• Title/Summary/Keyword: Contamination check

Search Result 67, Processing Time 0.024 seconds

Convergence Study on Sterilized Dental Instruments Expiration Date (멸균된 치과기구의 유효기간에 관한 융합연구)

  • Na, Jae-Gyeong;Park, Hae-Ryeon;Sung, Hye-Lin;Song, In-Ha;Joo, Jung-Hwan;Kang, Kyung-hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.129-135
    • /
    • 2018
  • This study aimed to investigate the contamination rate of microorganisms by times after sterilization in mirrors, dental explorers, and pincettes which are the basic tools used in the dental clinic. 60 samples by each tool were used upon packaging them by 10 units. Contamination rate of microorganisms were tested using dry film media(3M Petrifilm Plates) which is a quick check upon collecting 10 samples right after sterilization, at Week 2, 3, 4, 5, and 6. At Week 0 when was right after sterilization, no microorganism was detected in any tools while they were detected in 2 mirrors, 2 dental explorers, and 2 pincettes at Week 6. 2 to 4 colonies on average were detected in mirrors at Week 2 and 4, 1 to 2 colonies in explorers from Week 5, and no colony was found in pincettes until Week 5 but 1 to 2 colonies at Week 6. Based on these results, the needs of effective periods are suggested for the sterilized tools together with their safe usages.

Sialoglycoproteins of Mammalian Erythrocyte Membranes: A Comparative Study

  • Sharma, Savita;Gokhale, Sadashiv M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.12
    • /
    • pp.1666-1673
    • /
    • 2011
  • The presence of sialoglycoproteins (SGPs) in the membranes from goat (Capra aegagrus hircus), buffalo (Bubalus bubalis bubalis) and pig (Sus scrofa domestica) erythrocytes was investigated by partial purification with a chloroform-methanol extraction method followed by Sodium dodecyl sulphate - Polyacrylamide gel electrophoresis in comparison to human (Homo sapiens) erythrocytes. The results show that mammalian erythrocytes possess clear differences in the SGPs numbers and molecular weights although all animals studied in this experiment are from the same class i.e. mammalia. The SGPs number in human, goat, buffalo and pig are four (PAS-1 to PAS-4), ten (PAS-GI to PAS-GX), seven (PAS-BI to PAS-BVII) and four (PAS-PI to PAS-IV) respectively as indicated by staining the polyacrylamide gel with sialoglycoprotein-specific Periodic acid-Schiff's (PAS) stain. The new SGPs could be observed only after the partial purification of membrane fractions named as PAS-HI with molecular weight (Mr) 190 kDa and PAS-HII 150 kDa in human, PAS-BIA in buffalo and PAS-PIA and PAS-PIVA in pig. The gels were also stained with Coomassie brilliant blue (CBB) and Silver stain to check the contamination of other membrane proteins in the purified fractions. The quantitative distribution of SGPs was also determined by densitometry. Present study indicates that there are some basic differences in mammalian erythrocyte membrane SGPs, especially with respect to their number and molecular weights indicating major structural variations.

Occurrence of severe soybean-sprout rot caused by Pythium deliense in the recirculated production system

  • Yun, Sung-Chul
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.92.2-93
    • /
    • 2003
  • Severe soybean-sprout rot was found at the mass productive factory in 2000 and 2001 and it caused 10-20% loss of the production. Pythium sp. was isolated almost 90% by potato dextrose agar from rotted root and hypocotylsof the sprouts. And the pathogencity tests using test tubes with 2% water agar and small containers (30 ${\times}$ 30 ${\times}$ 50 cm, WxLxH) cultivation were shown a similar rot on roots and hypocotyls. The fungal mycelium grew rapidly on the water agar and it prevented the seed germination. Density of the Pythium sp. in the recycled water system at the factory was periodically measured using a selective medium, corn meal agar with Pimaricin 10 mg, Rifampicin 10 mg, Ampicillin 100 mg per 1 liter in order to check the contamination of recycled water. After fitering step using 5 and 1 ml in the recycled system was applied and it was effectively controlled Pythium rot. The daily yield of sprout was stable and the occurrenceof Pythium in the recycled water was much less after filtering. The fungal isolates were identified as Pythium deliense Meurs based on various mycological characteristics on corn meal agar and sucrose-asparagine bentgrass leaf culture medium. P. deliens oogonia were spherical, smooth, 19-23 urn in diameter, and their stalk bending toward antheridia. Antheridia were straw hat-shaped, curred club-shaped, therminal or intercalary, monoclinous, occasionally diclinous, 12∼15 ${\times}$ 8∼11 um, 1(∼2) per oogonium.

  • PDF

A Study on the ICCP Control and Monitoring System for Ship (선박용 ICCP 제어 감시 시스템에 관한 연구)

  • 이지영;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.667-674
    • /
    • 2004
  • This thesis is about the Impressed Current Cathodic Protection (ICCP) control and monitoring system. which brings protection against the corrosion of the ship's hull in the sea environments. The ICCP system is composed of a power supply. anode. reference electrode and controller. AC sources from the ship's generator are converted to DC sources in terms of power supply, and a protection current is sent to ship's hull though anode. The controller fully senses whether or not the detected potential is within a range of protection of ship's hull and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode. The monitoring system with RS 232/485 communication is also studied in order to check the normal state of the system at a long period. because an operator does not always watch over this system and thus the system cannot operate well because of his or her negligent management. Since the vessel always navigates in the sea. an characteristics experiment of the ICCP system is conducted by introducing various corrosive environmental factors such as velocity, resistivity, dissolved oxygen, PH, temperature and contamination degree. These results must be referred to when the ICCP system is set up. In short. the ICCP is a multi-system for use on ships and on land structures because it includes a safety device. It is suggested that this system can accomodate a ship's automation and will be very useful.

Epidemiological Investigation of Onychomycosis and Tinea Pedis in Children (소아의 손·발톱 및 족부백선증에 관한 역학적 조사)

  • Bang, Young-Jun;Kim, Ssang-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.91-95
    • /
    • 2007
  • The number of children patients with tinea pedis and onychomycosis diagnosed on clinical findings and culture at the Catholic Dermatological Clinic in Daegu City were 144,446 for 2 years from January 2005 to December 2006. 120 children were suspected of having clinical onychomycosis or tinea pedis. KOH smears and cultures on the Potato corn meal dextrose agars (PDCA) were done for the suspected toe webs, nails and uninvolved neighbor toe webs. Socks were dusted and cultured to check contamination of clothes. Family infections were checked by questionnaire. The incidence was 92 (0.06%) out of 144,446 outpatients in tinea pedis, 28 (0.02%) in onychomycosis. Trichophyton(T.) rubrums were isolated from all of the 7 cases of onychomycosis. T. mentagrophytes was isolated from 5 cases of the tinea pedis patients and T. rubrum was isolated from 50 (92.5%) cases of the tinea pedis. The right side was predominant for onychomycosis of both toe nails (23 of 25) and finger nails (3 of 3). No fungal elements were detected from normal looking neighbor toe webs by KOH examinations. However, culture on PDCA agars showed T. rubrum isolates from 3 toe webs. 7 showed positive cultures from the socks. From the questionnaire, 94 had family infections.

  • PDF

A Study on Expiration Date on Ethylene Oxide Gas Sterilization Products - Related to Storage Environment - (Ethylene Oxide 가스 멸균물품의 유효기간에 관한 연구 - 보관환경을 중심으로 -)

  • Son, Jeong Sook;Yu, Il Kyong
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.2
    • /
    • pp.141-150
    • /
    • 2014
  • Purpose: This was a study on the expiration date of Ethylene Oxide (EO) gas sterilization and effects of the environmental factors of temperature, humidity and type of cabinet in sterile goods storage area on the expiration date. Methods: Sterile goods storage areas from 13 departments in one hospital were selected and 455 EO gas sterilization samples were prepared and kept in those areas over the 14 months of the study. Each sample was tested with a microbiological culture in the laboratory every week. If the result was positive, the sample was regarded as contaminated. The researcher visited once a month to check the temperature, humidity and type of cabinet. Results: With the exception of 1 sample which was positive at 56th week. 454 samples were confirmed as negative. The environment of the samples storage area was measured monthly. The annual average temperature was $24.2{\pm}1.6^{\circ}C$, and the mean relative humidity $34.7{\pm}15.2%$. The types of cabinet were 7 open and 6 closed. Conclusion: The results of the microbiological culture at 13 months showed that none of the samples were contaminated. Therefore the hospital's existing Expiration Date can be extended from 6 months to 13~14 months.

Study on operating software for monitoring device network in sewage disposal facility (오수처리시설의 가동상태 확인 기기 네트웤의 운영 소프트워어에 관한 연구)

  • 박승환;김창복;김성선
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • In field of environments the monitoring devices for sewage disposal facilities developed to overcome a problem of the water contamination according to industrializaion and urbanization. This paper presents the operating software for monitoring device network which operator in remote station is able to check and see the operating states of the sewage disposal facilities installed in local stations. The software is executed by the hardware base developed by this study and composed of the Program modules for database, data transmission and operating state analysis. As the result of the proposed software system, it is confirmed that we are able to make improvements of the effectiveness of the operating management for environment equipments.

  • PDF

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

Effects of Flushing in Dental Unit Waterlines on the Bacterial Contamination Level (치과용 유니트 수관 물 빼기(Flushing)가 세균 오염도 감소에 미치는 영향)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.659-665
    • /
    • 2015
  • A wide variety of methods have been used to control Dental Unit Waterline (DUWL) contamination. Among the methods, flushing is mainly used because it is simple and easy to use. Generally, flushing of DUWL for 20 or 30 sec before using high speed handpieces or scalers is recommended. However, the appropriateness of flushing time was not investigated thoroughly. The purpose of this study was to check the effective time of flushing for decreasing bacterial contamination. Seven dental unit chairs were randomly selected in student clinical simulation laboratory for this experiment. DUWLs were continuously flushed and water samples were collected at an interval of 30 seconds for 15 minutes. From five dental unit chairs, water samples were collected every 10 seconds for 1 minute. Bacterial levels in water samples were examined by the culture method on R2A plates. After 10 second flushing of DUWLs, the number of bacteria significantly reduced and decreased continuously up to 40 seconds. However, even after the water was flushed for 15 minutes, the bacterial contamination level was not reduced below recommended bacteria level, 200 CFU/ml. In addition to flushing, the periodic chemical disinfection is required to control the DUWL water to the recommended level.