 광조형 시스템을 위한 이형력 감소)

  • Kim, Hye Jung;Ha, Young Myoung;Park, In Baek;Kim, Min Sub;Jo, Kwang Ho;Lee, Seok Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.1001-1006
    • /
    • 2013
  • Projection-based stereolithography is divided into constrained-surface and free-surface type according to controlling liquid layer. The constrained-surface type has a uniform layer thickness due to the use of a projection window, which covers the pattern generator such as liquid crystal display. However, the adhered resin on the projection window causes trouble and requires great separation force when the cured layer is separated from the window. To minimize the separation force, we developed a system to measure the separation force. The influence of material covering the pattern generator and the resin temperature is investigated in the system. Several structures according to the resin temperature and the velocity of z-axis elevation are compared. As a result, the fabrication condition to minimize the separation force reduces the process time.

Model Following Reconfigurable Flight Control System Design Using Direct Adaptive Scheme (직접 적응기법을 이용한 모델추종 재형상 비행제어시스템 설계)

  • 김기석;이금진;김유단
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2003
  • A new reconfigurable model following flight control method based on direct adaptive scheme is presented. Using the timescale separation principle, both the inner-loop and the outer-loop states are controlled simultaneously. For the timescale separation assumption to be satisfied, the inner-loop model dynamics is set to be fast whereas the outer-loop model dynamics is set to be relatively slow. The stability and convergence of the proposed control law is proved by Lyapunov theorem. One of the merits of the proposed reconfigurable controller is that the FDI process and the persistent input excitation are not necessary, which is suitable for the flight control system. To evaluate the reconfiguration performance of the proposed control method, numerical simulation is performed using six degree-of-freedom nonlinear dynamics.

Control of the Sediment in a Combined Sewer Using a Separation Wall

  • Lim, Bong Su;Kwon, Chung Jin;Kim, Do Young;Lee, Kuang Chun
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • This study is to evaluate the effects of the separation wall on the sediment quality and quantity in a combined sewer, by surveying the sewer overflow and sediments during a rainfall. Since the separation wall installed in the combined sewer separates the rainfall and the sewage, the flow rate of the sewage is increased, and the amount of the sediment deposited on the sewer is decreased. One sampling point was the outfall of Daesacheon with a separation wall, and the other was the outfall of Gwaryecheon without a separation wall, in Daejeon metropolitan city. The maximum control of the biochemical oxygen demand (BOD) overflow load was more than 38% in the Daesacheon point with the separation wall, during a rainfall of 0.11 mm/hr. The maximum control of the BOD overflow load was 24% in Gwaryecheon without a separation wall, during a rainfall of 1.0 mm/hr. According to the survey results of the sediment in the sewer, the discharged sediment deposited on the sewer in Gwaryecheon point was about 23% to 28% of the total suspended solid during the rainfall. In addition, the average velocity of sewage in the presence of sediment was about 0.30 m/s, and if the separation wall is installed, it was expected to be about 1.01 m/s, that is 3.4 times more than the same conditions, resulting in the reduction of the sediment deposit.

Control of Nano-Structure of Ceramic Membrane and Its Application (세라믹 멤브레인의 나노구조 제어 및 응용)

  • Lee, Hye-Ryeon;Seo, Bong-Kuk;Choi, Yong-Jin
    • Membrane Journal
    • /
    • v.22 no.2
    • /
    • pp.77-94
    • /
    • 2012
  • Amorphous ceramic membranes have been developed for gas phase separation and liquid phase separation (water treatment, wastewater treatment and separation of organic solvent or compounds) because of their thermal stability and solvent resistance. In this paper, ceramic membranes were categorized by membrane pore size and materials, and summarized for hydrogen separation, carbon dioxide separation, membrane reactor, pervaporation and water treatment with membrane structure and properties.

Competitive Phase Separation in a Crystallizable Polymer Solution

  • Lee, Hwan-Kwang
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.12-17
    • /
    • 1996
  • The structure formation by liquid-liquid(L-L) phase separation coupled with crystallization in isotactic polypropylene(i-PP). solutioos was investigated by a temperature jump experiment. A series of dialkyl phthalates with a different number of carbon atoms in the alkyl chain was used to control the interaction between polymer and solvent. Various thermal quench conditions were applied to the i-PP solutions to control systematically L-L phase separation and crystallization. A slow crystallizatina elongates the liquid droplets in the radial direction of a spherulite. A rapid crystallization under the deep quench locks-in the growth of L-L phase separation. These results indicate that the extent of L-L phase separation which exists below melting point can be successfully controlled through the proper selection of solvent and thermal conditions.

  • PDF

Manipulation of Single Cell for Separation and Investigation

  • Arai, Fumihito;Ichikawa, Akihiko;Maruyama, Hisataka;Motoo, Kouhei;Fukuda, Toshio
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.135-143
    • /
    • 2004
  • Recently, high throughput screening for microorganisms with desired characteristics from a large heterogeneous population has become possible. Single cell separation has taken on increasing significance in recent years, and several different methods have been proposed so far. In this paper, we introduce several cell manipulation methods aiming at single cell separation and investigation. At first, methods for the separation of microorganisms are classified. Then, we introduce two different approaches, that is, (1) indirect manipulation using laser trapped microtools and (2) thermal gelation.

On the Separation Principle of Takagi-Sugeno Fuzzy Systems (Takagi-Sugeno 퍼지 시스템의 분리 원리에 관하여)

  • 이호재;박진배;주영혼
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09b
    • /
    • pp.80-83
    • /
    • 2003
  • In this note, a separation principle of the Takagi-Sugeno (T-S) fuzzy-model-based controller/observer is investigated. The separation principle of T-S fuzzy-model-based controller/observer sharing the premise parts in the fuzzy rule with directly measurable premise variables is well established. In that case, the fact that the augmented observer-based control system has the eigenvalues of the sub-closed-loop control system by the state-feedback controller and the sub-closed-loop observer error system is used to prove the separation principle. This paper studies the separation principle of T-S fuzzy-model-based controller/observer in which the premise variables cannot be directly measurable.

  • PDF

A Study of the Influence of the Injection Location of Supersonic Sweeping Jet for the Control of Shock-Induced Separation (경사충격파 박리유동 제어를 위한 초음속 진동제트 분출위치의 영향성 연구)

  • Park, Sang-Hoon;Lee, Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.747-754
    • /
    • 2022
  • An experimental study was carried out to control a shock-induced boundary layer separation by utilizing the supersonic sweeping jet from the fluidic oscillator. High-speed schlieren, surface flow visualization, wall pressure measurement and precise Pitot tube measurement were applied to observe the influences of the location and the supply pressure of the fluidic oscillator on the characteristics of the oblique-shock-induced boundary layer separation. The characteristics of the separation control by the present supersonic fluidic oscillator was quantitatively analyzed by comparing with a conventional control method utilizing an air-jet vortex generator.