• Title/Summary/Keyword: Control and response characteristics

Search Result 1,484, Processing Time 0.028 seconds

Optimal Design and Development of Electromagnetic Linear Actuator for Mass Flow Controller

  • Chung, Myung-Jin;Gweon, Dae-Gab
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.40-47
    • /
    • 2003
  • In this paper, we constructed the analytic model of control valve as a function of electric and geometric parameters, and analyzed the influence of the design parameters on the dynamic characteristics. For improving the dynamic characteristics, optimal design is conducted by applying sequential quadratic programming method to the analytic model. This optimal design aims to minimize the response time and maximize force efficiency. By this procedure, control valve can be designed to have fast response in motion.

Analysis of Dynamic Characteristics on Condenser for the Control of Air Conditioning Systems (공조기 제어를 위한 응축기의 동특성 해석)

  • Kim, J.D.;Yoon, J.I.;Higuchi, K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.386-396
    • /
    • 1996
  • The dynamic characteristics of a condenser are numerically studied for the control of air-conditioning systems. The important factors, such as the refrigerant flow rate and refrigerant temperature, air velocity and air temperature at the condenser inlet, are incorporated into the analysis. This study was focused on the analysis of dynamic responses by transfer function method in the condenser. Block diagrams were made through analytic transfer function, and dynamic responses are evaluated on Bode diagrams in the frequency response. These results may be used for determining an optimum design parameters in an actual component and total systems. Also, the mathematical models, frequency response and steady state response may be used to increase understanding, to obtain useful information for its commercialization, to evaluate the hardware and the optimum design parameters, the design control system and to determine the best controller setting for the refrigeration and air conditioning systems.

  • PDF

Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve (공압밸브의 동적응답 특성측정 자동화 시스템 개발)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

Experimental Analysis of the Static and Dynamic Characteristics for a Pilot Proportional Pressure Control Valve (파일럿 비례압력제어밸브의 정특성 및 동특성에 관한 실험적 분석)

  • Jeong, H.S.;Nam, J.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.4
    • /
    • pp.9-16
    • /
    • 2011
  • Because of the increasing demand on the high precision and high response of a machinery, proportional control valves are widely adopted at various application fields. This paper studies on the static and dynamic characteristics of a pilot proportional pressure control valve. An experimental apparatus including hydraulic pump, variable speed inverter, pressure and flow sensors and data aquisition system was set up. And various experiments such as P-Q-V curves, step responses due to input voltage and flow rate, hysteresis, frequency response of the proportional valve was carried out and the results are discussed.

A Study on Dynamic Characteristics Improvement of Fast Response Proportional Flow Control Valve (고응답 비래 유량제어 밸브의 동특성 향상에 관한 연구)

  • 김고도;김원수;이현철;윤소남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1053-1057
    • /
    • 1996
  • The purpose of this study is to bring out the optimal design factors which effect on dynamic characteristics in the design of proportional flow control valve with fast response characteristics, and to verify the validity of the design factors In this study, force feedback type flow control valve with nozzle-flapper is studied. And, the influences which fixed orifice, nozzle diameter, and maximum displacement between nozzle and flapper effect on dynamic characteristics are analyzed. We have done simulations using the optimal design factors and simulink(Matlab) as a simulation tool, and verified the validity of our simulations by means of comparison our simulation results with an experimental results of another similar valve.

  • PDF

Seismic response control of buildings using shape memory alloys as smart material: State-of-the-Art review

  • Eswar, Moka;Chourasia, Ajay;Gopalakrishnan, N.
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.207-219
    • /
    • 2022
  • Seismic response control has always been a grave concern with the damage and collapse of many buildings during the past earthquakes. While there are several existing techniques like base isolation, viscous damper, moment-resisting beam-column connections, tuned mass damper, etc., many of these are succumbing to either of large displacement, near-fault, and long-period earthquakes. Keeping this viewpoint, extensive research on the application of smart materials for seismic response control of buildings was attempted during the last decade. Shape Memory Alloy (SMA) with its unique properties of superelasticity and shape memory effect is one of the smart materials used for seismic control of buildings. In this paper, an exhaustive review has been compiled on the seismic control applications of SMA in buildings. Unique properties of SMA are discussed in detail and different phases of SMA along with crystal characteristics are illustrated. Consequently, various seismic control applications of SMA are discussed in terms of performance and compared with prevalent base isolators, bracings, beam-column connections, and tuned mass damper systems.

Dynamic response analysis of closed loop control system for intelligent truss structures based on probability

  • Gao, W.;Chen, J.J.;Ma, H.B.;Ma, X.S.;Cui, M.T.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.2
    • /
    • pp.239-248
    • /
    • 2003
  • The dynamic response analysis of closed loop control system based on probability for the intelligent truss structures with random parameters is presented. The expressions of numerical characteristics of structural dynamic response of closed loop control system are derived by means of the mode superposition method, in which the randomness of physical parameters of structural materials, geometric dimensions of active bars and passive bars, applied loads and control forces are considered simultaneously. The influences of the randomness of them on structural dynamic response are inspected by several engineering examples and some significant conclusions are obtained.

Static and Dynamic Characteristics of Electro - hydraulic Proportional Throttle Control Valve (전자 유압식 비례 교축 제어 밸브의 특성)

  • 오인호;이일영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.87-99
    • /
    • 1993
  • Nowadays, the cartridge valve can be controlled proportionally in remote place by adopting proportional solenoid and it becomes widely used as control component in hydraulic systems. Especially, multi stage proportional valve is attractive because it consumes less input power though its characteristics might slightly be defected. But, the system parameter should be carefully chosen to obtain optimistic characteristics. This study concerning three stage proportional throttle control valve is purposed to examine the influences of paameters to the dynamic characteristics. The typical transient and frequency responses of proportional throttle control valve were inspected through the experiments and compared to those derived from the theoritical analyses. And it was confirmed that the analyses are appropriate. Then the influences of various system parameters to the dynamic characteristics were examined by means of simulations. For the analyses, the basic equations derived from lumped model were linearized and the linearized equations were transformed to the transfer functions between inputs and outputs. Then the transient responses and frequency responses were obtained from transfer functions. 1. It is appropriate to estimate the dynamic characteristics of valve which has relatively sophisticated structure by means of system analyses using linearized equations. 2. Though the valve has two pilot stages, fairly good characteristics can be obtained by carefully choosing system parameters. 3. Main valve very quickly follows the movement of second pilot valve when the parameters of main valve(the oil supply passage and discharge passage fpr second pilot valve) are appropriately chosen.

  • PDF

Response Calibration for Bridges based on Statistical Quality Control Chart (통계적 품질 관리도에 기초한 교량의 응답 보정)

  • Hwang, Jin Ha;An, Seoung Su;Kim, Ju Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • This paper presents the response calibration method based on quality control range, which is established from the concept and method of statistical quality control for natural frequency ratio and response ratio. To this end, statistical analysis including descriptive statistics analysis, normality test, ANOVA were performed for response characteristics obtained from loading tests and structural analysis for more than hundred and thirty well-conditioned bridges. Suggested method is based on real structural integrity evaluation case studies and statistical quality control approach, in this respect it is expected to provide scientific criteria and systematic procedure for response calibration and load carrying capacity assessment.

Dynamic Characteristic Analysis of Air-Conditioning System Using Solar Energy (태양열 이용 공조시스템의 동특성 해석)

  • Kim, J.D.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.75-83
    • /
    • 1999
  • The optimum drive control method have to be developed to exhibit the use object contributed trust, accuracy, amenity and energy save of product. To develop the optimum drive control method is, first, grasped the static characteristics for the entire system combined each element which consists the machine and performed the dynamic characteristics explanation based on the satisfied result which acquires at the static characteristics explanation. According to this explanation, the response of the system shows same characteristics tendency and the increasing same quantify comparing to response change of each element. So the dynamic response of the entire system shows different. Therefore this study performs the static and the dynamic characteristic explanation of entire system and each element for using air-conditioning system of solar energy based on the performed result from now on, so for application of this result.

  • PDF