• 제목/요약/키워드: Continuous Device

검색결과 593건 처리시간 0.022초

Custom-Made ITE Type Hearing Protection Device Using a Small Acoustic Filter

  • Lee, Yun-Jung;Kim, Pil-Un;Jung, Young-Jin;Chang, Yong-Min;Cho, Jin-Ho;Kim, Myoung-Nam
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권6호
    • /
    • pp.376-383
    • /
    • 2006
  • Noise induced hearing loss (NIHS), the well-known occupational disease, is caused by continuous excessive noise. The prevention of NIHS is very important, because it is unrecoverable. There are some kinds of hearing protection device (HPD), and those are effective in preventing NIHS. But workers in noisy environment often resist to wearing them. Because they are ready - made products, so workers feel uncomfortable to wear. Also, they didn't maintain the conversation frequency range, so workers are hard to communicate in wearing them. To prevent hearing loss effectively, it is important that workers keep wearing HPD. Therefore, a HPD is needed to be comfortable to wear and be effective not only in hearing protection but also in preserving communication ability. So we proposed a custom - made hearing protection device in which a small acoustic filter is inserted. We designed several kinds of small acoustic filters and carried out some acoustic experiments for measuring characteristics of filters. We confirmed that acoustic transmission characteristic can be adjusted from experimental results using designed small acoustic filters. And we researched for the actual efficiency of a new developed custom - made hearing protection device using a small size acoustic filter. Also, we found out that workers are more satisfied with the new development than a former protection device from a workers' response.

불명확한 공정정보 처리를 위한 퍼지-통계적 관리도의 개발 (Development of Fuzzy-Statistical Control Chart for Processing Uncertain Process Information)

  • 김경환;하성도
    • 한국정밀공학회지
    • /
    • 제15권2호
    • /
    • pp.75-80
    • /
    • 1998
  • Process information is known to have the continuous distribution in many manufacturing processes. Generalized p-chart has been developed for controlling processes by classifying the information characteristics into several groups. But it is improper to describe continuous processes with the classified process informal ion, which is based on the classical set concept. Fuzzy control chart, has been developed for the control of linguistic data, but it is also based on the dichotomous notion of classical set theory. In this paper, fuzzy sampling method is studied in order to process the uncertain data properly. The method is incorporated with the fuzzy control chart. Statistical characteristics of the fuzzy representative value are utilized to device the fuzzy-statistical control chart. The fuzzy-statistical control chart is compared with the generalized p-chart and both the sensitivity to the process information distribution change pared robustiness against the noise on the process information of the fuzzy-statistical control chart are shown to be superior.

  • PDF

밀도 차를 이용한 경액과 중액의 연속 순간 원심분리기 개발 (Development of the Continuous and Instantaneous Light liquid-Heavy liquid Centrifugal Separator using Density Difference)

  • 김영환;윤지섭;정재후;홍동희;박기용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.655-659
    • /
    • 2001
  • Resident time of the continuous and Instantaneous centrifugal separator using that separates the light and heavy liquids by use of density difference is the orptical factor that affects significantly the chemical metial extraction and the productivity in the chemical and mechanical process. In this paper, the overflow of the device is investigated under consideration of the relationships between inclination angle of liquid feeding screw and the centrifugal force. From the design of the length of a centrifugal separator, the radiuses of rotor and housing, theoretical formulation on the contact radius of separation weir is established through the experiments. From the experiments, it is identified that how much the capacity of inlet impeller and the emulsion phenomenon depend on the screw angle of inlet impeller. Also, we investigate the separation condition and the resident times that are functions of the phase ratio and density.

  • PDF

에밀레 종소리에서 아기 울음소리의 성분 분석에 관한 연구 (A Study on the Characteristic Analysis of Baby's crying the sound of Emille bell)

  • 최성영;손정호;배명진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2152-2155
    • /
    • 2003
  • Divine bell of king Songdok(3.663m of the height, 2.227m of the diameter, 18,900kg of the weight, 7.7-21.5mm of the thickness), known as the bell of Emille which has been molded in 771 year to the illustrious memory of King Songdok for 34 years is one of culture heritages in the world. Even though the appearance of bell is very beautiful, also the sound of bell was appeared miraculous characteristics of shaking the sky, earth and human. The bell of Emille caused by discontinuous sound in maintaining continuous, strongly emotional sound and moving the mind of human etc, is appeared the 'Macnorlee' phenomenon which having the discontinuous sound in maintaining continuous. So far, it has reasoned out the phenomenon of the bell of Emille. but it was first proved a realized a baby-boiling sound about the bell of Emille according to the comparison and analysis. In this study of bell, we proposed improvement and device of the wooden parts beating the bell why a baby-boiling sound was not heard well as before.

  • PDF

멤스 기반의 캔틸레버 형 전극을 가진 마이크로 디바이스를 이용한 단일세포의 Electroporation 및 유전자 Transfection (Single-cell Electroporation and Gene Transfection using MEMS-based Microdevice with Cantilever-type Microelectrode)

  • 조영학;김범준
    • 한국정밀공학회지
    • /
    • 제27권5호
    • /
    • pp.85-91
    • /
    • 2010
  • In this paper, we present details on fabrication of single-cell electroporation microdevice, practical experiments of single-cell electroporation with our fabricated microdevice. Also, the continuous electroporation for the continuous flow of cells is used for high-throughput electroporation. The delivery efficiency and cell viability tests are provided and the successful GFP transfection into cells is also evaluated with a fluorescent microscope after electroporation. This device enables to reduce the size of samples and thus the use of small amount of reagents. Also, it makes it possible to permit to avoid cell discrimination (transfected cells versus non-transfected cells) encountered when traditional bulk electroporation is held.

연속주조기 Mold Oscillation 진단시스템 개발 (Development of Diagnostic System for Mold Oscillation in a Continuous Slab Casting Machine)

  • 이성진;전형일;이경순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.387-392
    • /
    • 2002
  • A portable mould oscillation analyzer with an integrated computer, developed by POSCO, records the movement of the mould in every spatial direction. The system uses the gap sensors to measure the mould movement (displacement) in two horizontal directions according to the mould narrow and broad faces and the vertical strokes in the four corners of mould. The gap sensor is a non-contacting minute displacement-measuring device using the principle of high frequency eddy current loss. The mould oscillation diagnostic system integrates the gap sensors, their converters and the industrial portable computer with plug-in data acquisition boards. In an own expert module, which is included in the diagnosis program, one can obtain much information about the mould oscillation equipment.

  • PDF

Modal Analysis of Point and Discretized Continuous Spectra for Metal-Insulator-Metal Waveguides in the Terahertz Region

  • Hur, Jun;Choo, Hosung;Park, Jong-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1644-1654
    • /
    • 2018
  • Eigenvalue distributions for a periodic metal-insulator-metal waveguide, classified into the point spectrum and the discretized continuous spectrum (DCS), are investigated as functions of frequencies, gap widths, and periods. Muller's method is suggested for solving exact eigenvalues, and we propose the scheme for finding proper initial values in the Muller's method by considering only ${\Re}e({\varepsilon}_r)$ in the dispersion equation. We then find that anti-crossing behavior, repulsive effect between the point spectrum and the DCS, becomes stronger when the real parts of the roots in the point spectrum have smaller values. Finally, we examine the transmittances of a single subwavelength slit for real metals using the mode matching technique. The transmittances in real metals similarly follow those of the perfect electric conductor (PEC) at low frequencies, while the patterns at higher frequencies begin to differ from the PEC.

A356 합금의 연속주조시 전자기 교반에 따른 미세조직 변화 (The Effect of Electromagnetic Stirring on the Microstructure of A356 Al Alloy by the Continuous Casting Process)

  • 김원배;권태우;김종철;박태호;예병준
    • 한국주조공학회지
    • /
    • 제25권4호
    • /
    • pp.156-160
    • /
    • 2005
  • There are many factors that influence solidification behavior during continuous casting, e.g. include superheat, casting speed, cooling rate and holding time. However, when melt is stirred by electromagnetic force, there would be some changes in its solidification behavior compared to that of the ordinary casting process. In this study, the billets of A356 alloy with a diameter of 3 inch were fabricated with electromagnetic stirring under various conditions of superheat, casting speed and input voltage of electro magnetic stirring (EMS) device. The microstructure was also investigated under the various casting conditions and electromagnetic input voltages. When increase in input voltage, the microstructure was changed from dendritic to rosette type and finally to spheroidal. With pouring temperature, casting speed and electromagnetic input voltage were $650^{\circ}C$, 100 mm/min and 140 V, respectively, the billet with a diameter of 3 inch, which has a uniform dispersed spheroidal particles in the whole area of billet except for the surface area, was manufactured.

지속적 신대체요법 시 도식화된 알람 관리 매뉴얼 사용이 중환자실 간호사의 알람 해결률과 간호수행능력에 미치는 효과 (Effects of the Schematized Alarm-managing Manual for Continuous Renal Replacement Therapy on the Alarm Resolution Rate and Nursing Competence of Nurses in Intensive Care Units)

  • 최앵자;이영희
    • 간호행정학회지
    • /
    • 제20권5호
    • /
    • pp.535-544
    • /
    • 2014
  • Purpose: This study was done to develop a schematized alarm-managing manual for continuous renal replacement therapy (CRRT) and to investigate its effects in maintaining continuity in the patients' treatment and promptly resolving alarms when CRRT is being carried out. Methods: Sixtynurses from two medical intensive care units (ICUs) (one experimental and one control) at one hospital were asked to answer a questionnaire including their CRRT nursing competency and satisfaction with the manual. Data on alarm resolution rate were collected by analyzing existing data, such as the details of each alarm and the number of resolutions around the clock in the CRRT device. Results: The alarm resolution rate and some of CRRT nursing competency scores in the experimental group were higher than those in the control group. The experimental group was also satisfied with the manual. Conclusion: The study confirmed that the schematized alarm-managing manual can be useful for ICU nurses to resolve alarms and can be used as a guideline. Application of this manual to clinical practices and its use can therefore, be encouraged through continuous education and promotion.

제주도 연안 연속식 갈치채낚기 조획시스템의 개량에 관한 기초적 연구 (A basic study on the improvement of the continuous type fishing system for largehead hairtail hand line in coastal area of Jeju island, Korea)

  • 김병엽;이창헌
    • 수산해양기술연구
    • /
    • 제45권1호
    • /
    • pp.14-21
    • /
    • 2009
  • This experimental study was carried out to obtain the base data for saving the man power in the fishing operation of largehead hairtail hand line by using the continuous type hand line system with a rotary device which could make a main line move automatically. In order to solve the twists and entangling on the main line happened during operating test, the resistance board was suspended at the end of the main line at sea. As the result, there were no problems of tangling and so on due to up and down moving of a main line. According to the control of a fixed angle of guide roller, it was possible to prevent the main line to be separated from a side roller and a guide roller. In addition, PVC tube between a guide roller and a side roller enabled a main line to be moved smoothly without any entanglement.