• Title/Summary/Keyword: Control circuit

Search Result 3,859, Processing Time 0.028 seconds

Electrical Properties for Enhanced Band Offset and Tunneling with a-SiOx:H/a-si Structure (a-SiOx:H/c-Si 구조를 통한 향상된 밴드 오프셋과 터널링에 대한 전기적 특성 고찰)

  • Kim, Hongrae;Pham, Duy phong;Oh, Donghyun;Park, Somin;Rabelo, Matheus;Kim, Youngkuk;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.4
    • /
    • pp.251-255
    • /
    • 2021
  • a-Si is commonly considered as a primary candidate for the formation of passivation layer in heterojunction (HIT) solar cells. However, there are some problems when using this material such as significant losses due to recombination and parasitic absorption. To reduce these problems, a wide bandgap material is needed. A wide bandgap has a positive influence on effective transmittance, reduction of the parasitic absorption, and prevention of unnecessary epitaxial growth. In this paper, the adoption of a-SiOx:H as the intrinsic layer was discussed. To increase lifetime and conductivity, oxygen concentration control is crucial because it is correlated with the thickness, bonding defect, interface density (Dit), and band offset. A thick oxygen-rich layer causes the lifetime and the implied open-circuit voltage to drop. Furthermore the thicker the layer gets, the more free hydrogen atoms are etched in thin films, which worsens the passivation quality and the efficiency of solar cells. Previous studies revealed that the lifetime and the implied voltage decreased when the a-SiOx thickness went beyond around 9 nm. In addition to this, oxygen acted as a defect in the intrinsic layer. The Dit increased up to an oxygen rate on the order of 8%. Beyond 8%, the Dit was constant. By controlling the oxygen concentration properly and achieving a thin layer, high-efficiency HIT solar cells can be fabricated.

An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error (전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구)

  • Lee, Byung Wook;Oh, Yong Taek;Jang, Hansol;Choi, Seong-Kyeong;Jo, Hyo Rim;Sung, Won-Suk;Kim, Eun-Jung
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

Implementation of IoT-Based Irrigation Valve for Rice Cultivation (벼 재배용 사물인터넷 기반 물꼬 구현)

  • Byeonghan Lee;Deok-Gyeong Seong;Young Min Jin;Yeon-Hyeon Hwang;Young-Gwang Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.6
    • /
    • pp.93-98
    • /
    • 2023
  • In paddy rice farming, water management is a critical task. To suppress weed emergence during the early stages of growth, fields are deeply flooded, and after transplantation, the water level is reduced to promote rooting and stimulate stem generation. Later, water is drained to prevent the production of sterile tillers. The adequacy of water supply is influenced by various factors such as field location, irrigation channels, soil conditions, and weather, requiring farmers to frequently check water levels and control the ingress and egress of water. This effort increases if the fields are scattered in remote locations. Automated irrigation systems have been considered to reduce labor and improve productivity. However, the net income from rice production in 2022 was about KRW 320,000/10a on average, making it financially unfeasible to implement high-cost devices or construct new infrastructure. This study focused on developing an IoT-Based irrigation valve that can be easily integrated into existing agricultural infrastructure without additional construction. The research was carried out in three main areas: Firstly, an irrigation valve was designed for quick and easy installation on existing agricultural pipes. Secondly, a power circuit was developed to connect a low-power Cat M1 communication modem with an Arduino Nano board for remote operation. Thirdly, a cloud-based platform was used to set up a server and database environment and create a web interface that users can easily access.

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Retrograde Autologous Priming: Is It Really Effective in Reducing Red Blood Cell Transfusions during Extracorporeal Circulation? (역행성 자가혈액 충전법: 체외순환 중 동종적혈구 수혈량을 줄일 수 있는가?)

  • Lim, Cheong;Son, Kuk-Hui;Park, Kay-Hyun;Jheon, Sang-Hoon;Sung, Sook-Whan
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.473-479
    • /
    • 2009
  • Background: Retrograde autologous priming (RAP) is known to be useful in decreasing the need of transfusions in cardiac surgery because it prevents excessive hemodilution due to the crystalloid priming of cardiopulmonary bypass circuit. However, there are also negative side effects in terms of blood conservation. We analyzed the intraoperative blood-conserving effect of RAP and also investigated the efficacy of autotransfusion and ultrafiltration as a supplemental method for RAP. Material and Method: From January 2005 to December 2007, 117 patients who underwent isolated coronary artery bypass operations using cardiopulmonary bypass (CPB) were enrolled. Mean age was 63.9$\pm$9.1 years (range 36$\sim$83 years) and 34 patients were female. There were 62 patients in the RAP group and 55 patients in he control group. Intraoperative autotransfusion was performed via the arterial line. RAP was done just before initiating CPB using retrograde drainage of the crystalloid priming solution. Both conventional (CUF) and modified (MUF) ultrafiltrations were done during and after CPB, respectively. The transfusion threshold was less than 20% in hematocrit. Result: Autotransfusions were done in 79 patients (67.5%) and the average amount was 142.5$\pm$65.4 mL (range 30$\sim$320 mL). Homologous red blood cell (RBC) transfusion was done in 47 patients (40.2%) and mean amount of transfused RBC was 404.3$\pm$222.6 mL. Risk factors for transfusions were body surface area (OR 0.01, 95% CI 0.00 $\sim$ 0.63, p=0.030) and cardiopulmonary bypass time (OR 1.04, 95% CI 1.01 $\sim$ 1.08, p=0.019). RAP was not effective in terms of the rate of transfusion (34.5% vs 45.2%, p=0.24). However, the amount of transfused RBC was significantly decreased (526.3$\pm$242.3ml vs 321.4$\pm$166.3 mL, p=0.001). Autotransfusion and ultrafiltration revealed additive and cumulative effects decreasing transfusion amount (one; 600.0$\pm$231.0 mL, two; 533.3$\pm$264.6 mL, three; 346.7$\pm$176.7 mL, four; 300.0$\pm$146.1 mL, p=0.002). Conclusion: Even though RAP did not appear to be effective in terms of the number of patients receiving intraoperative RBC transfusions, it could conserve blood in terms of the amount transfused and with the additive effects of autotransfusion and ultrafiltration. If we want to maximize the blood conserving effect of RAP, more aggressive control will be necessary - such as high threshold of transfusion trigger or strict regulation of crystalloid infusion, and so forth.

26GHz 40nm CMOS Wideband Variable Gain Amplifier Design for Automotive Radar (차량용 레이더를 위한 26GHz 40nm CMOS 광대역 가변 이득 증폭기 설계)

  • Choi, Han-Woong;Choi, Sun-Kyu;Lee, Eun-Gyu;Lee, Jae-Eun;Lim, Jeong-Taek;Lee, Kyeong-Kyeok;Song, Jae-Hyeok;Kim, Sang-Hyo;Kim, Choul-Young
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.408-412
    • /
    • 2018
  • In this paper, a 26GHz variable gain amplifier fabricated using a 40nm CMOS process is studied. In the case of an automobile radar using 79 GHz, it is advantageous in designing and driving to drive down to a low frequency band or to use a low frequency band before up conversion rather than designing and matching the entire circuit to 79 GHz in terms of frequency characteristics. In the case of a Phased Array System that uses time delay through TTD (True Time Delay) in practice, down conversion to a lower frequency is advantageous in realizing a real time delay and reducing errors. For a VGA (Variable Gain Amplifier) operating in the 26GHz frequency band that is 1/3 of the frequency of 79GHz, VDD : 1V, Bias 0.95V, S11 is designed to be <-9.8dB (Mea. High gain mode) and S22 < (Mea. high gain mode), Gain: 2.69dB (Mea. high gain mode), and P1dB: -15 dBm (Mea. high gain mode). In low gain mode, S11 is <-3.3dB (Mea. Low gain mode), S22 <-8.6dB (Mea. low gain mode), Gain: 0dB (Mea. low gain mode), P1dB: -21dBm (Mea. Low gain mode).

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Analysis of the Effect of the Etching Process and Ion Injection Process in the Unit Process for the Development of High Voltage Power Semiconductor Devices (고전압 전력반도체 소자 개발을 위한 단위공정에서 식각공정과 이온주입공정의 영향 분석)

  • Gyu Cheol Choi;KyungBeom Kim;Bonghwan Kim;Jong Min Kim;SangMok Chang
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.255-261
    • /
    • 2023
  • Power semiconductors are semiconductors used for power conversion, transformation, distribution, and control. Recently, the global demand for high-voltage power semiconductors is increasing across various industrial fields, and optimization research on high-voltage IGBT components is urgently needed in these industries. For high-voltage IGBT development, setting the resistance value of the wafer and optimizing key unit processes are major variables in the electrical characteristics of the finished chip. Furthermore, the securing process and optimization of the technology to support high breakdown voltage is also important. Etching is a process of transferring the pattern of the mask circuit in the photolithography process to the wafer and removing unnecessary parts at the bottom of the photoresist film. Ion implantation is a process of injecting impurities along with thermal diffusion technology into the wafer substrate during the semiconductor manufacturing process. This process helps achieve a certain conductivity. In this study, dry etching and wet etching were controlled during field ring etching, which is an important process for forming a ring structure that supports the 3.3 kV breakdown voltage of IGBT, in order to analyze four conditions and form a stable body junction depth to secure the breakdown voltage. The field ring ion implantation process was optimized based on the TEG design by dividing it into four conditions. The wet etching 1-step method was advantageous in terms of process and work efficiency, and the ring pattern ion implantation conditions showed a doping concentration of 9.0E13 and an energy of 120 keV. The p-ion implantation conditions were optimized at a doping concentration of 6.5E13 and an energy of 80 keV, and the p+ ion implantation conditions were optimized at a doping concentration of 3.0E15 and an energy of 160 keV.