• Title/Summary/Keyword: Contrast media(CM)

Search Result 27, Processing Time 0.023 seconds

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Contrast-Associated Acute Kidney Injury (CA-AKI) in Children: Special Considerations

  • Windpessl, Martin;Kronbichler, Andreas
    • Childhood Kidney Diseases
    • /
    • v.23 no.2
    • /
    • pp.77-85
    • /
    • 2019
  • Contrast-associated acute kidney injury (CA-AKI) is a major concern when iodinated contrast material is administered, especially in patients at risk. Efforts have been undertaken to understand the detrimental effects of contrast media (CM). With the use of low-osmolar or iso-osmolar CM the incidence of CA-AKI has steadily decreased within the past decade; however, especially in the pediatric population information is scarce. Incidence rates have been reported to range between 0% to 18.75%, particularly depending on indication, selection of population (i.e. preexisting co-morbidities), and definition of AKI. Different biomarkers have been proposed, but confirmatory studies are either lacking or have contributed to their lack of diagnostic power. Proteomic approaches have been employed and may pave the way to such discovery. Prevention strategies have been tested and proposed, but the recently published AMACING and PRESERVE trials have shown that commonly used strategies (such as systematic hydration or administration of N-acetylcysteine) have no role in the prevention of CA-AKI. We propose that thoughtful assessment of one's fluid state is the most appropriate approach and depending on the hydration status diuretics or fluid administration should be provided to achieve an euvolemic state ahead of contrast exposure.

Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media (요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.436-443
    • /
    • 2015
  • The purpose of this study was to develop a self-diagnostic linearity quality control techniques of computed tomography (CT) by using measured CT number values from the various concentrations of iodine contrast media (CM) is diluted with distilled water under each condition of the tube voltage. The equipment was used for four-channel MDCT, the iodine concentration were using 300 mgI/ml, 350 mgI/ml, 370 mgI/ml and 400mgI/ml. Dilution of CM in distilled water was increased by each 5% until the maximum CT number values were measured. We applied the tube voltages for 90 kVp, 120 kVp, 140 kVp. As a result, we was obtained to the nearest linearity as 0.993 of correlation coefficient between the iodinated CM from 5% to 25% in 400 mgI/ml and the CT number values by 90 kVp. In conclusion, the proposed self-diagnostic linearity quality assurance technique by using iodine CM can be utilized to replace the AAPM CT performance phantom.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

Studies of the side effects on using the contrast media: It's characteristic and management (조영제를 사용하는 환자의 부작용: 특성과 관리에 관한 연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.427-431
    • /
    • 2014
  • The purpose of this study is to monitor the current adverse reactions in administering CT contrast agents at general hospitals and also to suggest the practical guidelines to minimize the risk and to show the successful patient management. At four Dajeon city general hospitals, the contrast agents were administered in 646,828 cases and the overall prevalence of adverse reactions was 4,110 cases from January 2010 to December 2013. However, we excluded the two hospitals' 3,658 cases because the patients' data was inadequate. Consequently, the case surveys on the rest of 452 cases have been studied and submitted. After comparing the patients with a control group, we evaluated that the key factors of the adverse reactions were the gender and age difference of the patients, the examination period, the examination method, the quantity and administrating speed of the contrast agents. Even though the four general hospitals have their own management systems on adverse reactions, but their systems were not satisfying. To improve the quality of the management systems and to investigate further cases, some hospital administration procedures on the subject should be systemized and general hospitals should follow the recommended procedures. Moreover, the existing three-year-term evaluation should not only judge the adverse reaction management but also conclude some details on the sub criteria of the evaluation. The details on the sub criteria include the contrast agent characters, the quantity and administrating speed of the drug, the incidents' occurred time, an anamnesis; a case history, the medical history of the patients and the reaction occurring body parts, and the examination title. The details of the medical examiners are also added to the sub criteria.

A Study on the Heating of Lipiodol during Lymphangiography (림프관 조영술 시 리피오돌의 가온에 관한 고찰)

  • Kang, Rae-Wook;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.597-602
    • /
    • 2020
  • The study was conducted to improve the efficiency of the test and to reduce the exposure dose of patients and operators by analyzing the difference in the moving speed of Lipiodol according to the temperature during lymphography. The device for injecting Lipiodol at a constant pressure was self-made, and after inserting Lipiodol into the Connecting Tube, the moving speed of the contrast agent was photographed at temperatures of 26℃, 36℃, and 46℃ using a heat transfer device. Lipiodol movement time from the Support Catheter to 20cm was measured and analyzed, and statistical significance was confirmed. In the 46℃ environment, the average moving time was 11 seconds, at 36℃ the average was 13 seconds, and at 26℃ the average was 17 seconds. Lipiodol showed a significant difference in moving time with increasing temperature (p<.001), and it was confirmed that the higher the temperature, the faster the moving speed. In the case of lymphangiography, when heated to a certain temperature (46 degrees) rather than injecting Lipiodol at room temperature, the injection speed can be increased and the speed of movement in the lymphatic vessel can be improved.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

A Study on the Mode of Address and Meaning Creation of Underlight in Broadcasting Lighting (방송조명에서 언더라이트의 표현 양식과 의미 창출에 관한 연구)

  • Kim, Young-Jin;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.21 no.5
    • /
    • pp.749-759
    • /
    • 2016
  • As image contents in broadcasting have been created in HDTVs and monitors have been commercialized, facial expression of objects in broadcasting lighting has become a very significant task. Figure modeling of objects in HDTVs requires smoother and cleaner video images owing to the expansion of precision of image expression by light. Lighting methods that enlighten characters in the digital generation have come to require a new change. Character modeling methods used on expression features of underlight are receiving attention for aesthetic expression of figures in HD images. Accordingly, the influence of underlight light source intensity, distance, and size on character modeling characteristics was experimentally measured and comparatively analyzed. The experiment results show that good results can be obtained only when the intensity is 17%∼25.5% in contrast to total brightness, distance is beyond 40cm, and the size is at least 20cm, to exhibit the optimum effect of underlight. This data will become material with high usage to gain smoother and cleaner images of characters in future high-quality images.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF