• 제목/요약/키워드: Control cooling

검색결과 1,412건 처리시간 0.022초

빙축열 냉방 시스템의 동적 시뮬레이션 (Dynamic simulation of the ice storage cooling system)

  • 한도영;이준호
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.815-823
    • /
    • 1999
  • A dynamic simulation program may be used for the development of effective control algorithms for the ice storage cooling system. Simplified effective dynamic models for an ice-on-coil type storage tank, a screw chiller, a water-to-air heat exchanger, three way valves, pipes, pumps, temperature sensors, and controllers were developed. And a dynamic simulation program for the ice storage cooling system was developed by using these dynamic models. Control algorithms for the full storage system were also selected and analyzed in order to show the effectiveness of these models. From the simulation results, it may be concluded that the simulation program developed in this study can be effectively used for the development of improved control algorithms for the ice storage cooling system.

  • PDF

전자식 엔진냉각제어 시스템을 위한 팬 클러치 특성 분석 (Analysis of fan clutch characteristics for electronic engine cooling control system)

  • 류혜연;김현희;정성민;고영호;이경창
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.241-246
    • /
    • 2018
  • The engine cooling system is a device that keeps the temperature of the engine room at a proper level by driving the cooling fan when the engine room temperature that occurs during driving is above a certain temperature. Recently, the vehicle cooling system has been changed to electronic system. Therefore, in this paper, we will analyze the clutch operation characteristics for designing a superior electronic fan clutch. For this purpose, an electronic fan clutch was designed and a test bed for performance evaluation was constructed and analyzed.

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • 제4권2호
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

지하 교각 기초의 온도균열 제어를 위한 수화열 해석 연구 (A Study of the Thermal Analysis for the Crack Control of Underground Pier Footing)

  • 박원태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.91-101
    • /
    • 2006
  • 최근들어 매스콘크리트 구조물의 시공이 증가 추세에 있다. 이러한 매스콘크리트는 수화열상승으로 온도균열이 발생할 수 있다. 온도균열을 방지하기 위하여 일반적으로 프리 쿨링, 파이프 쿨링 및 타설높이를 제한하는 방법이 사용된다. 본 연구에서는 교각 기초의 온도균열을 방지하기 위하여 열응력 검토를 실시하였으며, 이때 기초는 $12m{\times}14m$의 면적과 3m 높이를 가지는 것을 모델로 하였다. 타설 높이를 제한하는 방법과 파이프 쿨링에 의한 해석결과를 비교 검토 하였다. 온도응력를 해석한 결과 지반위에 타설한 기초매트는 타설높이를 제한하는 방법과 파이프쿨링 방법에 의해 균열을 제어할 수 있다.

온실 포그 냉방 제어시스템 개발 및 냉방효과 (Development of Fog Cooling Control System and Cooling Effect in Greenhouse)

  • 박석호;문종필;김진구;김승희
    • 생물환경조절학회지
    • /
    • 제29권3호
    • /
    • pp.265-276
    • /
    • 2020
  • 본 연구는 여름철 고온기에 작물을 정상적으로 재배할 수 있는 환경을 조성하여 농산 가격이 가장 높은 여름철에 수확량을 높이고 재배기간을 연장시켜 농가소득을 올릴 수 있는 방안을 제시하고자 수행하였다. 바닥면적 504㎡의 연동온실의 최대 냉방부하는 462,609W로 나타났으며, 고온기에 온실을 차광하지 않고도 32℃ 이하로 유지하기 위해서는 시간당 472L의 물을 포그 분무해야 하는 것으로 나타났다. 포그 냉방 시스템은 포그 장치, 유동팬, 차광장치로 구성하고, 이들 장치를 효과적으로 제어할 수 있는 포그 냉방 자동제어장치를 개발하였다. 포그 냉방시스템의 냉방 성능은 온실 외기온 보다 내부온도를 6℃ 낮출 수 있는 것으로 나타났다. 포그 온실의 내부 상대습도는 주간에는 40~80%로 대조 온실의 20~60% 보다 약 20% 높게 나타나 오이의 생육에 기여하는 것으로 나타났다. 오이의 생육상태는 포그 온실에서 재배한 오이가 대조 온실에 비해 초장, 엽장, 엽폭, 엽수, 엽록소 값이 전체적으로 높게 나타났다. 포그 온실의 오이 수확량은 대조 온실에 비해 단동 온실에서는 1.8배, 연동 온실에서는 2배 높게 나타났다.

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

Optimized Digital Proportional Integral Derivative Controller for Heating and Cooling Injection Molding System

  • Jeong, Byeong-Ho;Kim, Nam-Hoon;Lee, Kang-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1383-1388
    • /
    • 2015
  • Proportional integral derivative (PID) control is one of the conventional control strategies. Industrial PID control has many options, tools, and parameters for dealing with the wide spectrum of difficulties and opportunities in manufacturing plants. It has a simple control structure that is easy to understand and relatively easy to tune. Injection mold is warming up to the idea of cycling the tool surface temperature during the molding cycle rather than keeping it constant. This “heating and cooling” process has rapidly gained popularity abroad. However, it has discovered that raising the mold wall temperature above the resin’s glass-transition or crystalline melting temperature during the filling stage is followed by rapid cooling and improved product performance in applications from automotive to packaging to optics. In previous studies, optimization methods were mainly selected on the basis of the subjective experience. Appropriate techniques are necessary to optimize the cooling channels for the injection mold. In this study, a digital signal processor (DSP)-based PID control system is applied to injection molding machines. The main aim of this study is to optimize the control of the proposed structure, including a digital PID control method with a DSP chip in the injection molding machine.

중앙 냉방시스템에 대한 외기보상제어의 절약 성능에 관한 실험적 연구 (Experimental Study on Energy Saving Performance of Outdoor Temperature Reset Control Strategy for Central Cooling System)

  • 김동철;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.30-36
    • /
    • 2011
  • In this study, energy saving performance of outdoor temperature reset control strategy for central cooling system is researched by experiments. Outdoor temperature reset control is the control method to change indoor air set temperature according to outdoor air temperature change. The range of indoor air set temperature is represented by the comfort temperature range of indoor air temperature offered from ASHRAE and indoor air set temperature is programmed between $22^{\circ}C$ and $27^{\circ}C$ by outdoor air temperature $20^{\circ}C{\sim}32^{\circ}C$ in summer. As a result of applying outdoor temperature reset control to central cooling system, the suggested control method shows better performances of energy savings than the conventional method which indoor temperature maintains constantly.

Improvement of Cooling Technology through Atmosphere Gas Management

  • Renard, Michel;Dosogne, Edgar;Crutzen, Jean-Pierre;Raick, Jean-Marc;Ma, Jia Ji;Lv, Jun;Ma, Bing Zhi
    • Corrosion Science and Technology
    • /
    • 제8권6호
    • /
    • pp.217-222
    • /
    • 2009
  • The production of advanced high strength steels requires the improvement of cooling technology. The use of high cooling rates allows relatively low levels of expensive alloying additions to ensure sufficient hardenability. In classical annealing and hot-dip galvanizing lines a mixing station is used to provide atmosphere gas containing 3-5% hydrogen and 97-95% nitrogen in the various sections of the furnace, including the rapid cooling section. Heat exchange enhancement in this cooling section can be insured by the increased hydrogen concentration. Drever International developed a patented improvement of cooling technology based on the following features: pure hydrogen gas is injected only in the rapid cooling section whereas the different sections of the furnace are supplied with pure nitrogen gas; the control of flows through atmosphere gas management allows to get high hydrogen concentration in cooling section and low hydrogen content in the other furnace zones. This cooling technology development insures higher cooling rates without additional expensive hydrogen gas consumption and without the use of complex sealing equipments between zones. In addition reduction in electrical energy consumption is obtained. This atmosphere control development can be combined with geometrical design improvements in order to get optimised cooling technology providing high cooling rates as well as reduced strip vibration amplitudes. Extensive validation of theoretical research has been conducted on industrial lines. New lines as well as existing lines, with limited modifications, can be equipped with this new development. Up to now this technology has successfully been implemented on 6 existing and 7 new lines in Europe and Asia.

태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF