• 제목/요약/키워드: Control of exposure

검색결과 2,685건 처리시간 0.032초

방사선의 반복조사가 랫드 림프구의 염색체이상과 자매염색분체교환에 미치는 영향 (The Effects of Fractionated Radiation on Chromosome Aberrations and Sister Chromatid Exchanges in Rat Lymphocyte Culture)

  • 이명구;이광성;조영채
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.88-99
    • /
    • 1998
  • This study was undertaken to find out the bio-effects due to be a radiation fractionated exposure. The experimental animals were divided into the control group and the radiation exposure groups of 20cGy, 40cGy and 80cGy with 220 male Sprague-Dawley rats at 6 weeks old. The radiation exposure groups were fractionated exposed from each 20cGy, 40cGy and 80cGy for every 5 days. The chromosome aberrations, the frequency of SCE, the changes of body weight, hematological values and enzyme activities were investigated for the fractionating exposure times and the time after fractionated exposure. The results were summarized as follows 1. The body weight of the radiation exposure groups were significantly decreased compared with control group according to the increasing fractionated exposure times, and it was the lowest values at the immediately after the end of the fractionating exposed, but it was recovered with the level of control group at 3rd weeks gradually increased 1st week after fractionated exposure. 2. The values of WBC, RBC, Hb and Hct in the radiation exposure groups were significantly decreased than those the control group, but the values of GOT, GPT, ALP, and LDH in the radiation exposure groups were significantly increased than those of the control group. 3. The frequency of chromosomal aberration were increased according to the increasing fractionated exposure dose, and it showed the highest at 5th days after fractionated exposed. The types of chromosomal aberration were occurred such as a numerical abnormality, deletion, break and duplication, it was not recovered immediately and maintained high frequency than the control group. 4. The frequency of SCE were significantly increased according to the increasing fractionated exposure dose in 20cGy, 40cGy and 80cGy groups. But it was recovered the level of control group at 7th days after fractionated exposure. According to the above results, this study could confirm that the frequency of chromosomal aberration and SCE were increased with fractionated exposure dose, the other hand, the changes of body weight, hematological values and enzyme activity values were significantly affected according to the increasing fractionated exposure dose.

  • PDF

BENZENE AND LEUKEMIA An Epidemiologic Risk Assessment

  • Rinsky Robert A.;Smith Alexander B.;Hornung Richard;Filloon Thomas G.;Young Ronald J.;Okun Andrea H.;Landrigan Philip J.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(환경)
    • /
    • pp.651-657
    • /
    • 1994
  • To assess quantitatively the association between benzene exposure and leukemia, we examined the mortality rate of a cohort with occupational exposure to benzene. Cumulative exposure for each cohort member was estimated from historical air-sampling data and, when no sampling data existed, from interpolation on the basis of existing data. The overall standardized mortality ratio (a measure of relative risk multiplied by 100) for leukemia was 337 (95 percent confidence interval, 154 to 641), and that for multiple myeloma was 409 (95 percent confidence interval, 110 to 1047). With stratification according to levels of cumulative exposure, the standardized mortality ratios for leukemia increased from 109 to 322, 1186, and 6637 with increases in cumulative benzene exposure from less than 40 parts per million-years (ppm-years), to 40 to 199, 200 to 399, and 400 or more. respectively. A cumulative benzene exposure of 400 ppm years is equivalent to a mean annual exposure of 10 ppm over a 40-year working lifetime; 10 ppm is the currently enforceable standard in the United States for occupational exposure to benzene. To examine the shape of the exposure-response relation, we performed a conditional logistic-regression analysis, in which 10 controls were matched to each cohort member with leukemia. From this model, it can be calculated that protection from benzene induced leukemia would increase exponentially with any reduction in the permissible exposure limit.

  • PDF

체중조절행동과 신체노출 의복행동 상관연구 (The Effect of Body Cathexis, Weight Control Behavior on Clothing Behavior)

  • 이영주;임숙자
    • 한국의류학회지
    • /
    • 제26권11호
    • /
    • pp.1491-1501
    • /
    • 2002
  • The purpose of this study was to set up an effective marketing strategy targeting college women by researching the relationship between weight control behavior and body exposure in clothing behavior. The results showed that 1) 85.5% of the college women participated in weight control behavior, and 53.5% of them wanted to lose more than 3kg of their weight. 2) College women were less satisfied with their body and thar showed less body exposure in clothing behavior according to the increase of weight control degree. The weight control parts and unsatisfied body parts were almost matched : thigh, abdomen, hip, calf, and weight. College women preferred clothing that exposed neck, legs and shoulder more than clothing that exposed many parts of their body at the same time. 3) exposure in clothing decreased according to the increase of weight control degree, except for the exposure of breast in clothing.

디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가 (Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR))

  • 최지안;황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권8호
    • /
    • pp.276-283
    • /
    • 2019
  • 본 연구는 자동노출제어장치(Automatic Exposure Control, AEC)와 수동노출 이용 시 입사표면선량(Entrance Surface Dose, ESD)과 Entropy를 분석하여 자동노출제어장치의 유용성에 대해 알아보고자 하였다. 실험방법은 Skull, Chest, Abdomen, Pelvis 부위에 대하여 란도팬텀(Rando Phantom)에 반도체 선량계를 위치시켜 선량을 측정하였고, 동시에 획득한 DICOM(Digital Imaging and Communications in Medicine) 파일을 Matlab으로 Entropy 분석을 하였다. 그 결과 자동노출제어장치 이용 시 모든 부위의 입사표면선량이 수동노출보다 낮았고 Entropy 수치는 높았으며, paired t-test는 p<0.05로 유의한 차이가 있음을 알 수 있었다. 결론적으로 자동노출제어장치의 사용은 X선 검사 시 발생할 수 있는 불필요한 방사선량과 정보의 손실량을 줄여서 피폭선량과 영상 화질의 최적화에 기여할 수 있는 유용한 방법이 될 수 있다.

일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구 (A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin)

  • 박동욱;신용철;이나루;이광용;오세민;정호근
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF

방사선 영상 매핑 장치 (Radiation image mapping system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

Nonylphenol의 장기간 노출에 의한 붕어, Carassius auratus의 생식지표 변화 (Change of Reproductive Indicator of the Crucian Carp, Carassius auratus (Teleostei:Cyprinidae) Long-term Exposed to Nonylphenol)

  • 조남국;진영국;이철우;김현미;최경희;정규혁;강주찬;이정식
    • Environmental Analysis Health and Toxicology
    • /
    • 제22권3호
    • /
    • pp.235-245
    • /
    • 2007
  • Toxicity of nonlyphenol (NP) one of EDCs was studied with focus on reproduction of the crucian carp, Carassius auratus. Fishes were cultured under control and nonylphnol exposure conditions for 32 weeks. Experimental group was composed of total of 4 groups, 1 control condition and 3 nonylphenol exposure condition ($18\;{\mu}g\;NP\;L^{-1},\;37\;{\mu}g\;NP\;L^{-1}\;and\;83\;{\mu}g\;NP\;L^{-1}$). Survival rate was found to be similar in control and $18\;{\mu};NP\;L^{-1}$. However, it is lower In the $37\;{\mu};NP\;L^{-1}$ and $83\;{\mu};NP\;L^{-1}$ in comparison to the control group. Deformation of gonads was the highest in the exposure condition of $18{\mu};NP\;L^{-1}$ with the female illustrating higher ratio than the male. GSI was not much different in the male but in the female, NP exposure group illustrated lower value compared to the control group. HSI and GI did not illustrate any clear differences between the control and exposure group for both male and female. Intersex was 0% in the wild group, 4.16% in the laboratory control group, and 25.67% in the NP exposure condition with female illustrating higher compared to male. Concentration of blood vitellogenin in female illustrated no clear differences between the control and NP exposure group. However, in the male, it was higher in the NP exposure group in comparison to the control group, and illustrated higher values of vitellogenin compared to the figures found in the female of same con-centration condition.

Today's Nuclear Challenge: Maintenance and Radiation Exposure

  • Willis, Chales A.
    • Nuclear Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.159-165
    • /
    • 1975
  • The Nuclear power industry today faces a serious and rapidly emerging problem in reactor maintenance and occupational radiation exposure control. The basic problem is the need for much maintenance on nuclear power plants. The problem is seriously compounded by radiation exposure control requirements. Many studies are underway seeking solutions tut the industry is developing rapidly and new plants will not await the results of such studies. It is essential that attention be given to maintenance and exposure control in all phases of plant design, construction and operation.

  • PDF

VME bus를 이용한 Step & Scan형 노광장비의 Control System 구성 (VME bus based control system for step & scan exposure tool)

  • 최용만;오병주;김도훈;정해빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.672-675
    • /
    • 1997
  • This paper proposes a structure of the control system for the step & scan exposure tool. The step & scan exposure tool is used for the manufacturing process of the semiconductor DRAM memory of giga bit. The control system employs the VME bus instead of the conventional ISA bus so that all control signals and data can be managed separately by the 4 VME-PCs for fast and fault-free flow of signals for multi-tasking. A high speed I/O card is equipped for the real-time monitoring and control of the sub module equipment. Then all the subsystems are integrated and aligned for the operation of the step & scan exposure tool with the VME bus and, I/O card.

  • PDF

이온화방사선 피폭에 의한 골수세포의 Ornithine Decarboxylase 활성도의 변화에 대한 전계장의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Electric Field the Ornithine Decarboxylase Activity Change of Myeloid Cells According to Ionizing Radiation Exposure)

  • 정문호
    • 한국환경보건학회지
    • /
    • 제21권1호
    • /
    • pp.78-85
    • /
    • 1995
  • Ornithine decarboxylase(ODC) is an indicate enzyme in carcinogenesis. We divided Sprague Dawley rats into six groups: control, electric field exposure, X-ray only irradiation, X-ray irradiation with electric field exposure group, Sr-90 injected group and Sr-90 and electric field complex exposure group. The ODC activity was measured in rat's bone marrow cell every week. The results were summarized as follows: The ODC activitied was increased in X-ray irradiated, Sr-90 injected and Sr-90 and electric field complex exposed group as compared with that of control(p<0.05). The ODC activity was increased comparing that of control neither in X-ray and electric field complex exposed group nor electric field only exposed group. This result suggests that the electric field doesn't have myeloid carcinogenicity and myeloid cancer incidence caused by ionized radiation is suppressed by electric field exposure.

  • PDF