• Title/Summary/Keyword: Control malfunction

Search Result 238, Processing Time 0.03 seconds

A Experimental Study to Diagnose of Air Operated Valve (공기구동 밸브 진단을 위한 동적특성의 실험적 고찰)

  • Yang S.M.;Hong S.D.;Song D.S.;Park J.K.;Shin S.K.;Lee H.Y.;Yang S.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1766-1769
    • /
    • 2005
  • Air-operated valve(AOV) is one of principal valves that are using to control fluid flow in nuclear power plants. AOV is suffered from damage and malfunction by the abrasion, corrosion and vibration of valve parts under the long time operation. This mechanical trouble and malfunction of valve is critical for the safety of power plant. So a periodic diagnosis for safety of power plants is inevitable to guarantee the safety of the power plant. But depending on the type of the actuator and valve body, various types of AOV exist. In this study, It is developed the diagnostic system that users of power plants are easy to handle in this paper.

  • PDF

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

A Study on the Countermeasure Algorithm for Power System Disturbances in Large Scale Fuel Cell Generation System (대용량 연료전지시스템의 계통외란 방지알고리즘에 관한 연구)

  • Choi, Sung-sik;Kim, Byung-ki;Park, Jae-beom;Rho, Dae-seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.711-717
    • /
    • 2016
  • Recently, fuel cell generation system with high energy efficiency and low CO2 emission is energetically interconnected with distribution power system. Especially, MCFC(molten carbonate fuel cell) operating at high temperature conditions is commercialized and installed as a form of large scale power generation system. However, it is reported that power system disturbances such as harmonic distortion, surge phenomenon, unbalance current, EMI(Electromagnetic Interference), EMC (Electromagnetic Compatibility) and so on, have caused several problems including malfunction of protection device and damage of control devices in the large scale FCGS(Fuel Cell Generation System). Under these circumstances, this paper proposes countermeasure algorithms to prevent power system disturbances based on the modelling of PSCAD/EMTDC and P-SIM software. From the simulation results, it is confirmed that proposed algorithms are useful method for the stable operation of a large scale FCGS.

The Toxic Effect Of Marine V. Vulnificus Endotoxin OH the Blood Component in Rat (해양 V. vulnificus의 내독소가 rat의 혈액 성분에 미치는 독성 효과)

  • 이봉헌
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.69-73
    • /
    • 1997
  • Endotoxin from the cell wall of marine V. vujnificus was .extracted using the hot phenol-water method, injected endotoxin into rat, and tested the toxic effect of endotoxin on the blood component In rat blood. The results showed that blood glucose, blood urea nitrogen, white blood cell, and reticulocyte were Increased and red blood cell was the same as the number of control group(normal blood), but platelet was decreased. Above results suggested that endotoxin induced a malfunction of liver and that the Increase of white blood cell was for the removal of foreign toxic substance.

  • PDF

Modular Backpropagation Network to Diagnosing Plasma Processing Equipment

  • Kim, Byungwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.5-32
    • /
    • 2002
  • Processing plasmas are playing a crucial role in either depositing thin films or etching fine patterns. Any variability in process factors (such as radio frequency power or pressure) can cause a significant shift in plasma state. When this shift becomes large enough to change operating condition beyond an acceptable level, overall product quality can greatly be jeopardized. Thus, timely and accurate diagnosis of plasma malfunction is crucial to maintaining device yield and throughput. Many diagnostic systems have been developed, including HIPOCRATES [1] and PIES [2]. Plasma equipment was also diagnosed by combining neural network and expert system called Dempster-Schafer Theory [3]. A fact c...

  • PDF

Development of Gas Treatment System for Passenger Cabins (객차용 가스처리장치 개발)

  • Lee, Ju-Yeol;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1302-1306
    • /
    • 2007
  • Malfunction or inappropriate management of ventilation system in public transportation may cause unpleasant atmosphere or health problems to the old or feeble passengers. In this work, adsorption/desorption system for gaseous carbon dioxide is developed and tested under the various indoor conditions. Finally an optimum design specification for the indoor $CO_2$ control will presented.

  • PDF

FUZZY METHOD FOR FINDING THE FAULT PROPAGATION WAY IN INDUSTRIAL SYSTEMS

  • Vachkov, Gancho;Hirota, Kaoru
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1114-1117
    • /
    • 1993
  • The paper presents an effective method for finding the propagation structure of the real origin of a system malfunction. It uses a combined system model consisting of Structural Model (SM) in the form of Fuzzy Directed Graph and Behavior Model (BM) as a set of Fuzzy Relational Equations $A\;{\circ}\;R\;=\;B$. Here a specially proposed fuzzy inference technique is checked and investigated. Finally a test example for fault diagnosis of an industrial system is given and analyzed.

  • PDF

A study on the development of satellite dynamic simulator hardware (위성체 성능 시험 장치 개발에 관한 연구)

  • 용상순;김영학;김진철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.788-792
    • /
    • 1993
  • The objective of this study is to develope a satellite dynamic simulator, which can test and analyze the performance of spacecraft attitude control, antenna pointing instruments, communication equipments and spacecraft components under the space environment. The satellite simulator can be used to predict the events such as malfunction and failure of satellites in space during operation and can be used to protect against emergencies. At first, the performance test system of attitude control is investigated which can simulate motion and verify stability of spacecraft. Our system consists of an attitude control main processor and a sub-processor including some real hardwares such as attitude sensors and actuators. In this paper, we describe the procedure of designing and manufacturing the dynamic simulator hardware, which consists of the central processor board, the sub-processor board and the sun sensor, and also communication between the components.

  • PDF

The study of sensor malfunction detection and conversion to Sensorless control when the failure of rotational speed sensor is occurred (풍력발전기의 회전속도센서 고장 검출 및 Sensorless 제어로의 운전 전환 연구)

  • Oh, Joongki;Choi, Wonsik;Park, Kihyun;Park, Hyunchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.183.1-183.1
    • /
    • 2010
  • 본 논문에서는 풍력발전기의 회전속도센서의 고장 발생 시 고장을 검출하고 회전속도센서의 사용 없이 Sensorless 제어로의 전환에 관한 연구를 기술하였다. 최근 풍력발전은 급속한 성장함에 따라 풍력발전기의 대형화 및 해상풍력화 추세에 있다. 특히 해상풍력발전은 바람 및 설치장소의 제약에서 벗어나는 이점에 반해 염해, 습도 및 파도에 의한 진동 발생으로 센서의 고장 발생률이 높을 것으로 예상된다. 이에 따라 풍력발전기의 회전속도센서 고장 발생 시 이를 검출하는 방법을 제시하였다. 또한 회전속도센서의 고장이 검출되면 회전속도센서를 이용한 풍력발전기 제어방식에서 Sensorless 제어로의 전환을 통해 안전하게 풍력발전기를 운전할 수 있도록 하였다. 연구된 제어기법은 PSIM을 이용한 시물레이션을 통해 결과를 검증하였다.

  • PDF

Surge Immunity Performance Enhancement Techniques on Battery Management System (전지관리장치(BMS)의 서지내성 성능향상 기법)

  • Kim, Young-Sung;Rim, Seong-Jeong;Seo, Woohyun;Jung, Jeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.