• Title/Summary/Keyword: Contamination

Search Result 5,488, Processing Time 0.033 seconds

On Lead Contamination of Roadside Trees in Jinju City (진주시 가로수의 연(Pb) 오염에 관하여)

  • 성민웅
    • Journal of Plant Biology
    • /
    • v.19 no.4
    • /
    • pp.107-110
    • /
    • 1976
  • This study was carried out to investigate lead contamination in the leaves of roadside trees and the cause of yellow-brown symptom of leaves in Jinju and Daegu city. After the leaves were collected and dried in 105$^{\circ}C$ drying oven from September to October in 1974, the samples were used for analysis of the lead contents in 1976. The roadside trees in the two cities were mostly the four kinds of Ginkgo biloba L., Thuja orientalis L., Platanus orientalis L. var. acerifolia AIT. and Prunus pseudo-cerasus $LINDL{\times}Prunus$ subhirtella MIQ. The lead contents in the leaves of roadside trees in Daegu city was higher than that of Jinju city. The lead contamination of the evergreen trees of roadside was higher than that of the deciduous trees. In Jinju city the site of the highest contents of lead in the leaves was revealed with Jinju station(0.73ppm), the next site was revealed with the road(0.16ppm) between Namgang bridge and Jinju middle school, and the lowest site was generally beside the roads of suburbs (0.07ppm). Because of the low contents of lead in the leaves, it was found that the yellow-brown symptoms of leaves were not caused by the lead toxicity.

  • PDF

Effects of Contact Conditions on the Connector Electrical Resistance of Direct Current Circuits

  • Kim, Young-Tae;Sung, In-Ha;Kim, Jin-San;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.5-10
    • /
    • 2004
  • Electric contacts serve the purpose of transmitting electric signals across two conducting components. In this paper, the effects of contact conditions such as surface roughness, oxidation, and contamination were investigated with respect to electrical resistance variation of a connector in a direct current circuit. Such change in the electrical resistance is particularly important for low power circuits. The experimental results showed that compared with the effects of contact surface scratch or oxidation, the effect of contamination on the resistance variation was the most significant. In order to minimize failure due to electrical resistance change at the contact region, proper sealing to prevent contamination from entering the interface is needed.

A Study Lighting Design Using Polymer Concrete (폴리머 콘크리트를 이용한 조명등 디자인에 관한 연구)

  • 한기웅
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.25-29
    • /
    • 2000
  • Nowadays, natural resource are running out and the level of the environment contamination is getting serious. To solve these problems, each country and institute tend to need many-sided researchs and developments. At this point, especially, there are many coal-mines in Jung-sun and Tae-back where are located in Kangwon province. By the way the abandoned mines cause not only local economy collapse but also environment contamination by submergence of stony mountains. The counterplan is positively inquired further examination by the government. Consequently, we hope that the recycle of polymer concrete can reduce the environment contamination, suggest the new direction of Green Design and can be switched over high added value goods. In conclusion, the recycle of polymer concrete will be valuable.

  • PDF

Measurements of Particles Size Distribution and Average Particle Charge in Operating a Bard Disk Drive (하드디스크 드라이브 동작 시 발생하는 입자 크기분포와 입자당 평균 대전량 측정)

  • Lee Jaeho;Park Dongho;Lee Dae-Young;Yoon Ki-Young;Hwang Jungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.795-804
    • /
    • 2005
  • As the flying height of a slider in a hard disk drive decreases, the slider and disk are more likely to come in contact and generate contamination particles. Since particle contamination can cause serious problems including thermal asperity, it must be prevented to increase storage capacity. When particles are generated in a HDD, particles can be charged and have a few number of elementary charges. In this paper, the size distribution of particles and electrical current due to particle according to the disk rotational speed were measured. Also, the average number of elementary charges was calculated from experimental data. SEM images of particles were obtained by using a particle sampler designed in our laboratory.

Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor (기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석)

  • Lee, Won-Yeong;Shim, Kyu-Il;Han, Sang-Ok;Park, Gang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

Environmental Geochemical characteristics of urban runoff and sediments from gully pot along the main roads in urban area: Heavy metals and VOCs contamination (대도시 지표수와 퇴적물의 환경지구화학적 특성: 중금속 및 VOCs 오염)

  • 이평구;박성원;전치완;신성천
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.129-135
    • /
    • 2000
  • Four types of land use were selected for sampling and study with different characteristics of heavy metal contamination during the period from August 1998 to June 2000. A series of studies have been carried out concerning the physicochemical characteristics of the sediments settling down in a gully pot to evaluate the contamination of Pb, Zn, Cd, Co, Cr and Cu. An examination of six elements indicated that Zn, Cu and Pb were the heavy metals severely impacted by anthropogenic input in Seoul. An assessment of 60 volatile organic compounds (VOCs) in urban runoff and ground water was conducted based on samples collected from 31 sites and 12 wells, respectively, in Seoul City. The higher levels of alkyl benzenes in urban runoff indicated that Seoul areas were mainly contaminated through traffic sources.

  • PDF

Demonstration of Helminth Eggs and Larvae in the Soil of the Public Places in Kwangju Area (광주지역(光州地域) 놀이터 흙에서의 기생충란(寄生蟲卵) 및 유충(幼蟲)의 검출(檢出))

  • Lee, Jae-Il;Lee, Chung-Gil;Kim, Oh-Nam
    • Korean Journal of Veterinary Research
    • /
    • v.22 no.2
    • /
    • pp.253-258
    • /
    • 1982
  • The frequent finding of soil contamination by dogs' feces are remarkable, and such soil contamination may be public health problem. Of 608 samples, 30(4.9%) were positive for nematode ova. Ten paint 3% of sail samples from parks and 7.9% from footpaths were found to contain nematode eggs. Of the helminth eggs detected, eggs of Toxocara spp. were the most commonly encountered, and mostly from the soil of footpaths. No eggs were recovered from the soil of school yards; the level of soil contamination was low in public play areas. Egg recovery rate of the soil to dogs' feces collected from footpaths was approximately 1:5. And the larvae demonstrated from the soil in the present study were nematode larvae, mainly recovered from parks.

  • PDF

Insulation coordination of 765 KV double circuit transmission line (765 KV 2 회선(回線) 송전선(送電線) 절연협조(絶緣協助))

  • Kim, Jeong-Boo;Min, Suk-Won;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.774-777
    • /
    • 1988
  • This paper covers the insulation coordination of 765 KV transmission line in Korea Electric Power Corporation. The design for the lightning, switching surge, and contamination was conducted to increase the reliability of 765 KV line. The authors have used the result of a limited Westinghouse ANACOM swiching surge study of the Korea Electric Corporation's 765 KV Expansion plan. The study investigated the switching surge overvoltage distribution and maximum switching overvoltage when relosing 765 KV lines. They used the technical data of the suspension insulator for the contamination design, which was available from a foreign insulator manufacture. From this paper, the authors find out that the contamination design dominates to determine the number of insulator and the SOV design dominates the air clearance in the tower. Afterwards the authors will confirm this design by Demonstration Test with Korea Electro-technology Research Institute.

  • PDF

Strong Red Photoluminescence from Nano-porous Silicon Formed on Fe-Contaminated Silicon Substrate

  • Kim, Dong-Lyeul;Lee, Dong-Yul;Bae, In-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.5
    • /
    • pp.194-198
    • /
    • 2004
  • The influences of the deep-level concentration of p-type Si substrates on the optical properties of nano-porous silicon (PS) are investigated by deep level transient spectroscopy (DLTS) and photoluminescence (PL). Utilizing a Si substrate with Fe contaminations significantly enhanced the PL intensity of PS. All the PS samples formed on Fe-contaminated silicon substrates had stronger PL yield than that of reference PS without any intentional Fe contamination but the emission peak is not significantly changed. For the PS 1000 sample with Fe contamination of 1,000 ppb, the maximum PL intensity showed about ten times stronger PL than that of the reference PS sample. From PL and DLTS results, the PL efficiency strongly depends on the Fe-related trap concentration in Si substrates.