• Title/Summary/Keyword: Contrast

Search Result 13,826, Processing Time 0.043 seconds

Cognitive Contrast Enhancement of Image Using Adaptive Parameter Based on Non-Linear Masking (비선형 마스킹 기법 기반의 적응적 파라미터를 이용한 영상의 인지적 대비 향상)

  • Kim, Kyoung-Su;Kim, Jong-Sung;Lee, Cheol-Hee
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.11
    • /
    • pp.1365-1372
    • /
    • 2011
  • This paper proposes a cognitive contrast enhancement algorithm based on the non-linear masking to advance low cognitive contrast in dark regions of images. In order to improve brightness in dark regions of an image, we propose a new contrast enhancement algorithm based on the non-linear masking using regional adaptive parameters of an image. For performance evaluation of the proposed method, chromaticity and saturation comparison as a quantitative assessment and z-score comparison as a qualitative assessment were executed between test images and their simulated images by SSR, MSR, a conventional non-linear masking and the proposed method, respectively. As a result, the proposed method showed low chromaticity and saturation difference and improved cognitive contrast for the three methods.

Relationship between Contrast Ratio of Conductive Particle and Contact Resistance on COG Bonding using ACF (ACF를 이용한 COG 접합 공정에서 도전볼의 음영비와 접촉 저항과의 관계)

  • Jin, Songwan;Jeong, Young Hun;Choi, Eun Soo;Kim, Bosun;Yun, Won-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.831-838
    • /
    • 2014
  • Chip on glass (COG) bonding using anisotropic conductive film (ACF) is a key technology to assemble a driver IC onto a LCD glass panel. In this paper, an experimental investigation was conducted to investigate the correlation between contact resistance and characteristics of image taken by machine vision based inspection system. The results show that the contact resistance was strongly influenced by the contrast ratio of conductive particle rather than the number of conductive particles. Also, number of conductive particles whose contrast ratio is below 0.75 is crucial for determining the quality of the assembled samples. On the other hand, in the result of high temperature high humidity storage test, the contrast ratio of samples was increased. However, in the case of open-circuit samples after temperature humidity storage test, the number of conductive particles whose contrast ratio is above 0.75 was more than that of the closed-circuit samples.

Measurements of Sound Speed and Density Contrasts of the Moon Jellyfish (Aurelia aurita s.l.) for Hydroacoustic Model (수중음향 모델을 위한 보름달물해파리(Aurelia aurita s.l.)의 체내 음속비 및 밀도비)

  • Kang, Don-Hyug;Lee, Chang-Won;Lee, Hyung-Been;Kim, Mi-Ra
    • Ocean and Polar Research
    • /
    • v.34 no.1
    • /
    • pp.85-91
    • /
    • 2012
  • Physical properties such as sound speed contrast (h) and density contrast (g) of the interested target are key parameters to understand acoustic characteristics by using theoretical scattering models. The density and sound speed of moon jellyfish (common jellyfish, Aurelia aurita s.l.) were measured. Sound speed contrast (h) was measured from travel time difference (time-of-flight method) of an acoustic signal in a water tank for APOP studies (Acoustic Properties Of zooplankton). Density contrast (g) was measured by the displacement volume and wet weight (dual-density method). The sound speed remained almost constant as the moon jellyfish increased in bell length. The mean values${\pm}$standard deviation of h and g were $1.0005{\pm}0.0012$ and $0.9808{\pm}0.0195$), respectively. These results will provide important input for use in theoretical scattering models for estimating the acoustic target strength of jellyfish.

Radiological Diagnosis for Posttraumatic Olfactory Dysfunction (외상 후 후각이상에 대한 방사선학적 진단)

  • Ahn, Jung Yong;Joo, Jin Yang;Chung, Tae Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1570-1576
    • /
    • 2000
  • Objective : To evaluate objectively the sites of injury in patients with posttraumatic olfactory deficits and to suggest the diagnostic procedure for evaluation of posttraumatic anosmia. Methods : Ten patients with posttraumatic olfactory dysfunction were examined by means of olfactory testing, sinoscopy, contrast filled paranasal sinus computed tomography(contrast filled PNS CT) and magnetic resonance imaging(MRI). Five normal persons without olfactory dysfunction were also evauluated. The aerodynamic patency of olfactory cleft was examined by contrast filled PNS CT. The olfactory system(oflactory bulbs, olfactory tracts, inferior frontal region, hippocampi, or temporal lobes) was investigated in detail with MRI. The difference in the size of the olfactory bulb between normal volunteers and anosmic patients was evaluated by Student's t test. Results : Contrast filled dynamic CT scan was useful method for the evaluation of dynamic patency of the olfactory cleft. Paranasal CT scan of the all anosmic patients showed dynamic reflux of contrast media in olfactory cleft on valsalva maneuver. For the largest cross-sectional area and great height, the difference in olfactory bulb size between normal volunteers and patients was statistically significant(p<0.001) in MRI study. Conclusion : Posttraumatic anosmia was completely evaluated by olfactory testing, sinoscopy, and contrast filled CT scan for differentiation between conductive type and neurogenic type. Neurogenic anosmia was confirmed by perfect localization with MRI study.

  • PDF

Effect of the Cold-Warm Color Contrast of the Learning-Item on the Learner's Performance (학습항목의 한난 색채대비가 학습자의 학습수행에 미치는 영향)

  • Kim, Boseong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1442-1447
    • /
    • 2014
  • This study examined the effect of the cold-warm color contrast of the learning-item on the learner's performance. To do this, experimental conditions were divided into three conditions: control condition, cold-warm contrast condition of background and figure, and cold-warm contrast condition of distracter and target. In addition, the OSPAN (operation span) task was used as the learning task. As a result, the rate of word recognition was higher in cold-warm contrast condition of distractor and target than any other condition. These results could be interpreted as enhancing effect.

Prediction of the Effect of Defect Parameters on the Thermal Contrast Evolution during Flash Thermography by Finite Element Method

  • Yuan, Maodan;Wu, Hu;Tang, Ziqiao;Kim, Hak-Joon;Song, Sung-Jin;Zhang, Jianhai
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • A 3D model based on the finite element method (FEM) was built to simulate the infrared thermography (IRT) inspection process. Thermal contrast is an important parameter in IRT and was proven to be a function of defect parameters. Parametric studies were conducted on internal defects with different depths, thicknesses, and orientations. Thermal contrast evolution profiles with respect to the time of the defect and host material were obtained through numerical simulation. The thermal contrast decreased with defect depth and slightly increased with defect thickness. Different orientations of thin defects were detected with IRT, but doing so for thick defects was difficult. These thermal contrast variations with the defect depth, thickness, and orientation can help in optimizing the experimental process and interpretation of data from IRT.

Spreading Pattern of Epidurally-Administered Contrast Media in Rabbits (토끼에서 경막외강으로 투여한 조영제의 분포양상)

  • Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.231-234
    • /
    • 1997
  • Background: The aim of this study was to examine the precise spreading pattern of contrast media in small increments in rabbits. Following pentobarbital anesthesia, the epidural puncture was done surgically with a blunt hook. Methods: The tip of epidural catheter was located at the mid-portion of T7 and T12, in the T7 group (n=7) and T12 group (n=8), respectively. Injection of the contrast media was started at 0.1 mL/kg and increased by 0.1 mL/kg up to a maximum of 0.6, mL/kg, under fluoroscopy. Results: In both groups, the extent of spread increased continuously as a Starling resistor with increasing injected volume(T7 group: $y=4.0+41.8x-28.1x^2$, T12 group: $y=0.2+57.7x-43.5x^2$) the total spread of contrast media was similar. The contrast media spread equally, both rostral and caudal, from catheter tip in T7 group; media spread approximately twice as far rostral as compared to caudal in T12 group (P<0.05). Conclusions: In rabbits, the position of epidural catheter tip should be positioned 2~3 segments below the aimed segment in lower thoracic or lumbar region, whereas in mid-thoracic region it should be positioned close to the level of aimed segment. Rabbits have relatively small epidural space therefore, the volume of injectant should be carefully determined with the suggested equations of this study.

  • PDF

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

Contrast-enhanced Bias-corrected Distance-regularized Level Set Method Applied to Hippocampus Segmentation

  • Selma, Tisa;Madusanka, Nuwan;Kim, Tae-Hyung;Kim, Young-Hoon;Mun, Chi-Woong;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1236-1247
    • /
    • 2016
  • Recently, the level set has become a popular method in many research fields. The main reason is that it can be modified into many variants. One such case is our proposed method. We describe a contrast-enhancement method to segment the hippocampal region from the background. However, the hippocampus region has quite similar intensities to the neighboring pixel intensities. In addition, to handle the inhomogeneous intensities of the hippocampus, we used a bias correction before hippocampal segmentation. Thus, we developed a contrast-enhanced bias-corrected distance-regularized level set (CBDLS) to segment the hippocampus in magnetic resonance imaging (MRI). It shows better performance than the distance-regularized level set evolution (DLS) and bias-corrected distance-regularized level set (BDLS) methods in 33 MRI images of one normal patient. Segmentation after contrast enhancement and bias correction can be done more accurately than segmentation while not using a bias-correction method and without contrast enhancement.

Advanced Retinex Algorithm for Image Enhancement (영상 선명화를 위한 개선된 Retinex 알고리즘)

  • Cha, Hyo-Sang;Hong, Sung-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.29-41
    • /
    • 2013
  • The digital camera is impossible to preserve the appearance of a scene containing high dynamic range due to a limitations of the sensing hardware. The Retinex was proposed on the purpose to solve these problems. While the Retinex enhances visibility and color constancy, it sometimes suffers from color distortion, halo effect and reduced global contrast. This paper presents an advanced Retinex algorithm working on the YCbCr color coordinate to reduce the processing time and to improve the global contrast and color. Simulation results show that our algorithm significantly reduces the total processing time, and provide the superior result image by improving the global contrast and color consistency as well as by reducing the halo effect around the boundaries.