• 제목/요약/키워드: Continuous flow system

검색결과 505건 처리시간 0.033초

Convection Heat Transfer Coefficient of a Meat Cube in a Continuous Flow Sterilizing System

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.328-333
    • /
    • 2005
  • Finite difference model and dynamic thermal property evaluation system were developed to estimate convection heat transfer coefficient by modeling temperature-time profile of beef cube in continuous flow sterilizing system. As input parameters of the model, specific heat and thermal conductivity values of beef frankfurter meat were independently measured from 20 to $80^{\circ}C$. Convection heat transfer coefficient was estimated by comparing simulated and measured temperature-time profiles. Actual temperature-time profiles of meat cube were measured at flow rates of 15, 30, and 45 L/min and viscosities from 0 to 15 cp, and mean values of convection heat transfer coefficients ranged from 792 to $2107\;W/m^2{\cdot}K$. Convection heat transfer coefficient increased with increase in flow rate and decreased as viscosity increased.

A Numerical Analysis of Molten Steel Flow Under Applied Magnetic Fields in Continuous Casting

  • Yoon, Teuk-Myo;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.2010-2018
    • /
    • 2003
  • Although continuous casting process has highly developed, there still remain many problems to be considered. Specifically, two vortex flows resulting from impingement against narrow walls make a flow field unstable in a mold, and it is directly related to internal and external defects of steel products. To cope with this instability, EMBR (Electromagnetic Brake Ruler) technique has been lately studied for the stability of molten steel flow, and it is revealed that molten steel flow in a mold can be controlled with applied magnetic field. However, it is still difficult to clarify flow pattern in an EMBR caster due to complex correlations among variables such as geometric factors, casting conditions, and the place and the intensity of charged magnetic field. In the present study, flow field in a mold is focused with different conditions of electromagnetic effect. To accurately analyze the case, three dimensional low Reynolds turbulent model and appropriate boundary conditions are chosen. To evaluate the electromagnetic effect in molten steel flow, dimensionless numbers are employed. The results show that the location and the intensity of the applied magnetic field significantly influence the flow pattern. Both impingement and internal flow pattern are changed remarkably with the change of the location of applied magnetic field. It turns out that an insufficient magnetic force yields adverse effect like channeling, and rather lowers the quality of steel product.

EMBR을 이용한 연속주조공정에서 난류 유동, 상변화 및 매크로 편석에 대한 연구 (Coupled Turbulent Flow, Heat and Solute Transport in Continuous Casting Processes with EMBR)

  • 강관구;유홍선;허남건
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1195-1200
    • /
    • 2004
  • A fully coupled fluid flow, heat, and solute transport model was developed to investigate turbulent flow, solidification, and macrosegregation in a continuous casting process of steel slab with EMBR. Transport equations of mass, momentum, energy, and species for a binary iron-carbon alloy system were solved using a continuum model. The electromagnetic field was described by the Maxwell equations. A finite-volume method was employed to solve the conservation equations associated with appropriate boundary conditions. The effects of intensity of magnetic field and carbon segregation were investigated. The electromagnetic field reduces the velocity of molten flow in the mold and an increase in the percentage of C in steel results in a decrease of carbon segregation ratio.

  • PDF

Yarn dyed wastewater treatment using hybrid electrocoagulation-Fenton method in a continuous system: Technical and economical viewpoint

  • Gunawan, Denny;Kuswadi, Vincensius Billy;Sapei, Lanny;Riadi, Lieke
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.114-119
    • /
    • 2018
  • Yarn dyed wastewater has to be treated prior to disposal into the water bodies due to its high content of harmful organic compounds. In this study, the performance of Chemical Oxygen Demand (COD) removal and kinetic rate constant are investigated via hybrid electrocoagulation-Fenton in a continuous system using wastewater discharged from a yarn dyed industry in Surabaya city. The wastewater was treated in a batch mode using electrocoagulation to reduce Total Suspended Solid, followed by Fenton method in a continuous system to reduce COD level. Various Fe(II) feeding modes, molar ratio of $Fe(II)/H_2O_2$, initial pH of wastewater, and flow rate are used in this study. The results show that COD removal process obeys a pseudo-first order kinetics. At $Fe(II)/H_2O_2$ ratio of 1:10, initial wastewater pH of 3.0, and feed flow rate of 30 mL/min, the COD removal efficiency was observed to be 80%, and the kinetic rate constant is $0.07046min^{-1}$. The chemical cost for the treatment estimated to be IDR 160 per L wastewater, which is cheaper than the previously reported batch system of IDR 256/L.

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.

처리분구별 하수발생 특성 조사 - A시 O, M 처리분구 - (Investigating Wastewater Flow Characteristics - O and M Treatment Basins of A City -)

  • 황병기
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.348-356
    • /
    • 2005
  • Water quality sampling surveys and continuous measurement of flow were conducted to identify wastewater flow characteristics for representative catchment of O and M treatment basins in A city. For HS-1 station representing commercial area, wastewater flow rises in the beginning of office-working hours, moves up and down within narrow range, and lasts till office-leaving hour, and falls gradually reflecting worker's returning home. However, in HS-2 station representing residential area, wastewater flow has two peaks, which are before office-going hour and after office-leaving hour. In residential area, the flow rate of weekends is higher than that of weekdays because it reflects population, being not contributed to generate wastewater during the working hours of weekdays, stay home and produce wastewater for weekends period. To determine the priority for rehabilitation of sewer system, infiltration rate was computed by dividing infiltration flow by mean diameter and total length of sewer, and HS-1 station ranked the first.

순환공정법(循環工程法)을 적용(適用)한 인공(人工) 사진폐액(寫眞廢液)으로부터의 전해채취(電解採取)에 의한 은(銀)의 회수(回收) (Recovery of Silver from Artificial Photographic Wastewater by Continuous Flow Electrolytic Process)

  • 정원주;김동수
    • 자원리싸이클링
    • /
    • 제16권1호
    • /
    • pp.68-72
    • /
    • 2007
  • 전기적 환원을 이용한 인공 사진폐수에서의 은 회수를 연속순환식 공정을 적용하여 환원시간 및 두 전극간의 전합 차, 농도유량에 따른 영향을 검토하였다. 은 함유 인공폐수 처리에 있어 적용(인가) 전압과 초기 농도가 증가함에 따라 제거율이 증가함을 보였다. 은 함유 인공폐수의 전해 반응 시, 음극에 환원 석출된 물질의 정성적인 분석을 위해 EPMA 및 XRD 분석 결과, 석출된 물질이 은임을 확인하였다.

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

접선류 방식의 막분리 공정에 있어서 분리기구 해석에 관한 연구 (A Study on Separation Mechanisms in Tangential Flow Membranes)

  • 이기정;허병기목영일
    • KSBB Journal
    • /
    • 제4권3호
    • /
    • pp.281-287
    • /
    • 1989
  • The experimental study reported herein was to investigate to separation characteristics of a tangential flow membrane in a continuous recycle situation. Physical and dynamic analyses are performed on the membrane system in order to relate relevant variables to the capacity of separation. The results of separation process may be summarized by a proposed equation:Sh=A(Re.Sc.dh/L)1/3. It was shown also by the analyses that effective separation of sugar and cell was attainable by means of tangential membranes, thereby enhancing ethanol productivity in fermentation with continuous cell and substrate recycle.

  • PDF

신호 흐름 그래프에 의한 샘풀된 데이터계통의 해석 (Analysis of Sampled-data Systems by Signal Flow Graphs)

  • 박상희
    • 전기의세계
    • /
    • 제19권5호
    • /
    • pp.1-7
    • /
    • 1970
  • Starting from the review of signal flow graphs and flow graphs, this paper gives an example of sampled-data systems for Sedlar & Bekey's formulation. In this purpose it discussed the difference between Mason's signal-flow graphs and Coates flow graphs for drawing th flow graph of a linear system, and then a new flow-graph symbol introduced in order to distinguish between continuous and discrete systems. Thus, the paper is analysed and compared with a sampled-data systems between conventional methods and new method of signal flow graphs.

  • PDF