• 제목/요약/키워드: Contrast agent

검색결과 371건 처리시간 0.035초

Iopamidol과 Ioversol 제제 조영제의 온도변화에 따른 물리화학적 분석 (Physicochemical Analysis according to Temperature Changes of Iopamidol and Ioversol Formulation Contrast Agents)

  • 한범희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.273-280
    • /
    • 2020
  • In this study, the P contrast agent of Iopamidol, which is a nonionic iodide contrast agent most commonly used as a vascular contrast agent in medical institutions, and the O contrast agent of Ioversol, were studied. The physicochemical changes according to the temperature change were compared and analyzed using the Bruker Avance 500MHz Nuclear Magnetic Resonance Spectrometer owned by the Korea Basic Science Institute (KBSI). There was no physical or chemical change in the O contrast medium of Ioversol formulation in temperature change. However, in the P contrast agent of Iopamidol, a doublet peak began to appear in the 1.1 ppm region of the sample at 60℃, and the doublet peak was clearly observed in the sample at 80℃. As a result of this study, 1H-NMR analysis revealed that the P contrast agent of the Iopamidol formulation was dissociated from chemical bonds as it rose to a high temperature of 60℃ or higher, resulting in the formation of foreign substances. It was evaluated that the O contrast agent of Ioversol formulation had physico-chemical stability than the P contrast agent of Iopamidol formulation. As shown in this study, it is necessary to analyze the physical and chemical changes of contrast agents according to various environmental factors.

Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Lee, Youngjin;Choi, Min Hyeok;Goh, Hee Jin;Han, Dong-Kyoon
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.281-285
    • /
    • 2016
  • The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가 (Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent)

  • 최관우;서성미;손순룡
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.5124-5130
    • /
    • 2014
  • 조영제의 희석률 변화에 따른 신호강도를 분석하여 조영증강 자기공명혈관조영검사 시 점도와 삼투압에 따른 부작용을 최소화하고 신호강도를 높여 영상의 질을 향상시키고자 하였다. 연구방법은 조영제가 혈관에 주입되면 혈액과 희석되어 mol 농도가 변화되고, 그에 따라 신호강도의 변화를 일으킴에 착안하여 phantom을 제작하였다. phantom 결과를 바탕으로 임상실험은 2013년 11월부터 2014년 1월까지 조영제를 희석한 군(30명)과 희석하지 않은 군(30명)으로 구분하여 뇌혈관의 신호강도를 비교하였다. 연구결과, 조영제 mol 농도 변화에 따른 phantom의 신호강도는 0.0125mmol부터 급격히 증가하다 20mmol에서 최고점을 이룬 후 200mmol부터 평형을 이루었다. 임상실험에서도 조영제를 희석하여 검사한 영상의 신호강도가 모두 높게 나타나, 1000mmol 조영제 사용에 비해 500mmol로 희석하여 사용함이 최고점인 20mmol에 근접하여 우수함을 알 수 있었다. 결론적으로 조영제를 희석하여 사용함으로써 점도와 삼투압을 저하시키고, 영상의 질을 향상시킬 수 있었으므로 임상적용의 유용성이 높다고 할 수 있다.

PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast agent for Attenuation Correction Using CT Scan in PET/CT System)

  • 손혜경;;권윤영;봉정균;정해조;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.100-103
    • /
    • 2004
  • 본 연구에서는 PET/CT시스템에서 CT영상을 이용한 감쇠 보정 시 조영제가 PET영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다. 모의실험을 위해 인체 기관 중 간을 가진 수학적 방출 스캔 맵과 투과 스캔 맵을 각각 만들었다. 간에서 조영제가 비 균일하게 증강된 투과 스캔 맵, 간에 조영제의 증강이 있는 투과스캔 맵과 없는 투과 스캔 맵, 간에 있는 종양에 조영제의 hypo-attenuating이 있는 투과 스캔 맵, 그리고 각각의 다른 조영제의 감쇠 정도를 가지는 간을 구현한 투과 스캔 맵을 각각 만들고 이를 이용하여 방출 영상을 감쇠 보정하였다. 팬텀실험을 통해 조영제의 농도에 따라 감쇠 정도가 달라짐을 확인하였다. 모의실험을 통해 감쇠 보정된 방출 영상이 조영제에 의해 영향을 받고, 또한 인공산물이 발생할 수 있음을 확인하였다. 따라서 조영제와 같은 물리적 인자가 감쇠 보정에 미치는 영향을 충분히 이해하고 정량적 분석 또는 진단 등에 고려하여야 할 것으로 생각한다.

  • PDF

뇌 혈관검사 시 적정 조영제량에 관한 연구 (A Study on the Optimum Amount of Contrast Media in Brain Angiography)

  • 김규형;이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향 (Impact of Contrast Agent for PET Images with CT-based Attenuation Correction)

  • 손혜경;;권윤영;정해조;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.192-201
    • /
    • 2005
  • 본 연구에서는 PET/CT 시스템에서 CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향을 관찰하기 위해 팬텀실험과 모의실험을 수행하였다. 다양한 농도로 희석한 조영제를 채운 플라스틱 병을 스티로폼을 이용하여 전신 팬텀 내에 고정시킨 후 투과 영상을 획득하였다 모의실험을 위해 인체 기관 중간을 가진 수학적 방출 맵과 투과 맵을 각각 생성하였다. 조영제의 비균일 증강, 조영제의 다양한 농도 및 분포 크기, 잡음 정도, 영상의 해상도, 재구성 알고리듬, 조영제의 저-감쇠, 그리고 각각 다른 시간상에 대한 조영제의 분포의 차이와 같은 다양한 인자들에 대하여 평가하였다. 팬텀실험으로부터 CT의 Hounsfield 값이 조영제의 농도 및 전압 값에 의존함을 확인할 수 있었다. 모의실험으로부터 조영제가 감쇠 보정한 PET 영상에서 인공산물을 생성하고 영상의 질을 떨어뜨리는 것을 관찰할 수 있었다. 조영제의 영향은 조영제의 농도 및 분포 크기, 잡음 정도, 영상의 해상도 등에 의해 영향을 받는 것으로 나타났다. 본 연구 결과들은 임상적 PET/CT 영상에서 조영제로 인해 발생할 수 있는 잠재적 문제를 충분히 이해하고 이를 고려해야 함을 보여 주었다.

  • PDF

하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구 (A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb)

  • 김상현
    • 디지털융복합연구
    • /
    • 제13권9호
    • /
    • pp.431-437
    • /
    • 2015
  • 하지 동맥 전산화단층촬영(CT) 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 효용성을 알아보고자 하였다. 조영제 125 cc 주입한 48명과 같은 양을 조영제와 생리 식염수를 7:3으로 주입한 30명을 대상으로 하였다. 각각의 영상에서 복부대동맥, 넙다리동맥, 오금동맥, 뒤정강동맥의 감쇄계수(HU)의 평균값과 신호 대 잡음비(SNR)를 정량적으로 평가 하였고, 정성적 평가는 영상의학과 전문의 2명, 방사선사 4명이 5점 척도로 4가지 평가항목을 평가하였다. 정량적 평가에서 HU와 SNR 모두 희석 전 평균값이 높게 나왔으나 독립표본 T검정에서 유의확률이 모두 p>0.05이므로 희석 전, 후의 통계적으로 유의성이 없다. 정성적 평가는 평균점수가 원액이 4.86~4.77, 희석액이 4.83~4.67로 차이가 있었으나, 유의확률이 모두 p>0.05이므로 희석 전, 후의 통계적으로 유의성이 없다. CT 하지동맥 조영 검사 시 일정 비율 희석한 조영제를 사용하여 기존 영상의 질을 유지 할 수 있고, 조영제의 총량을 줄여 단위 분자 당 요오드 함량이 낮아지므로 조영제로 인한 부작용을 줄일 수 있을 것으로 사료된다.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.