Influence of Metallic Contamination on Photovoltaic Characteristics of n-type Silicon Solar-cells (중금속 오염이 n형 실리콘 태양전지의 전기적 특성에 미치는 영향에 대한 연구)

  • Kim, Il-Hwan;Park, Jun-Seong;Park, Jea-Gun
    • Current Photovoltaic Research
    • /
    • v.6 no.1
    • /
    • pp.17-20
    • /
    • 2018
  • The dependency of the photovoltaic performance of p-/n-type silicon solar-cells on the metallic contaminant type (Fe, Cu, and Ni) and concentration was investigated. The minority-carrier recombination lifetime was degraded with increasing metallic contaminant concentration, however, the degradation sensitivity of recombination lifetime was lower at n-type than p-type silicon wafer, which means n-type silicon wafer have an immunity to the effect of metallic contamination. This is because heavy metal ions with positive charge have a much larger capture cross section of electron than hole, so that reaction with electrons occurs much more easily. The power conversion efficiency of n-type solar-cells was degraded by 9.73% when metallic impurities were introduced in the silicon bulk, which is lower degradation compared to p-type solar-cells (15.61% of efficiency degradation). Therefore, n-type silicon solar-cells have a potential to achieve high efficiency of the solar-cell in the future with a merit of immunity against metal contamination.

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.

Consumer Hygiene Practices Regarding the Use of Home Refrigerators to Store Meat in the Capital Area of Korea

  • Lee, Jong-Kyung;Kim, Eun-Hae;Lee, Min-A
    • Food Science of Animal Resources
    • /
    • v.33 no.2
    • /
    • pp.149-154
    • /
    • 2013
  • Food hygiene practices must be maintained from farm to table in order to prevent contamination by microorganisms. This study was conducted to investigate consumer hygiene practices related to the refrigerator storage of meat, including a microbial analysis, monitoring of refrigerator temperatures and consumer surveys of female homeowners in the capital area of Korea. Home refrigerator temperatures were maintained above $5^{\circ}C$ in 26 (19.7%) of the 132 houses investigated. The percentage of the refrigerators with a total microbial count over $10^2\;CFU/100\;cm^2$ was 14.4%. No E. coli, Salmonella spp. or Listeria monocytogenes microbes were detected. However, Staphylococcus aureus was detected in 14 houses (10.6%). The only statistically significant difference in hygiene practices between the non-contamination group and contamination group was in the last time of refrigerator cleaning (p<0.01), as determined by the consumer survey. To improve food hygiene when using a refrigerator, raw materials must be packaged, meat should be stored only on a designated shelf, and cooked foods must be contained to prevent cross-contamination. The refrigerator should be cleaned regularly, at least once a month, and refrigerator thermometers should be monitored below $5^{\circ}C$ in order to keep food safe.

The Growth Inhibition of Staplylococcus aureus in Emulsion Type Cosmetics with Antiseptics (방부살균제에 의한 유화형화장품에서의 Staplylococcus aureus의 성장억제)

  • 류미숙;김장규;원성호;김남기
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.22-29
    • /
    • 1992
  • Emulsion-type cometics contain many kinds of carbon and energy source i.e., vegetable oil, mineral oil and carbohydrate etc., those can be used as nutrients and caused contamination by microbials. Thereby we have to keep cosmetics from the possibility of contamination by microbials. From this viewpoint, the purpose of this study is to get the data necessary not only to prevent dermatopathia occurred by microbials but also to sustain the quality. In this experiment, we observed how many Staphylococcus aureus were grown in the prepared cosmetics with or without antiseptics so as to prevent contamination. When the contamination proceed, the stability of phase was disturbed and creaming phenomina was happened with some discoloration and bad smell. About 40 days after, the pH was changed from 7.6 to 6.5 and the refractive index of cosmetic raw materials were changed from 1.4415 to 1.4490(water : oil=70:30). By adding antiseptics Into prepared cosmetics, the number of Staphylococcus aureus with challenge test method were decreased to 7$\times$103 cell/ml. For the antibacterial effect against Staphylococcus aureus, p-hydroxy benzoic acid propyl ester in phosphoric acid buffer solution was the best.

  • PDF

A Study on TRIZ Applied Design for Contamination Preventation System of Solar Battery with Wind Amplifier (바람 증폭 장치를 가진 태양전지 오염방지시스템의 TRIZ(6SC) 응용 설계)

  • Huh, Yong Jeong;Hong, Sung Do;Kim, Jae Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.7-11
    • /
    • 2013
  • This paper presents a study on the design for contamination preventation system of solar battery. The system of contamination preventation has an wind amplifier. Wind amplifier is conceptually designed by using TRIZ. The surface of solar battery is covered with dust during accumulate the energy. The dust cause reduce power of photovoltaic module and efficiency drop of photovoltaic system. Reflect and absorb of incident ray are caused by the dust on surface of solar battery. The solution of this problem has been derived using 6SC(6 steps creativity)TRIZ. The wind amplifier which has structure such as funnel shape. The incident wind in the wide hole is amplified by the gate become narrow. The system of contamination preventation with wind amplifier which mounted on the side of the solar battery surface reduces the reflect and absorb and improve the efficiency of photovoltaic system.

Heavy Metal Concentrations in Soils of the Daegu and Ulsan Area (대구·울산지역의 토양 중금속 오염도 평가)

  • Lee Tae-Gwan
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.605-611
    • /
    • 2005
  • The aim of this study was to analyze the local distribution of the heavy metal concentration in Daegu and Ulsan which were divided into the residual areas, the traffic dense areas and the industrial areas. The Inductively Coupled Plasma(ICP) was used to analyze heavy metals, such as As, Cr, Hg, Zn, Cd, Pb, Cu and minor metals, such as Fe, Si, Mg, Ca, AI, Na, K. The results of this analysis showed that the content of heavy metals which was classified by districts in Daegu and Ulsan was the highest in the industrial areas followed by the traffic dense areas and the residual areas. Compared to the level of heavy metals of national and local soil survey network in 2003, contamination of heavy metals in Daegu was lower than national average. However, the content of Cd, As, Zn in Ulsan was respectively 13.38 times, 472 times and 2.65 times higher than national average contamination. In addition, compared to the soil pollution level of the environmental protection law, contamination of all areas in Daegu was lower. But the content of As at the industrial areas in Ulsan was 10.71 times higher than standard of soil pollution and 4.28 times higher than standard of measures against soil contamination.

Study on the Reduction of Electron Contamination with A Cobalt-60 Gamma Ray (코발트-60 감마선의 전자 오염에 관한 연구)

  • Kim, Tae-Kyu;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.293-297
    • /
    • 1989
  • Electron contamination due to the interaction between radiation beam and material was analyzed for the factors such as source-skin distance (SSD), field size, tray characteristics and position of filter, which can affect the surface dose in Cobalt teletherapy. Surface dose in open beam was more influenced by SSD with increasing field size. Relative surface charge (RSC) increased with the use of tray (solid, circular hole, slotted), compared with open beam, which is thought to be due to increased electron contamination of the tray. To reduce the surface dose, 0.4mm thick Lipowitz metal filter was used. Compared with open beam, RSC decreased by 8.8%, 11.3%, 13.3%, 16.6%, 19.3% and 21.7% for the field size of $5{\times}5$, $10{\times}10$, $15{\times}15$, $20{\times}20$, $25{\times}25$ and $30{\times}30cm^2$, respectively. On the contrary, use of Lipowitz metal filter increased RSC at 60cm or less SSD. Surface dose was effectively reduced with Lpowitz metal filter placed right below solid tray in Cobalt teletherapy.

  • PDF

Contamination Particle and Cracking Behavior of the Anodic Oxidation in Sulfuric Acid Containing Cerium Salt (세륨염을 첨가한 황산법 양극산화피막의 오염입자 및 열크랙 거동)

  • So, Jongho;Yun, Ju-Young;Shin, Jae-Soo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.11-15
    • /
    • 2018
  • The parts of equipment for semiconductor are protected by anodic aluminum oxide film to prevent corrosion. This study investigated contamination particle and cracking behavior of anodic oxidation in sulfuric acid containing cerium salt. The insulating properties of the sample were evaluated by measuring the breakdown voltage. It was confirmed that the breakdown voltage was about 50% higher when the cerium salt was added, and that the breakdown voltage after the heat treatment was 55% and 35% higher at $300^{\circ}C$ and $400^{\circ}C$, respectively. After heating at $300^{\circ}C$ and $400^{\circ}C$, cracks were observed in non cerium and cerium 3mM, and more cracks occur at $400^{\circ}C$ than at $30^{\circ}C$. The amount of contamination particles generated in the plasma is about 45% less than that of non-cerium specimens.

Time Shifted Pilot Signal Transmission With Pilot Hopping To Improve The Uplink Performance of Massive MIMO System For Next Generation Network

  • Ruperee, Amrita;Nema, Shikha
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4390-4407
    • /
    • 2019
  • The paucity of pilot signals in Massive MIMO system is a vital issue. To accommodate substantial number of users, pilot signals are reused. This leads to interference, resulting in pilot contamination and degrades channel estimation at the Base Station (BS). Hence, mitigation of pilot contamination is exigency in Massive MIMO system. The proposed Time Shifted Pilot Signal Transmission with Pilot signal Hopping (TSPTPH), addresses the pilot contamination issue by transmitting pilot signals in non-overlapping time interval with hopping of pilot signals in each transmission slot. Hopping is carried by switching user to new a pilot signal in each transmission slot, resulting in random change of interfering users. This contributes to the change in channel coefficient, which leads to improved channel estimation at the BS and therefore enhances the efficiency of Massive MIMO system. In this system, Uplink Signal Power to Interference plus Noise Power Ratio (SINR) and data-rate are calculated for pilot signal reuse factor 1 and 3, by estimating the channel with Least Square estimation. The proposed system also reduces the uplink Signal power for data transmission of each User Equipment for normalized spectral efficiency with rising number of antennas at the BS and thus improves battery life.

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

  • Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.65-70
    • /
    • 2021
  • Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.