• Title/Summary/Keyword: Continuous Power Supply

Search Result 175, Processing Time 0.025 seconds

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Analysis of the Operational Characteristics of Superconducting Power supply Considering the structure of the Sheets (박막구조에 따른 초전도전원장치의 동작특성 해석)

  • Kim, Ho-Min;Yoon, Yong-Soo;Ahn, Min-Cheol;Ko, Tae-Kuk;Han, Tae-Su;Oh, Sang-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.164-169
    • /
    • 2001
  • This paper deals with comparison of characteristics of continuous-sheet type low-Tc superconducting (LTS) power supply and discrete-sheet type LTS power supply. These characteristics have been analyzed through experiments. These power supplies consist of two exciters, a rotor, a stator, and a LTS load. A continuous-sheet type has a single continuous niobium (Nb) sheet attached to the inner surface of on the stator. In the case of discrete-sheet type, four separated Nb sheets are used. this experiment is using 1.81 mH LTS magnet load and maximum 30 A dc exciter current. A discrete-sheet type is expected to produce much better pumping rate than a continuous-sheet type. The experimental observations have been compared with the theoretical predictions. In this experiment, the maximum pumping-current has reached about 926 A.

  • PDF

Boost Input type High Power Factor Resonant Power Supply for driving Magnetron Device (마그네트론 구동용 고역률 부스트 입력 방식의 공진형 전원장치)

  • Jeong, Jin-Beom;Yeon, Jae-Eui;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1078-1080
    • /
    • 2003
  • This paper proposes the boost input type resonant power supply for driving the magnetron device of the high-capacity microwave oven. Circuit topology of the proposed power supply is the boost input type resonant converter which uses the resonance between transformer leakage inductance and resonance capacitance. Proposed power supply obtains high power factor more than 98% through continuous current mode pulse width modulation. To verify the validity of the proposed power supply, operation principle in the steady state is analyzed and experimental results are presented.

  • PDF

Electronic Circuit Design for Portable Infrared Night Vision Scope (휴대용 적외선 야시경을 위한 전자회로설계)

  • Eom Ki-Hwan;Kim Doo-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.2 s.308
    • /
    • pp.33-39
    • /
    • 2006
  • This paper designed the electronic circuit part of Potable Infrared Night Vision Scope for a small size, light weight, and low power. Designed electronic circuit part is composed of an Auto Voltage Selecting Module, and a Power Supply Module. An Auto Voltage Selecting Modulo is composed of a switch, a battery, a step up voltage part, and a selecting voltage part. A Power Supply Module is composed of a high luminous sensing part, a battery voltage sensing part, a infrared illumination part, a connection sensing part, and a power control part. And this module controls the power of Image Intensifier Tube. To verify the performance of the designed electronic circuit part, we experimented the consumption power and continuous using time. Experimental results show that the designed electronic circuit part improves considerably on the performance of the AN/PVS-14. performance.

Analysis of continuous conduction mode boost power-factor-correction circuit (부스트 방식 역률개선회로의 설계와 특성분석)

  • Kim, Cherl-Jin;Jang, Jun-Young;Kim, Sang-Duck;Song, Yo-Chang;Yoon, Shin-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1120-1122
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor improvement and harmonic reduction technique is very important in switching power supply. The power factor correction (PFC) circuit using boost converter used in input of power source is studied in this paper. It is analyzed distortional situations and harmonics of input currents that presented at continuous conduction mode(CCM) of boost PFC circuit. It is done simulations of harmonics distribution according to load variation by using PSPICE and MATLAB. From the actual experiment of boost PFC circuit the validity of the analysis is confirmed.

  • PDF

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

  • Bachmann, G.;Wimmer, D.
    • International Journal of Railway
    • /
    • v.1 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Reliability of onboard power supply systems on rolling stock is a very important issue for the railway operator. While a failure of the HVAC supply results in a loss of comfort for the passengers, a failure of the supply for air compressors or for the traction cooling systems results in towing the train. This is, looking at the required availability of a train, not acceptable. An active redundancy concept for the onboard power supply maximizes the availability of the system. This paper describes such a system under the aspect of $\cdot$ Weight reduction $\cdot$ Continuous operation when changing from normal to redundant operation $\cdot$ Flexibility in train design.

  • PDF

Resonant Converter System for Control Power Supply (제어용 전원으로 사용가능한 공진형 컨버터 시스템)

  • Ji Jun-Keun;Lim Young-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.69-72
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for control power supply is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(parallel output series resonant) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Language) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

Multi-Objective Optimization Model of Electricity Behavior Considering the Combination of Household Appliance Correlation and Comfort

  • Qu, Zhaoyang;Qu, Nan;Liu, Yaowei;Yin, Xiangai;Qu, Chong;Wang, Wanxin;Han, Jing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1821-1830
    • /
    • 2018
  • With the wide application of intelligent household appliances, the optimization of electricity behavior has become an important component of home-based intelligent electricity. In this study, a multi-objective optimization model in an intelligent electricity environment is proposed based on economy and comfort. Firstly, the domestic consumer's load characteristics are analyzed, and the operating constraints of interruptible and transferable electrical appliances are defined. Then, constraints such as household electrical load, electricity habits, the correlation minimization electricity expenditure model of household appliances, and the comfort model of electricity use are integrated into multi-objective optimization. Finally, a continuous search multi-objective particle swarm algorithm is proposed to solve the optimization problem. The analysis of the corresponding example shows that the multi-objective optimization model can effectively reduce electricity costs and improve electricity use comfort.

Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System (건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.