• 제목/요약/키워드: Control facilities

검색결과 2,213건 처리시간 0.029초

서울지역 학교급식 위생관리 수행수준 평가 (Assessment of Food Safety Management Performance for School Food Service in the Seoul Area)

  • 이진현;고유경;박기환;류경
    • 대한지역사회영양학회지
    • /
    • 제12권3호
    • /
    • pp.310-321
    • /
    • 2007
  • Effective and systematic sanitation management programs are necessary to prevent foodborne disease outbreaks in school foodservice operations. The purpose of this study was to identify the elements to improve in order to ensure the safety of school food service by evaluating sanitation management practices implemented under HACCP-based programs. The survey was designed to assess the level of hygiene practices of school food service by using an inspection checklist of food hygiene and safety. Fifty-four school foodservice establishments considered as poor sanitation practice groups from two year inspections by Seoul Metropolitan Office of Education were surveyed from September to December in 2005. Inspection checklists consisted of seven categories with 50 checkpoints; facilities and equipment management, personal hygiene, ingredient control, process control, environmental sanitation management, HACCP system and safety management. Surveyed schools scored $68.0{\pm}12.42$ points out of 100 on average. The average score (% of compliance) of each field was 10.7/20 (53.3%) for facilities and equipment management, 7.4/11 (67.2%) for personal hygiene, 7.4/11 (74.1%) for ingredient control, 22.4/32 (69.8%) for process control, 8.9/12 (73.8%) for environmental sanitation management, 4.2/7 (59.7%) for HACCP systems management, and 7.2/8 (89.7%) for safety management, respectively. The field to be improved first was the sanitation control of facilities and equipment. The elements to improve this category were unprofessional consultation for kitchen layout, improper compartment of the kitchen area, lacks of pest control, inadequate water supply, poor ventilation system, and insufficient hand-washing facilities. To elevate the overall performance level of sanitation management, prerequisite programs prior to HACCP plan implementation should be stressed on the school officials, specifically principals, for the integration of the system.

국내 다이옥신 측정분석기관 지정 및 정도관리 (Certification and Quality Control of the Official Test Facilities of Dioxins in Korea)

  • 장성기;김태승;이원석;정영희;최덕일
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.675-682
    • /
    • 2000
  • 생활폐기물 처리용량이 일일 50톤 이상인 소각시설에 대한 배출가스중의 다이옥신 농도는 신규시설인 경우 $0.1ng-TEQ/Nm^3$, 기존시설인 경우 $0.5ng-TEQ/Nm^3$로 규제하고 있으며, 기존시설인 경우에도 2003년에는 $0.1ng-TEQ/Nm^3$로 강화할 예정이다. 이들 소각시설은 다이옥신 측정분석기관으로부터 년 2회 이상 배출가스중의 다이옥신 농도를 측정하여야 한다. 현재까지 7개 기관이 다이옥신 측정분석기관으로 지정을 받았으며, 이들 기관은 매년 국립환경연구원이 제공하는 정도관리 프로그램에 따라 평가를 받아야 한다. 1999년에는 1998년에 지정받은 4개 기관에 대하여 M 소각시설에서 대기오염공정시험방법에 따라 다이옥신 시료채취 및 분석을 하여 정도관리를 실시하였다. 정도관리 실시결과 등속흡인계수는 각각 100.9%, 102.4%, 102.1%, 99.2%로 4기관 모두 양호하였으며, 분해능 (10,000 이상), 질량검정 결과(${\pm}5ppm$ 이내), 동위원소 존재비 (15% 이내) 및 회수율(50-120%) 모두 대기오염공정시험방법 기준을 만족하였다.

  • PDF

개인고속이동시스템의 차량제어 알고리즘에 대한 실험적 평가 (An Experimental Evaluation of the Vehicle Control Algorithm in Personal Rapid Transit System)

  • 이준호
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1770-1774
    • /
    • 2007
  • In this paper we deal with a design of the evaluation system to assess the vehicle operational control algorithm for Personal Rapid Transit(PRT) system. PRT system is different from the conventional rail traffic system in such that the station is off-line so as to guarantee a very short headway. In this study we propose an evaluation system to assess the performance of the proposed vehicle control algorithm. The evaluation system is composed of virtual vehicles, central control system, virtual wayside facilities, monitoring equipments. The virtual vehicles are made up by the laptop computers and the central control system employs Power PC process of Motorola Inc. The wayside facilities are implemented by employing the PXI module of the National Instruments Corporation. In order to test the proposed evaluation system a test algorithm is used, which has been simulated in the combined simulation system between Labview Simulation Interface Toolkit and Matlab/Simulink.

첨단기술산업 시설물의 미진동제어를 위한 스마트 면진플랫폼의 적용 (Application of Smart Isolation Platform for Microvibration Control of High-Tech Industry Facilities)

  • 김현수;강주원;김영식
    • 한국공간구조학회논문집
    • /
    • 제14권2호
    • /
    • pp.87-94
    • /
    • 2014
  • In this study, a smart isolation platform has been developed for control of microvibration of high-technology facilities, such as semi-conductor plants and TFT-LCD plants. Previously, microvibration control performance of a smart base isolation system has been investigated. This study compared microvibration control performance of a smart isolation platform with that of conventional base isolation and fixed base. For this purpose, train-induced ground acceleration is used for time history analysis. An MR damper was used to compose a smart isolation platform. A fuzzy logic controller was used as a control algorithm and it was optimized by a multi-objective genetic algorithm. Numerical analysis shows that a smart isolation platform can effectively control microvibration of a high-technology facility subjected to train-induced excitation compared with other models.

양돈시설 내부의 악취조졸에 관한 기술 및 연구동향 (A Review of the Odor Control From Inside of Swine Production Facilities)

  • 김두환;김인배
    • 한국축산시설환경학회지
    • /
    • 제5권3호
    • /
    • pp.203-216
    • /
    • 1999
  • Recent public concern about air pollution caused by swine production facilities has forced to develop the methods to reduce and control the swine odors. Swine odors were affected the life of pig farm neighborhoods, swine productivity, pig health, diseases, and human right, safety, sanity as negatively. The first approaches of control of swine odors are the change or improve of the classical management systems, which are manure treatment method, manure storage facility, phase feeding, sex-divided feeding, feeder type, liquid-slurry feeding, environment control of swine building and dust control of indoor swine facility. The methods to control odor emission from manure have to include the diet modification as nutritional basis. In recent, research emphasis has focused on manipulating the swine diet to increase the nutrient utilization of the diet to reduce excretion products and reduction of odors. There are lots of feed additives and pit additives introduced as practical basis for reducing odor emissions. The ozone treatment method is candidate as the good system for reducing swine odor. But this system is still too expensive to practice in present.

화학물질 취급시설의 안전관리 합리화 방안 연구: 건축물 내화기준 중심 (A study on the Rationalization of Safety Management in Chemical Facilities: Focused on Architecture Fire Resistance Standards)

  • 이은별;유병태
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.91-97
    • /
    • 2019
  • 국내 화학물질 안전관리는 환경부의 화학물질관리법이 기본이 되어 관리되고 있다. 그 중에서도 취급시설의 설치 및 관리기준을 강화하여 관리하고 있는데, 타 법과의 상충, 시설 규모 및 물질 특성 미반영 등으로 인한 문제점들이 노출되었다. 본 연구에서는 이러한 취급시설 기준 중 건축물 내화기준에 대해 보다 현실적이면서 합리적인 개선 방안을 마련하고자 하였다. 이를 위해 국내 유사 화학물질 취급시설 안전관리 법령의 건축물 내화기준을 비교하였으며, 환경부 화학물질안전원 국민신문고를 통해 접수된 취급시설 기준 관련 민원 2220건 중 대표 민원 사례를 통해 주요 문제점을 파악하였다. 마지막으로 화학물질관리법상 취급시설의 규모와 물질의 종류를 구체화하여 건축물 내화기준을 적용하는 개선 방안을 제시하였다. 향후, 본 연구 결과는 환경 유해성을 고려한 화학물질관리법의 기본 취지에 부합하고, 산업계에도 현실적으로 적용될 수 있는 합리적인 기준마련에 기여할 수 있을 것으로 기대된다.

민감시설의 건물 특성에 따른 실내공기질 분석 (Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics)

  • 조경화;권순정;성민기;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in 'IAQ Control In Public-Use Facilities, etc. Act'. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

A Study on the Cremation Status of Public Cremation Facilities By Jurisdiction Area and Outside of the Jurisdiction Area Targeting Users of E-Haneul Funeral Information System in Jeollabuk-do

  • Choi, Jae-sil;Kim, Jeong-lae
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.187-197
    • /
    • 2021
  • We present following research summary and implications through the analysis of the research. First, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation increases to annual average of 5.5% of the rate, and it has a positive effect on increasing rate of the cremation. Therefore, a policy of expanding the supply of public cremation facilities should be pursued to improve cremation rate in the area of uninstalled public cremation facilities. Second, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation has increased to the annual average 3,623 people(56.9%) at jurisdiction area, while it has decreased to 949 people (28.3%) at the out of the jurisdiction area. The active efforts and building the funding expansion should be made to establish public cremation facilities of the central and local governments to improve convenience of the use of public cremation facilities. Third, since the before and after opening of public cremation facilities at Jeongeup City lead to great effect on demand of jurisdiction area and out of the jurisdiction area, the cremation demand should be reduced through the supply expansion of public cremation facilities and differentiation strategy to control cremation demand at the out of the jurisdiction area, focusing on metropolitan areas with high cremation demand, such as metropolitan areas or metropolitan cities.

의료기관 종사자의 병원감염관리에 대한 인지도와 수행도 (The Awareness and Performances of Medical staffs on the Infection Control in Health Care Facilities)

  • 서민정;박은태
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.131-138
    • /
    • 2017
  • 본 연구는 부산광역시 소재의 11개 병원에 근무하는 의료기관 종사자를 대상으로 병원감염관리 인지도와 수행도를 분석하였다. 그 결과, 병원 내 감염관리부서, 감염관리 지침서, 감염관리 교육의 유무에 관계없이 인지도, 수행도의 척도가 높게 나타났다. 특히, 감염교육을 받은 적이 있는 집단의 인지도, 수행도에서 통계적으로 유의한 결과를 보였다(p<0.001). 감염관리에 대한 수행을 실천하지 못하는 주된 원인은 업무과다와 시간부족으로 나타났으며, 99.7%의 응답자가 감염관리 교육이 필요하다고 답하여 사회 전반적으로 병원감염에 대한 경각심이 커진 것으로 판단된다. 전체적으로 인지도에 비해 수행도가 낮게 분석되었으며, 병원감염을 낮추기 위해서는 실현가능한 제도의 개선과 종사자 개인의 적극적인 수행이 필요할 것으로 사료된다.

광케이블을 이용한 발전소 계측제어시스템 (Power plant instrumentation and control system by using optical fiber cable)

  • 신건학;조홍근;오면택
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.79-84
    • /
    • 1990
  • Analog systems could not fully deal with instrumentation and control facilities in power plants since these facilities have become more and more complex on account of various needs for large power generation capacity highly cost effective operation to conserve energy and operation management to prevent pollution. Digitalizations of control device and augmentations of control informations increased the necessity of fiber optic data networks which have excellent noise immunity and high quality wide-band with information transfer capability. The goal of this study is to offer a fiber optic data-way system which has high reliabilities, high data transmission rates and small cable ducts with large transmission capacities for the instrumentation and control of power plants.

  • PDF