Abstract
Air-operated valve(AOV) is one of principal valves that are using to control fluid flow in nuclear power plants. AOV is suffered from damage and malfunction by the abrasion, corrosion and vibration of valve parts under the long time operation. This mechanical trouble and malfunction of valve is critical for the safety of power plant. So a periodic diagnosis for safety of power plants is inevitable to guarantee the safety of the power plant. But depending on the type of the actuator and valve body, various types of AOV exist. In this study, It is developed the diagnostic system that users of power plants are easy to handle in this paper.