• Title/Summary/Keyword: Continuous flow system

검색결과 505건 처리시간 0.029초

개방된 2상 자연순환 회로내의 유동특성에 관한 실험적 연구 (An Experimental Study on the Flow Characteristics Inside an Open Two-Phase Natural Circulation Loop)

  • 경익수;이상용
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1313-1320
    • /
    • 1993
  • 본 연구에서는 가시화가 가능한 상승부를 가진 개방된2상 자연순환 회로를 설치하여 각 운전 조건에 따른 순환 유동 특성을 살펴보았다. 즉, 가열량 증가에 따 른 상승부에서의 2상 유동 양식의 변화를 관찰하였고 동시에 가열기 입구 과냉 액체의 순환 유속 및 상승부의 기공률(void fraction)을 측정하였다. 또한 가열기 입구 및 출구에 설치된 밸브의 마찰저항, 가열기 입구 액체의 과냉 정도, 그리고 충전수위등이 전반적인 유동특성에 미치는 영향을 연구하였다.

불연속 오일공급 크랭크샤프트 시스템을 채택한 엔진 윤활시스템의 해석 (A Study on the Engine Lubrication System Analysis Adapting Discontinuous Oil Supply Crankshaft System)

  • 윤정의
    • Tribology and Lubricants
    • /
    • 제20권1호
    • /
    • pp.27-32
    • /
    • 2004
  • This paper presents unsteady oil flow behaviors in the engine lubrication network to clarify the differences between continuous and discontinuous oil supply crankshaft system. Using commercial network analysis program, Flowmaster2, engine lubrication network system analysis were carried out. And effects of crankshaft speed and supplied oil pressure on pressure fluctuation in oil groove and oil flow rate to each bearing were analyzed.

Effects of Medical O2O Platform Quality Components on Continuous Use Intention to Information Distribution

  • MYUNG, Ju-Dong;KIM, Bo-Young
    • 유통과학연구
    • /
    • 제20권10호
    • /
    • pp.105-117
    • /
    • 2022
  • Purpose: The digital healthcare business is rapidly growing due to the COVID-19 pandemic, and the medical service platform business based on smartphone apps is globally expanding. This study targeted medical information online to offline (O2O) platform users in the medical service field. It verified the effect relationship revealed in the continuous use intention of the platform with the mediation of platform quality components, namely perceived benefits, flow experience, and use satisfaction. Research design, data and methodology: Based on previous studies, three medical information O2O platform quality components, namely system quality, information quality, and service quality, were defined. And the questionnaire survey was carried out targeting 359 leading medical information O2O platform users in Korea. Results: As a result of the analysis, it was confirmed that system quality and service quality had a positive (+) effect on satisfaction and continuous use intention with the mediation of perceived benefits and flow experience. Meanwhile, information quality had a negative effect (-) on perceived benefits and flow experience and did not affect use satisfaction and continuous use intention. Conclusions: Consequently, it was ascertained that the system quality and service quality affecting user behavior and experience were more significant factors than information quality to medical information O2O platform users from the medical service aspect.

COMPLEXITY OF CONTINUOUS SEMI-FLOWS AND RELATED DYNAMICAL PROPERTIES

  • Zhang, Feng;He, Lian-Fa;Lu, Qi-Shao
    • 대한수학회지
    • /
    • 제46권2호
    • /
    • pp.225-236
    • /
    • 2009
  • The equicontinuity and scattering properties of continuous semi-flows are studied on a compact metric space. The main results are obtained as follows: first, the complexity function defined by the spanning set is bounded if and only if the system is equicontinuous; secondly, if a continuous semi-flow is topologically weak mixing, then it is pointwise scattering; thirdly, several equivalent conditions for the time-one map of a continuous semi-flow to be scattering are presented; Finally, for a minimal continuous map it is shown that the "non-dense" requirement is unnecessary in the definition of scattering by using open covers.

연속류형 Micro-PCR 시스템의 설계 (Design of Continuous-flow Micro-PCR System)

  • 김덕종;김재윤;박상진;허필우;윤의수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.115-120
    • /
    • 2003
  • In this work, a continuous-flow micro-PCR system is systematically designed. From the numerical simulation based on the finite volume method, adapting oneself to a new environmental temperature without an external temperature controller is shown to be possible and a cooler as well as a heater is shown to be necessary to obtain three individual temperature zones for polymerase chain reaction. In addition, appropriate geometry of a heat sink for the cooler is determined by using a compact modeling method, the porous medium approach.

  • PDF

컴퓨터 시각에 의한 고형 입자의 소량 유동율 측정장치 개발 (Development of a Computer Vision System to Measure Low Flow Rate of Solid Particles)

  • 이경환;서상룡;문정기
    • Journal of Biosystems Engineering
    • /
    • 제23권5호
    • /
    • pp.481-490
    • /
    • 1998
  • A computer vision system to measure low flow rate of solid particles was developed and tested to examine its performance with various sized 7 kinds of seeds, perilla, mung bean, paddy, small red bean, black soybean, Cuba bean and small potato tuber. The test was performed for two types of particle flow, continuous and discontinuous. For the continuous flow tested with perilla, mung bean and paddy, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method about 0.98. Average errors of the computer vision measurement were in a range of 6∼9%. For the discontinuous flow tested with small red bean, black soybean, Cuba bean and small potato tuber, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method 0.98∼0.99. Average errors of the computer vision measurement were in a range of 5∼10%. Performance of the computer vision system was compared with that of the conventional optical sensor to count particles in discontinuous flow. The comparison was done with black soybean, Cuba bean and small potato tuber, and resulted that the computer vision has much better performance than the optical sensor in a sense of precision of the measurement.

  • PDF

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구 (A Study on the Development of CW(Continuous-Wave)Doppler System for measuring Bi-directional Blood Flow Information)

  • 강충신;김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권1호
    • /
    • pp.75-80
    • /
    • 1987
  • With the conventional CW Doppler velocity meter, bl-directional velocities cannot be separated. The new CW Doppler system uses quadrature detection and phase rotation to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, we can easily differentiate typical artery flow from vein flow, and measure both velocity characteristics qualitatively.

  • PDF

Sensitivity of Hot Film Flow Meter in Four Stroke Gasoline Engine

  • Lee, Gangyoung;Lee, Cha--Myung;Park, Simsoo;Youngjin Cho
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.286-293
    • /
    • 2004
  • The air fuel ratios of current gasoline engines are almost controlled by several air flow meters. When CVVT (Continuous Variable Valve Timing) is applied to a gasoline engine for higher engine performance, the MAP (Manifold Absolute Pressure) sensor is difficult to follow the instantaneous air fuel ratio due to the valve timing effect. Therefore, a HFM (Hot Film Flow Meter) is widely used for measuring intake air flow in this case. However, the HFMs are incapable of indicating to reverse flow, the oscillation of intake air flow has an negative effect on the precision of the HFM. Consequently, the various duct configurations in front of the air flow sensor affect the precision of HFM sensitivity. This paper mainly focused on the analysis of the reverse flow, flow fluctuation in throttle upstream and the geometry of intake system which influence the HFM measurement.