• Title/Summary/Keyword: Control device

Search Result 5,498, Processing Time 0.042 seconds

Assistant device development and effects for promotion of bag-valve-mask ventilation (백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과)

  • Kwon, Chan-Yang;Lee, In-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

Design and control of a flexible media handling device for inter-sheet spacing control (간격제어를 위한 유연매체 취급장치의 설계 및 제어)

  • Yim D.K.;Park S.W.;Yang H.S.;Park N.C.;Yoon J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1125-1130
    • /
    • 2005
  • This paper presents a method for inter-sheet spacing control in a flexible media handling device. In order to verify the performance of inter-sheet spacing control by experiment, system of section structure is introduced in the first place. In the introduced system, each section is driven by different servo motor for independent section freedom. And suitable inter-sheet spacing control algorithm that is more optimal than conventional inter-sheet spacing control algorithm is proposed. Finally experiments are performed to confirm the performance of inter-sheet spacing control. And two inter-sheet spacing control algorithms, conventional and proposed, are compared with each other.

  • PDF

A Study on Improvement of Submarine Torpedo Acoustic Counter Measure Launcher System Safety Device Performance (잠수함용 어뢰기만기 발사체계 안전장치 작동성능 향상에 관한 연구)

  • Chang, Ho-Seong;Seo, Dae-Su;Lee, Gyeong-Chan;Lee, Jong-Gwan;Jo, Byeong-Gi;Kim, Joong-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.411-424
    • /
    • 2018
  • Purpose: The purpose of this study is to improve submarine TACM launcher system safety device performance. Methods: In this study, EPLD(Electrically Programmable Logic Device) control and time sharing method to the safety device actuator motor and discrete signal processor in launch control panel were used to resolve unusual performance of safety system. Results: The result of this study are as follows; First, sporadic stopping of safety device actuator motor due to insufficient In-Rush current was resolved. Second, repeat of safety device condition as lock & release due to chattering for motor activating was resolved. Third, simultaneous release function for safety device actuator was available. Conclusion: The unusual performance of function for submarine TACM launcher system was overcame by applying EPLD control and time sharing method. The suggestions were proved by performance test in the pressure chamber. The results of this study enhanced survivability of ${\bigcirc}{\bigcirc}{\bigcirc}$ class submarine from enemy torpedo.

Plasma polymer passivated organic light emitting diodes

  • Cho, Dae-Yong;Kim, Min-Su;Jung, Dong-Geun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.893-896
    • /
    • 2003
  • Plasma polymerized para-xylene (PPpX) thin films deposited by plasma enhanced chemical vapor deposition (PECVD) were used to passivate the organic light emitting diodes (OLEDs). For OLEDs, indium tin oxide (ITO), N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-diphenyl-4,4'-diamine (TPD), tris(8-hydroxyquinoline) aluminum $(Alq_{3})$ and aluminum (Al) were used as the anode, the hole transport layer (HTL), the emitting layer (EML) and the cathode, respectively. The OLED device with the PPpX passivation film (passivated device) showed similar electrical and optical characteristics to those of the OLED device without the PPpX passivation film (control device), indicating that the PECVD process did not degrade the performance of the OLEDs notably. The lifetime of the passivated device was two times longer than that of the control device. Passivation of OLEDs with PPpX films also suppressed the growth of dark spots. The density and size of dark spots of the passivated device were much smaller than those of the control device.

  • PDF

Spectrum Reuse Schemes with Power Control for Device-to-Device Communication in LTE-Advanced Cellular Network

  • Chhorn, Sok;Yoon, Seok-Ho;Seo, Si-O;Kim, Seung-Yeon;Cho, Choong-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.12
    • /
    • pp.4819-4834
    • /
    • 2015
  • The spectral efficiency of cellular networks can be improved when proximate users engage in device-to-device (D2D) communications to communicate directly without going through a base station. However, D2D communications that are not properly designed may generate interference with existing cellular networks. In this paper, we study resource allocation and power control to minimize the probability of an outage and maximize the overall network throughput. We investigate three power control-based schemes: the Partial Co-channel based Overlap Resource Power Control (PC.OVER), Fractional Frequency Reuse based Overlap Resource Power Control (FFR.OVER) and Fractional Frequency Reuse based Adaptive Power Control (FFR.APC) and also compare their performance. In PC.OVER, a certain portion of the total bandwidth is dedicated to the D2D. The FFR.OVER and FFR.APC schemes combine the FFR techniques and the power control mechanism. In FFR, the entire frequency band is partitioned into two parts, including a central and edge sub-bands. Macrocell users (mUEs) transmit using uniform power in the inner and outer regions of the cell, and in all three schemes, the D2D receivers (D2DRs) transmit with low power when more than one D2DRs share a resource block (RB) with the macrocells. For PC.OVER and FFR.OVER, the power of the D2DRs is reduced to its minimum, and for the FFR.APC scheme, the transmission power of the D2DRs is iteratively adjusted to satisfy the signal to interference ratio (SIR) threshold. The three schemes exhibit a significant improvement in the overall system capacity as well as in the probability of a user outage when compared to a conventional scheme.

Device Control System based on Brain Wave Data (뇌파데이터 기반의 디바이스 제어 시스템)

  • Lee, So-Hyun;Lee, Ye-Jeong;Lee, Seok-cheol;Seo, Jeongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.813-815
    • /
    • 2016
  • This paper implements a device control system based on the brain wave data. Brain-Computer Interface (BCI) technology can pass directly to the system without going through the operation of the language or body. By controlling the device to detect brain waves in real time according to the change of status it helps to ease life for a variety of services, such as disabled people with limited mobility or students, people who need multi-tasking. In addition, it is possible to develop an application service such as the home device control system. A device control system implemented in the paper based on the data collected from the EEG Headset associated to control the power of the smart phone and audio. Control the power ON / OFF operation by the Attention, and support service functions to control the audio by the Meditation and Eye blink. It was confirmed that the device control using the brain wave data to be operated through a laboratory test successfully.

  • PDF

Development of Internet Web-Based UPS Remote Control System (인터넷 웹 기반 환경을 이용한 UPS 원격제어시스템 개발)

  • 김성환;최주엽;유권종;안현식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.253-259
    • /
    • 2003
  • This paper aims at developing remote control system to control and monitor distributed various devices such as UPS through internet. TCP/IP(Transmission Control Protocol/Internet Protocol) and UPS operated in a row are adopted for the network management protocol and the application device, respectively. For controlling and monitoring distributed devices in realtime, java-environment software is constructed. Also, HelloDevice, general-use interface controller between network device and applied device is proposed. Finally, serial communication such as RS-232C is used between controller and applied device.

Control and VR Navigation of a Gait Rehabilitation Robot with Upper and Lower Limbs Connections (상하지가 연동된 보행재활 로봇의 제어 및 VR 네비게이션)

  • Novandy, Bondhan;Yoon, Jung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.315-322
    • /
    • 2009
  • This paper explains a control and navigation algorithm of a 6-DOF gait rehabilitation robot, which can allow a patient to navigate in virtual reality (VR) by upper and lower limbs interactions. In gait rehabilitation robots, one of the important concerns is not only to follow the robot motions passively, but also to allow the patient to walk by his/her intention. Thus, this robot allows automatic walking velocity update by estimating interaction torques between the human and the upper limb device, and synchronizing the upper limb device to the lower limb device. In addition, the upper limb device acts as a user-friendly input device for navigating in virtual reality. By pushing the switches located at the right and left handles of the upper limb device, a patient is able to do turning motions during navigation in virtual reality. Through experimental results of a healthy subject, we showed that rehabilitation training can be more effectively combined to virtual environments with upper and lower limb connections. The suggested navigation scheme for gait rehabilitation robot will allow various and effective rehabilitation training modes.

Obstacle Information Transfer and Control Method using Haptic Device consist of Vibration Motors (진동모터로 구성된 햅틱 디바이스를 이용한 장애물 정보 전달 및 제어 방법)

  • Lee, Dong-Hyuk;Noh, Kyung-Wook;Kang, Sun Kyun;Han, Jong Ho;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.10
    • /
    • pp.1036-1043
    • /
    • 2014
  • In this paper, a new haptic device is proposed for the teleoperation, which can recognize the invisible environment of a mobile robot. With this new device, it is possible for the user to identify the location of an obstacle and to avoid it. The haptic device has been attached on the top of a joystick so that the user can remotely control the mobile robot to avoid the obstacles which are recognized by the ultrasonic sensors. Also, the invisible environment is recognized more accurately overlapping the data from the ultrasonic sensors. There are five vibration motors in the haptic device to indicate the direction of the obstacle. So the direction of the obstacle can be recognized by the vibration at the finger on each vibration motor. For various situations and surrounding environments, experiments are performed using fuzzy controller and overlapping ultrasonic sensors. The results demonstrate the effectiveness of the proposed haptic joystick.

WiFi Wireless Network based Control System (WiFi 무선 네트워크 기반의 제어 시스템)

  • Jeong, Eui-Hoon;Lim, Jung-Gwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.575-577
    • /
    • 2013
  • Recently most of the hand-held smart devices have WiFi communication facility. This makes WiFi AP(access point) popular and cheaper than before. These circumstance launches some services with AP providing location based services and device control services. In this paper, we propose a AP based control system. The control system consists of AP's, AP controller and Android application program. The AP can collect MAC address information of the associated smart devices and control connected devices. The AP controller maintains DB for smart device position information and device control information. Finally Android application program provides users location based service and device control service.

  • PDF