• 제목/요약/키워드: Control & Operation Technology

검색결과 2,399건 처리시간 0.031초

동적 구문처리기 소프트웨어 적용을 통한 대화력전 수행체계 연동의 유연성 향상 방안 (Improving Flexibility of External Data Exchange in Count-fire Operation System by Adapting Dynamic Parser Software)

  • 홍원의
    • 한국군사과학기술학회지
    • /
    • 제11권1호
    • /
    • pp.51-56
    • /
    • 2008
  • The counter-fire operation system performs its mission exchanging information with other related systems such as command & control systems and military information systems. In the process of exchanging information, the counter-fire operation system uses a type of data message which contains exchange data information in the format of KMTF. The requirement of data exchange of count-fire operation will continue to evolve. But the EDX(External Data eXchange) configuration item of the current counter-fire operation system can not effectively cope with the variation of data exchange requirements due to its fixed software structure. In the paper, a solution for improving flexibility of external data exchange in counter-fire operation system is proposed.

비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어 (Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter)

  • 이해춘;박태열;김기택
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

Development of PLC networking for communication with mobile phones

  • Tasapark, Jirawan;Tangsrirat, Worapong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1221-1224
    • /
    • 2004
  • This paper presents the programmable logic controller (PLC) networking development for communication with the mobile phone. The proposed technique is suitable for remote sensing control systems, which can display the operation status and monitoring fault diagnosis of a system. The system operation is based on the use of personal computer (PC) to logically analyze data from PLC, and existing internet protocol for sending information messages to mobile phones.

  • PDF

A Study on a Human-Oriented Compensator for the Human-Machine System

  • Ohtsuka, Hirofumi;Shibasato, Koki;Uemura, Hirofumi;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.657-662
    • /
    • 2003
  • A mechanical system controlled by human operator, such as master-slave system, includes human dynamics in the whole system and such a system is called a human-machine system. In the system, operator's skill is required considerably in order to realize a meaningful operation. In this paper, a new concept and design strategy of compensator that improves the operativity of human-machine system are proposed. The compensator is called "collaborater "that is named after "collaborator" who works together with people. We mean not to design the automatic controller but the compensator that works together with a machine so that human feels the fulfillment in the operation. Our aim is to realize cooperation of people and a machine on a higher level.

  • PDF

독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구 (A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid)

  • 최정식;오승열;차대석;정동화
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.

원격 로봇 비주얼 가이던스를 위한 가상벽 가시화 방법론 비교 (Methodological Comparison of Visualization for Tele-operated Robot Visual Guidance)

  • 김동엽;신동인;황정훈;김영욱
    • 제어로봇시스템학회논문지
    • /
    • 제22권11호
    • /
    • pp.877-882
    • /
    • 2016
  • Disaster robots have accepted tele-operation in order to share the intelligence of human operators and robot systems. Virtual wall is one of the tele-operation technology to support recognition of human operator. If the virtual wall can block the robot from dangers, the operator will feel comfortable and can concentrate on fundamental missions. In this paper, we proposes and compares three methods for virtual wall visualization in tele-operation using 3D reconstruction. First is a virtual wall visualized only with edges. A wall filled with transparent color is the second method. Finally, third method is a texture-mapped virtual wall. In the experiments, we discuss their merits and demerits in view of robot tele-operation.

콘테이너 크레인의 자동화에 관한 기초연구 (Fundamental Study for Automation of Container Cranes)

  • 신민생;이동철;김상봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권2호
    • /
    • pp.83-90
    • /
    • 1994
  • The container crane is still operated by skillfull human operators. So an automatic crane operation system is strongly required. In this paper, the digital control method is applied to position an anti-swing control for container crane. Two methods of digital optimal regulator control and digital redesign control are used for experiment. From these experimental results, it is respected that both methods can be applied effectively to an actual container crane operation.

  • PDF

운항선 중심의 선박 경제운항 관리의 기술적 분석 (Technical Analysis on Existing Ship's Economical Operation)

  • 강남선;김용대;윤현규;변상수
    • 한국항행학회논문지
    • /
    • 제20권6호
    • /
    • pp.519-527
    • /
    • 2016
  • 본 논문에서는 해운선사의 운영비용 관리를 위해서 현존선의 항차 단위의 선박 경제운항 기술을 위한 개념 연구를 수행하였다. 해운산업 현황과 경제운항 기술개발 현황, 기술 요구사항 및 선박 운영에 필요한 비용 요소를 분석하여 경제운항 관리요소를 도출하였다. 개별 항차를 기준으로 현존선의 경제운항은 연료비와 항만에서 사용되는 비용을 최소화 하는 것이며, 이를 위해서 저속운항, 정속운항, 배수량 관리, 최적 트림, 최적 항로 선정, 터미널 생산성 관리, 선박 에너지 절감 활동을 관리한다. 최적항로, 터미널 생산성 관리는 절감된 시간으로, 저속운항, 정속운항, 최적트림, 선박 에너지 절감은 권고사항 만족 여부를 관리한다.

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

지선구간의 선로전환기 및 건널목 무선제어 운영절차 연구 (A Study on the Radio-Based Operation Procedures of Switch and Crossing at Branch Line)

  • 김영훈;최원석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1269-1274
    • /
    • 2011
  • To cut down the maintenance expenses at branch lines, the foreign developed countries have developed the low-cost signalling on low-density lines. These examples are FFB(FunkFahrBetrieb) Radio based train operation by German railways(Deutsche Bahn AG), ERTMS REGIONAL by Europe and LOCOPROL system using a GPS. Also, Korea is developing Information and Communication Technology based low-cost signalling on low-density lines. The characteristics of this system are directly controled switch and crossing by driver. For the purpose of this paper, we reviewed the business process for switch and crossing control. Specially, we compared and analysed both methods whether the driver takes control over the operation procedures of switch or the control message is carried by the command of the controller. And by utilizing the instrument of UML, I planned the switch according to the control authority and the operation procedures needed for the control of crossing.

  • PDF