• 제목/요약/키워드: Control link

검색결과 2,426건 처리시간 0.028초

유연성 로봇 매니퓰레이터에 대한 비선형 가변구조제어 (Nonlinear variable structure system control for flexible link robot manipulators)

  • 김성태;임규만;함운철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.280-284
    • /
    • 1997
  • In this paper, Nonlinear VSS control based on bang-bang control concept is derived under the assumption that the control input is bounded. We try to derive control algorithm which has almost same performance as the time optimal control. We focus this control scheme on the real implementation of DC motor position controller of flexible link, i.e. we obtain the switching curves from the real data of DC motor system operating under the full maximum and minimum applied voltages. State space is separated into several regions and we set different switching surfaces in each region to reduce chattering problem. The efficiency of the proposed controller is compared with PID controller and it is shown that the controller converges fast than PID controller without chattering. The hybrid controller scheme is also proposed not only to control the position of hub but also to reduce the vibration of end tip of flexible link.

  • PDF

BLDC Motor Control System using ASK DC-link PLC Technology

  • Yu, Tao;Song, Sung-Geun;Kim, Se-Min;Kim, Kwang-Heon;Park, Sung-Jun
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.45-52
    • /
    • 2009
  • Power line communication or power line carrier (PLC) is a system for carrying data on a conductor and can also used for electric power transmission. Now the powers used in the motor drive system are mostly DC sources. Even AC powers in some systems are generated from DC sources by the inverter. It is can be forecasted that the DC-link PLC technology will be widely used in various industrial fields. In this paper a novel BLDC motor control system using ASK DC-link PLC technology is proposed. The characteristic of this system is that the communication only needs 2 DC lines and there are no additional lines to translate the reference signals. The number of signal cables can be minimized when the DC-link PLC method is applied in the multi motor control system and the slip ring design also can be simplified when this method is applied in rotation machines. The proposed motor control system is clarified by the PSIM and MATLAB simulations and tested through the hardware prototype.

2-링크 유연한 로보트 팔에 대한 적응제어 (Adaptive control for two-link flexible robot arm)

  • 한종길;유병국;임규만;함운철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.8-13
    • /
    • 1993
  • This paper presents deterministic and adaptive control laws for two-link flexible arm. The flexible arm has considerable structural flexibility. Because of its flexbility, dynamic equations are very complex and difficult to get, dynamic equations for two-link flexible arm are derived from Bernoulli-Euler beam theory and Lagrangian equation. Using the fact that matrix is skew symmetric, controllers which have a simplified structure with less computational burden are proposed by using Lyapunov stability theory.

  • PDF

전력 품질 향상을 위한 배전용 STATCON의 AC전압, 직류결합 전압 및 고조파 보상 제어알고리즘 개발 (The Development of Control Algorithms of D-STATCON for Compensations of AC Voltage and DC Link Voltage and Harmonics Improve the Qeality of Electric Power)

  • 오관일;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.333-337
    • /
    • 1999
  • This paper presents the DQ transfomation space space vector modulation method to devel control algorithm of distribu STATCON(STATic CONdenser) for line volt regulation, dc link voltage regulation harmonics compensation. The Performance an of a PI with ramp comparision and synchro reference frame current controller is carried Based on these analysis, the control perform are desirable to compensate the harmonics a regulate dc link and line voltage of Distrib line.

  • PDF

직류송전에서 과도응답특성 개선을 위한 컨버터의 제어 (New Control Method of Converter to Improve Transient Response in HVDC Link System)

  • 민완기;유명호;김영한;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.342-344
    • /
    • 1996
  • This paper describes the usefulness of new control method in HVDC link system which suffers from severe condition of weak ac system. The proposed control scheme is used for the positive feedback control which directly controlls dc current at dc link system. The object of this paper is to improve the transient response of HVDC link system in disturbances such as faults. To achieve this objective, digital time-domain simulations are employed by the Electro Magnetic Transient Program for DC system(EMTDC).

  • PDF

Start-Up Current Control Method for Three-Phase PWM Rectifiers with a Low Initial DC-Link Voltage

  • Gu, Bon-Gwan;Choi, Jun-Hyuk;Jung, In-Soung
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.587-594
    • /
    • 2012
  • When a PWM rectifier has a low DC-link voltage during startup, the output voltage vector cannot be high enough to regulate the input current. This lack of a PWM rectifier output voltage vector can cause an unregulated inrush current when the rectifier operation starts. This paper presents a PWM rectifier start-up current control algorithm for when it starts operation with a lower DC-link voltage than unloaded condition case. To avoid the unregulated inrush current caused by a lack of DC-link voltage, the proposed control scheme regulates the one phase current with one switch chopping and it generates the current command considering the uncontrolled current magnitude information, which is calculated in advance. Simulation and experiment results support the validity of the proposed method.

Tip Position Control of a Flexible-Link Manipulator with Neural Networks

  • Tang Yuan-Gang;Sun Fu-Chun;Sun Zeng-Qi;Hu Ting-Liang
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.308-317
    • /
    • 2006
  • To control the tip position of a flexible-link manipulator, a neural network (NN) controller is proposed in this paper. The dynamics error used to construct NN controller is derived based on output redefinition approach. Without the filtered tracking error, the proposed NN controller can still guarantee the closed-loop system uniformly asymptotically stable as well as NN weights bounded. Furthermore, the tracking error of desired trajectory can converge to zero with the proposed controller. For comparison an NN controller with filtered tracking error is also designed for the flexible-link manipulator. Finally, simulation studies are carried out to verify the theoretic results.

자동차용 컨트롤 링크 업셋 용접부의 용접성 및 피로강도 향상에 관한 유한요소 해석 (Finite Element Analysis on Welded Part of control Link for Automobile)

  • 조해용;권혁홍;이봉규
    • 한국공작기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.63-70
    • /
    • 2001
  • This study is concerned with Finite Element Analysis on welded part of control link fur automobile. For analysis, control link was modeled into two parts, ring and rod. Heating condition, temperature distributions and fatigue fracture strength were analyzed using "HEAT III" and "NDURE" module of NISA II. Metal flow in the process of welding was simulat- ed by $DEFORM^{TM}2D$.The analyzed results were compared with experimental inspection. Quality of welded part was able to be improved by controlling metal flow in the process of welding by increase the friction constant of ring part. Heat transfer analysis and flow simulations were in good agreement wish welding experiments.

  • PDF

A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverter at Low Modulation Index

  • C.S. Ma;Kim, T.J.;D.W. Kang;D.S. Hyun
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.205-214
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM (DPWM) to balance the DC-link voltage of three-level neutral-point-clamped (NPC) inverter at low modulation index. It introduces new DPWM methods in multi-level inverter and one of them is used for balancing the DC-link voltage. The current flowing in the neutral point of the DC-link causes the fluctuation of the DC-link voltage of the NPC inverter. The proposed DPWM method changes the path and duration time of the neutral point current, which makes the overall fluctuation of the DC-link voltage zero during a sampling time of the reference voltage vector. Therefore, by using the proposed strategy, the voltage of the DC-link can be balanced fairly well and the voltage ripple of the DC-link is also reduced significantly. Moreover, comparing with conventional methods which have to perform the complicated calculation, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by the experiment.