• 제목/요약/키워드: Contrast phase

검색결과 833건 처리시간 0.054초

Phase-based virtual image encryption and decryption system using Joint Transform Correlator

  • Seo, Dong-Hoan;Cho, Kyu-Bo;Park, Se-Joon;Cho, Woong-Ho;Noh, Duck-Soo;Kim, Soo-Joong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.450-453
    • /
    • 2002
  • In this paper a Phase-based virtual image encryption and decryption techniques based on a joint transform correlator (JTC) are proposed. In this method, an encrypted image is obtained by multiplying a phase-encoded virtual image that contains no information from the decrypted image with a random phase. Even if this encryption process converts a virtual image into a white-noise-like image, the unauthorized users can permit a counterfeiting of the encrypted image by analyzing the random phase mask using some phase-contrast technique. However, they cannot reconstruct the required image because the virtual image protects the original image from counterfeiting and unauthorized access. The proposed encryption technique does not suffer from strong auto-correlation terms appearing in the output plane. In addition, the reconstructed data can be directly transmitted to a digital system for real-time processing. Based on computer simulations, the proposed encryption technique and decoding system were demonstrated as adequate for optical security applications.

  • PDF

상변태를 고려한 탄소강 용접부의 잔류응력 해석에 관한 연구 (A Study on the Analysis of Residual Stress in Weldment by Considering the Phase Transformation of Carbon Steel)

  • 조시훈;김재웅
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.390-398
    • /
    • 2001
  • Welding process generates distortion and residual stress in the weldment due to rapid heating and cooling. Welding distortion and residual stress in the welded structure result in many troubles such as dimensional inaccuracies in assembling and safety problem during service. The accurate prediction of welding residual stress is thus very important to improve the quality of weldment and find the way to reduce itself. This paper suggests new analysis method to predict welding residual stress by considering solid phase transformation during welding process. Using the method, analysis is performed for medium and low carbon steel. The analysis result for medium carbon steel reveals that case considering phase transformation has compressive residual stress in contrast with the case neglecting phase transformation because of martensite formation. However, for the case of low carbon steel, residual stress shows little difference between the case considering phase transformation and the other case, because it has small transformation strain and recovers rapidly stress after phase transformation.

유동모형을 이용한 저속유동의 자기공명영상 (MR Imaging of Slow-flow Using a Flow Phantom)

  • Dae-Cheol Cheong;Kyung-Jae Jung;Young-Hwan Lee;Nak-Kwan Sung;Duck-Soo Chung;Ok-Dong Kim;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권2호
    • /
    • pp.116-122
    • /
    • 2001
  • 목적 : 고식적 스핀에코, 위상 대조 경사에코, 고속 GRASS, 중T-2강조 고속스핀에코 연쇄를 각각 유동모형에 적용시켜, 저속유동에 대한 자기공명영상의 민감도를 찾아내고자 한다. 대상 및 방법 뇌실-복강 단락 도관과 GE 모형으로 이루어진 유동모형으로 싸이폰 효과에 의한 지속적인 가변 유속의 흐름을 내보내고, 각각의 유속에 위의 네 가지 자기공명영상연쇄를 적용시켰다. 0.08 ml/min 에서 1.7 ml/min 범위의 유량의 흐르는 액체와 정지된 액체에서 획득된 자기공명영상의 신호강도를 비교한 결과를 요약하면 다음과 같다. 결과 0.17 ml/min 이상의 느린 흐름에서는 고식적 스핀에코영상이 가장 우수한 정지-유동 액체사이의 겉보기대조를 보이나, 그 이하의 매우 느린 흐름에서는 GRASS 영상이 더 높은 민감도를 보였다. 결론 : 4가지 자기공명펄스연쇄는 0.08 ml/min에서 1.7 ml/min 범위의 유량의 흐름에서 서로 다른 민감도를 보였다. 이 결과는 임상적으로, 단락수술후의 뇌척수액의 흐름이나 혈관내의 혈전에 의한 흐름의 변이 등의 인체내의 저속유동을 검출하는 비침습적방법으로 유용하게 적용될 수 있을 것이다.

  • PDF

Slow Feature Analysis for Mitotic Event Recognition

  • Chu, Jinghui;Liang, Hailan;Tong, Zheng;Lu, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권3호
    • /
    • pp.1670-1683
    • /
    • 2017
  • Mitotic event recognition is a crucial and challenging task in biomedical applications. In this paper, we introduce the slow feature analysis and propose a fully-automated mitotic event recognition method for cell populations imaged with time-lapse phase contrast microscopy. The method includes three steps. First, a candidate sequence extraction method is utilized to exclude most of the sequences not containing mitosis. Next, slow feature is learned from the candidate sequences using slow feature analysis. Finally, a hidden conditional random field (HCRF) model is applied for the classification of the sequences. We use a supervised SFA learning strategy to learn the slow feature function because the strategy brings image content and discriminative information together to get a better encoding. Besides, the HCRF model is more suitable to describe the temporal structure of image sequences than nonsequential SVM approaches. In our experiment, the proposed recognition method achieved 0.93 area under curve (AUC) and 91% accuracy on a very challenging phase contrast microscopy dataset named C2C12.

Medical Application of Synchrotron Radiation in Japan

  • Toyofuku, Fukai;Tokumori, Kenji;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.32-34
    • /
    • 2002
  • Over the past two decades there has been a tremendous growth in the number of synchrotron radiation facilities in the world and also in Japan. The high flux and brightness radiation which derive from the third generation low emittance rings provide an ideal source for many applications in the medical sciences. The application of synchrotron radiation to medical imaging started in the early 80's in U.S.A, followed by European countries such as Germany and Russia. In Japan, researchs on intravenous coronary angiography started in 1884 at the Institute for High Energy Phisics(KEK) in Tsukuba. At present, it is the only application of syncrotron radiation which is at the stage of human study. In '90s, newer techniques such as phase and refraction contrast imaging appeared which are at the in vitro or animal study stage. Various types of x-ray CT have also been developed for three-dimensional imaging of the subjects. The present status of medical applications of synchrotron radiation in Japan is reviewed.

  • PDF

X선 위상차 가시화 기법을 이용한 GDI 인젝터 노즐 근방의 분무 간 상호간섭 해석 (Analyzing the Spray-to-spray Interaction of GDI Injector Nozzle in the Near-field Using X-ray Phase-Contrast Imaging)

  • 배규한;문석수
    • 한국분무공학회지
    • /
    • 제25권2호
    • /
    • pp.60-67
    • /
    • 2020
  • Despite its benefit in engine thermal efficiency, gasoline-direct-injection (GDI) engines generate substantial particulate matter (PM) emissions compared to conventional port-fuel-injection (PFI) engines. One of the reasons for this is that the spray collapse caused by the spray-to-spray interaction forms the locally rich fuel-air mixture and increases the fuel wall film. Previous studies have investigated the spray collapse phenomenon through the macroscopic observation of spray behavior using laser optical techniques, but it is somewhat difficult to understand the interaction between sprays that is initiated in the near-nozzle region within 10 mm from the nozzle exit. In this study, the spray structure, droplet size and velocity data were obtained using an X-ray imaging technique from the near-nozzle to the downstream of the spray to investigate the spray-to-spray interaction and discuss the effects of spray collapse on local droplet size and velocity distribution. It was found that as the ambient density increases, the spray collapse was promoted due to the intensified spray-to-spray interaction, thereby increasing the local droplet size and velocity from the near-nozzle region as a result of droplet collision/coalescence.

HRTEM영상 분석에 대한 IWFR 방법의 고찰 및 응용 (A Review of IWFR Method for HRTEM Image Analysis and Application)

  • 김황수
    • Applied Microscopy
    • /
    • 제38권1호
    • /
    • pp.63-72
    • /
    • 2008
  • Allen et al. (2004)에 의해 개발된 IWFR 방법에 대해서 응용성에 관심을 가지고 고찰되었다. 이 고찰에는 문헌에 보고된 GaAs, $YBa_2CuO_7$$Al_2CuMg$의 재료에 대한 HRTEM 연구물들이 이용되었다. 이 고찰 과정에서 이 방법의 타당성에 대한 이론적 근거, 제한조건 및 정보한계들을 명확히 제시되었다. IWFR 방법을 통해 얻은 결정 밑 표면에 전자 파동함수의 상(phase)-영상은 구면수차에 의한 영상 왜곡이 교정된 정보한계 범위 내에서 원자분해상을 나타낼 뿐만 아니라 결정의 구성원자의 원자번호에 대체적으로 비례하는 강도 분포를 나타내는 강한 경향이 있음이 특히 주목되었다.

전기화학적 에칭법을 이용한 AFM용 텅스텐 탐침 제작에 관한 연구 (Fabrication of Tungsten Probe Tips for AFM using Electrochemical Etching)

  • 한규범;장현아;안효석
    • Tribology and Lubricants
    • /
    • 제29권4호
    • /
    • pp.213-217
    • /
    • 2013
  • As commercial atomic force microscopy (AFM) probes made of Si and $Si_3N_4$ have low stiffness, it is difficult to induce sufficient elastic deformation on the surface of a specimen in a tapping mode. Therefore, high-guality phase contrast images can not obtained. On the other hand, a tungsten AFM probe has relatively higher stiffness than a commercial AFM probe. Accordingly, it is expected to provide an enhanced phase contrast image, which is an effective tool for achieving a better understanding of the micromechanical properties of worn surfaces and wear mechanisms. In this study, on electrochemical etching method was optimized to fabricate tungsten probe tips for an AFM. Electrochemical etching was performed by applying pulse waves with a 20% duty cycle at various voltages instead of only a DC voltage, which has been commonly used.

Detection of Active Intra-Abdominal Bleeding from Malignant Tumors in Two Dogs Using Contrast-Enhanced Ultrasonography

  • Nam, Jihye;Hwang, Jaewoo;Youn, Hwayoung;Choi, Mincheol;Yoon, Junghee
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.355-359
    • /
    • 2020
  • Contrast-enhanced ultrasonography (CEUS) has been applied to evaluate parenchymal organs in human and veterinary medicine. However, to our knowledge, there is no report on the identification of active bleeding and the bleeding site in veterinary clinical patients. Herein, we describe the use of CEUS in two cases of abdominal bleeding caused by ruptured lesions with malignant abdominal tumors. One dog had a splenic hemangiosarcoma, which had metastasized to the liver; the other dog had hepatic cell carcinomas in the left hepatic lobe, which were lobectomized, and another nodule was identified in the right hepatic lobe. Immediately after the rupture of these oncogenic lesions was suspected, CEUS was performed to identify the bleeding sites. The active bleeding sites were confirmed by hyperechoic pooling signs in the arterial phase, and extravasation could be observed within the defects showing hypoechoic perfusions in the delayed phase of the CEUS. Microbubbles were also observed in the ascites; thus, CEUS could detect the presence of hemorrhage and accurately identify the bleeding site. Collectively, the study findings suggest the usefulness of CEUS in emergent situations as it enables rapid and noninvasive evaluation of bleeding points in case of active bleeding in dogs.

적외선 열화상 이미지 컨트라스트 파라미터를 이용한 결함 크기의 비파괴 평가 (Nondestructive Evaluation of Defect Size by Using a Contrast Parameter of Infrared Image)

  • 최정영;최수용;김재연;유기태;박재원;현창용;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권1호
    • /
    • pp.87-94
    • /
    • 2018
  • Purpose: In this study, the defect quantification of thin metal plate was evaluated by using lock-in infrared thermography. Methods: A STS304 standard specimens, which had the artificial-defects of different size, were used. The focal distance between the infrared camera and the specimen was set to 500mm, and the distance between the lump and the specimen was set to 200mm. One halogen lamp with a maximum capacity of 1kW was used, and phase-lock infrared thermal images with a frequency of 1Hz were captured and analyzed. Result: Objectively quantified data values were obtained by analyzing the contrast ratio and signal-to-noise ratio. Conclusion: The possibility of defect diagnosis for thin metal plate was confirmed by using the lock-in infrared thermography technique.