• 제목/요약/키워드: Continuous phase

검색결과 1,092건 처리시간 0.032초

재결정제어압연용 저탄소강의 연속냉각 상변태거동에 미치는 Nb 첨가효과 (Effect of Nb Addition on Phase Transformation Behavior during Continuous Cooling in Low Carbon Steels for Recrystallization Control Rolling)

  • 이상우;주웅용
    • 열처리공학회지
    • /
    • 제13권5호
    • /
    • pp.346-354
    • /
    • 2000
  • Effect of Nb addition on the phase transformation behavior was studied through continuous cooling transformation tests after reheating(reheating CCT) and deforming(deforming CCT) the 0.07%C-1.3%Mn-0.015%Ti-(0~0.08)% Nb steels. Transformation temperatures for deforming CCT were lower than those for reheating CCT, and the critical cooling rate for bainite transformation during deforming CCT was lower than that during reheating CCT. These enhanced hardenability for deforming CCT was considered to come from the sufficient solid solution of Nb in austenite during high temperature reheating before deformation. With Nb addition, the phase transformation temperature decreased, the bainite formation was enhanced, and the hardness of steel increased. Furthermore, these phenomena were more remarkable for deforming CCT than for reheating CCT. From the results, Nb-Ti bearing low carbon steel was considered to be a very favorable alloy system with good strength/toughness balance by recrystallization control rolling process.

  • PDF

고장력 냉연강판에서 미세조직에 대한 연속어닐링조건의 영향 (Effects of Continuous Annealing Parameters on Microstructures in a Cold-Rolled High Strength Steel)

  • 정우창
    • 열처리공학회지
    • /
    • 제17권5호
    • /
    • pp.283-292
    • /
    • 2004
  • The effects of the annealing parameters on microstructures were examined in a cold-rolled high strength steel containing 0.1% C, 0.5% Si, 1.5% Mn, and 0.04% Nb. It was impossible to avoid martensite in the microstructure even though the continuous annealing parameters were controlled. This indicates that the alloying elements such as silicon and manganese contributing to manganese equivalent($Mn_{eq}$) should be reduced to produce the ferrite-pearlite microstructure for the solid solution and precipitation hardened steel. It was found that a decrease in the rapid cooling temperature to $520^{\circ}C$ was effective to change the microstructure from ferrite-martensite to ferrite-pearlite-martensite. Typical dual-phase properties exhibiting a low yield ratio and a continuous yielding behavior were obtained when the rapid cooling temperature was in the range of $680^{\circ}C$ to $600^{\circ}C$. The critical volume fraction of martensite for the typical properties of dual-phase steel was about 11 percent.

막유화법에 의한 알지네이트 Microsphere의 제조 (Preparation of Alginate Microspheres Using Membrane Emulsification Method)

  • 염경호;최용한;다이엔 이 와일리
    • 멤브레인
    • /
    • 제14권3호
    • /
    • pp.218-229
    • /
    • 2004
  • SPG (Shirasu porous glass) 관형 막이 설치된 회분식 막유화 장치를 사용하여 단분산 칼슘 알지네이트 미립자를 제조하기 위한 막유화 공정변수의 최적조건을 결정하였다. 막유화의 공정변수로는 연속상에 대한 분산상의 비율, 알지네이트 농도, 유화제의 종류와 농도, 안정제 농도, 가교제 농도, 교반속도, 막간 압력차 및 SPG 막의 세공크기로 설정하고, 이들 변수가 제조된 알지네이트 미립자의 입자 크기와 분포에 미치는 영향을 검토하였다. 막유화의 공정변수들 중에서 연속상에 대한 분산상의 비율, 막간 압력차 그리고 알지네이트 농도가 증가할수록 미립자의 크기가 증가하였다. 반면 유화제의 농도, 교반속도 그리고 가교제의 농도가 증가할수록 미립자의 크기가 감소하였다. 세공 크기 $2.9{\mu}\textrm{m}$인 SPG막을 사용한 경우 막유화의 공정변수 조절을 통해 최종적으로 평균 입자 크기 $6{\mu}\textrm{m}$, 크기 분산도 1.1인 단분산 알지네이트 미립자의 제조가 가능하였다.

회전 막유화에 의한 알지네이트 미소 구체의 제조 (Preparation of Alginate Microspheres by Rotating Membrane Emulsification)

  • 민경원;염경호
    • 멤브레인
    • /
    • 제31권1호
    • /
    • pp.52-60
    • /
    • 2021
  • SPG (Shirasu porous glass) 원통형 막을 회전 시키는 회전 막유화를 사용하여 칼슘 알지네이트 미소 구체를 제조할 때, 단분산 미소 구체를 제조하기 위한 회전 막유화 공정변수들의 최적 조건을 결정하였다. 회전 막유화의 공정 변수로는 막의 회전 속도, 막간 압력차, 연속상에 대한 분산상의 비율, 알지네이트 농도, 유화제의 농도, 안정제 농도, 가교제 농도 및 막의 세공 크기를 설정하고, 이들 변수로 제조된 알지네이트 미소 구체의 크기와 단분산성에 미치는 영향을 검토하였다. 이 결과 회전 막유화의 공정 변수들 중에서 막모듈의 회전 속도, 유화제의 농도, 가교제의 농도가 증가 할수록 미소 구체의 크기가 감소하였으며, 반면에 연속상에 대한 분산상의 비율, 막간 압력차, 알지네이트 농도가 증가할수록 미소 구체의 크기가 증가하였다. 세공 크기 3.2 ㎛인 SPG막을 사용한 회전 막유화에서 공정변수 조절을 통해 최종적으로 입자 크기가 4.5 ㎛의 단분산 알지네이트 미소 구체의 제조가 가능하였다.

Study of Polymer Stabilized Continuous Director Rotation Mode

  • Kim, Sung-Ki;Kim, Dong-Woo;Choi, Hong;Shin, Hyun-Ho;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1225-1228
    • /
    • 2004
  • We have studied the Polymer Stabilized Continuous Director Rotation (PSCDR) mode to solve the thermal shock problem which is core and main problem in CDR mode. The cell filled 95wt. % R2301 FLC and 5wt. % UCL-001 polymer is applied a low DC voltage only near the phase transition temperature from cholesteric to chiral smectic C phase transition to get defect-free alignment. In the previous work, we also confirmed layer deformation induced by an applied DC field only near the phase transition temperature from Ch to $SmC^{\ast}$. Results of layer structure, and characteristics of electro-optical properties between CDR and PSCDR mode will be discussed in this paper. We are also in progress to finalize the layer structures compared between CDR and PSCDR mode by x-ray measurements.

  • PDF

Influence of a simple fracture intersection on density-driven multiphase flow

  • Seong-Hun, Ji;M.J., Nicholl;R.J., Glass;Gang-Geur, Lee
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.89-92
    • /
    • 2004
  • The influence of a single fracture intersection on density-driven immiscible flow is compared between wetting (water into air) and nonwetting (Trichloroethylene into water) flows. At low supply rates, the intersection acted as a hysteretic gate to pulsed flow of the wetting phase, but had minimal influence on nonwetting phase flow. For both cases, increasing the supply rate led to the formation of continuous fluid tendrils that crossed the intersection without interruption. The wetting experiment returned to pulsed flow as the supply rate was decreased, while the nonwetting experiment maintained a continuous flow structure. Results suggest a fundamental difference between wetting and nonwetting phase flows in fracture network.

  • PDF

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

Micro-PIV를 이용한 마이크로 튜브/채널 내에서의 혈장유동측정 (Measurements of Plasma Flows in Micro-Tube/Channel Using Micro-PIV)

  • 고춘식;윤상열;지호성;김경천
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.587-593
    • /
    • 2004
  • In this paper, flow characteristics of plasma flow in a micro-tube were investigated experimentally using micro particle image velocimetry(micro-PIV). For comparison, the experiments were repeated for deionized(DI) wale. instead of plasma. Both velocity profiles of plasma and do-ionized water are well agreed with the theoretical velocity distribution of newtonian fluid. We also carried out generating plasma-in-oil droplet formation at a Y-junction microchannel. In order to clarify the hydrodynamic aspects involved in plasma droplet formation, Rhodamine-B were mixed with plasma only for visualization of plasma droplet. With oil as the continuous phase and plasma as the dispersed phase, plasma droplet can be generated in a continuous phase flow at a Y-junction. For given experimental parameters, regular-sized droplets are reproducibly formed at a uniform flow conditions.

가변정도제어계의 Reaching Phase 및 chattering 현상의 제거에 관한 연구 (A Study of Method for Removing Reaching Phase and Chattering Phenomenon in Variable Structure Control Systems)

  • 주기호;송명현;박귀태;천희영
    • 대한전기학회논문지
    • /
    • 제36권1호
    • /
    • pp.52-57
    • /
    • 1987
  • In this paper, a methodology is developed to remove the reaching phase and the high frequency chattering phenomenon which are the common drawbacks of variable structrue control (VSC) system. A time varying switching surface is proposed to achieve sliding motion during the entire control process and a continuous control law whose terms are continuous functions inside a boundary layer neighbouring the time varying switching surface is developed to remove the high frequency chattering phenomenon of VSC. The methodology developed in this paper is applied to the 2'nd order time varying system and the simulated results are compared with those of typical VSC methodology.

  • PDF

비정렬격자계에서 과도 이상유동해석을 위한 수치해법 (HYDRODYNAMIC SOLVER FOR A TRANSIENT, TWO-FLUID, THREE-FIELD MODEL ON UNSTRUCTURED GRIDS)

  • 정재준;윤한영;김종태;박익규;조형규
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.44-53
    • /
    • 2007
  • A three-dimensional (3D) unstructured hydrodynamic solver for transient two-phase flows has been developed for a 3D component of a nuclear system code and a component-scale analysis tool. A two-fluid three-field model is used for the two-phase flows. The three fields represent a continuous liquid, an entrained liquid, and a vapour field. An unstructured grid is adopted for realistic simulations of the flows in a complicated geometry. The semi-implicit ICE (Implicit Continuous-fluid Eulerian) numerical scheme has been applied to the unstructured non-staggered grid. This paper presents the numerical method and the preliminary results of the calculations. The results show that the modified numerical scheme is robust and predicts the phase change and the flow transitions due to boiling and flashing very well.