• 제목/요약/키워드: Contaminated air

검색결과 324건 처리시간 0.031초

수평 급기가 레인지 후드 주위의 자연대류에 미치는 영향 (Horizontal Air-Jet Effect on the Natural Convection around a Range-Hood System)

  • 김병국;최형권;용호택;이명호
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.333-340
    • /
    • 2005
  • Horizontal air-jet effect has been utilized in some air conditioning systems in order to control the contaminated air indoor. In the present study, the flow and heat transfer of the contaminated air from a range hood system has been investigated with or without horizontal air-jet effect when the hood fan is on or off. For the present numerical experiment, PAT Flow code has been used. From the present numerical simulations, it has been shown that the air jet of a range hood generates coanda effect confining the contaminated air in a certain region. Furthermore, the qualitative relation between the flow rate of the capture air jet and the distribution pattern of the contamination has been discussed.

Hybrid Pilot System을 이용한 철도 오염토양 복원 (Remediation of Contaminated Railroad Soils using by Hybrid Pilot System)

  • 박덕신
    • 한국철도학회논문집
    • /
    • 제3권3호
    • /
    • pp.101-108
    • /
    • 2000
  • In this study, we tested hybrid pilot system combined with soil vapor extraction and bioventing methods on the contaminated railroad soil. So, we found out the remediability and operating conditions. Air permeability(k) and gas phase(O$_2$/CO$_2$/VOCs) level trend are very important to determine the remediation rate of the contaminated sites. Throughout hybrid pilot test on different conditions, the range of air permeability(k) was 1985∼1194 darcy. The tests results in hybrid system was appropriate on this test sites, and the suitable injection air flow rate was 3.5㎥/hr. So, we suggested a basic data for the remediation and management of contaminated railroad soil.

  • PDF

원유로 오염된 갯벌 지역의 자연정화 기능 향상 기술의 개발 (Enhanced Natural Purification of Crude Oil Contaminated Tidal Flat)

  • 김영아;성기준
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권5호
    • /
    • pp.24-30
    • /
    • 2011
  • Tidal flats which are ecologically sensitive, are hard to remediate once they are contaminated by oil spill accidents. Traditional oil remediation measures focus on removal efficiency, and their improper implementation can adversely affect crude oil contaminated coastal areas and greatly disrupt the structure and functions of crude oil contaminated tidal flats. In this study, the oil degradation due to the implementation of remediation measures naturally enhanced using air and natural oil sorbents was evaluated in the lower strata of tidal flats. The effects of air and natural oil sorbents on oil degradation for two concentration levels (< 500 ppm and > 500 ppm) were tested at artificially contaminated tidal flats. Fifty days after these treatments, the natural oil sorbent treatment showed the lowest total petroleum hydrocarbon (TPH) concentration ($4.46{\pm}1.47%$) at the low concentration level, whereas both air and natural oil sorbent treatments showed high degradation efficiencies at the high concentration level ($29.30{\pm}4.39%$). Although the phosphatase activity decreased for all treatments, there was no significant difference between the decreases for the different treatments; on the other hand, B-glucosidase activities were high for both air and natural oil sorbent treatments. Although degradation efficiencies decreased as the concentration increased, the air provision and natural oil sorbent treatment could be an effective ecological restoration measure for oil contaminated tidal flats while minimizing the environmental impact of the remediation efforts.

유류오염토양 복원을 위한 설계인자 선정에 관한 연구

  • 조장환;전권호;서창일;박정구
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.293-296
    • /
    • 2004
  • The objective of this study was to decide the designing factor for remediaton of the contaminated site. The soil and ground-water samples were analyzed and hydro- geological characteristics was assayed for the survey of pollution level. Also air-permeability test and MPN(most probable number) test were conducted for selecting the designing factor. The contaminants were mainly found in north-west part of the site and were expected to move toward the south. Ex-situ technology was expected more useful than in-situ one with the results of air-permeability test saying that air permeability was relatively low. Additional microbes were expected for remediation efficiency because residual microbes were loosely populated. The choosing of the designing factor was requisite for remediation of contaminated site.

  • PDF

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

공동주택에서의 실외 급.배기구 위치에 따른 환기효율 향상 연구 (A study on the Improvement of Ventilation Performance in Apartment House According to the Location of Exterior Air-Vents)

  • 박진철;유형규;차진영
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.71-79
    • /
    • 2005
  • In this study, the ventilation performance of mechanical ventilation system in apartment House was analyzed through model test according to characteristics of air-vent. Then adequate interval of air-vent was suggested using computer simulation which will create comfort environment through improvement of ventilation performance in apartment house. The result of experiment with separation plate to prevent mixture of contaminated exhaust air with fresh supply air, the ventilation efficiency improved about 10%. The result of simulation with horizontal location of exterior air-vent, contaminated exhaust air is mixed regardless of interval variation. Consequently, mixture of the exhaust air can be prevented through locating the supply air vent on the top side and exhaust air vent on the lower side.

과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법(Air-sparging)을 연계한 디젤 오염 토양/지하수 동시 정화 실내 실험 연구 (Study on the Combination of In-situ Chemical Oxidation Method by using Hydrogen Peroxide with the Air-sparging Method for Diesel Contaminated Soil and Groundwater)

  • 김남호;김인수;최애정;이민희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권6호
    • /
    • pp.8-17
    • /
    • 2006
  • 현장비원위치(Ex-situ) 공법 적용이 불가능한 부지에서, 디젤로 오염된 오염 토양과 지하수를 동시에 복원하기 위하여 과산화수소를 이용한 현장원위치 화학적 산화법(chemical oxidation)과 공기분사법(air-sparging)을 연계한 복합 복원 공정의 정화 효율 규명을 위한 실내 실험을 실시하였다. TPH 농도가 2,401 mg/kg(A 토양)과 9,551 mg/kg(B 토양)인 두 종류의 현장 오염 토양을 대상으로 과산화수소용액을 이용한 화학적 산화법의 디젤 제거 효율 규명을 위한 배치(회분식) 실험 결과, 과산화수소 50% 용액에 의해 토양 초기 TPH 농도의 18%와 15%까지 감소하였다. 과산화수소 용액 20%를 이용한 칼럼 세정 실험 결과, 세정에 의해서 A 토양과 B 토양의 경우 각각 초기 TPH 양의 78%와 72%가 제거되었다. 칼럼 실험에서 과산화수소의 산화반응에 의해 완전 분해되어 무기가스상(주로 $CO_2$$H_2O$)으로 제거된 양까지 고려한다면, 과산화수소용액이 오염 토양과 접촉하면서 충분한 산화과정을 거쳐 대부분의 유류가 토양으로부터 제거되었음을 알 수 있었다. 공기분사법을 이용한 디젤 오염 지하수 정화 실험의 경우, TPH 농도가 820 mg/L인 고농도의 인공 지하수 경우에도 공기분사 72시간 이내에 폐수배출허용기준인 5 mg/L 보다 낮아져, 디젤 제거 효율이 매우 높은 것으로 나타났다. 다만, 오염 토양 내 다량의 디젤 자유상이 존재하는 경우 토양으로부터 지하수로의 지속적인 자유상 디젤의 질량 이동에 의하여, 공기분사법의 지하수 정화 효율은 매우 낮았다. 마지막으로, 과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법을 연계한 복합 공정의 디젤 정화 효율을 규명하는 박스 실험을 실시하였다. 토양 내 자유상 디젤을 먼저 제거하기 위해 과산화수소 용액을 이용한 토양세정법을 실시한 후, 토양 내 TPH가 제거 되는 정도에 따라 후차적으로 공기분사법을 적용함으로써 토양 및 지하수로부터 디젤을 효과적으로 제거할 수 있었다. 20% 과산화수소 용액의 23 L 세정과 2,160 L의 공기분사에 의해 토양의 TPH 농도는 9,551 mg/kg에서 390 mg/kg으로 낮아졌으며, 오염 지하수의 TPH 농도도 5 mg/L 이하로 낮출 수 있었다. 본 실험들에서 얻어진 결과를 바탕으로 실제 현장에서 대단위 공정을 운영하는데 필요한 복원 공정의 최적 조건들을 도출해 낼 수 있으리라 판단되며, 유류로 오염된 토양 뿐 아니라 오염 지하수까지 동시에 정화할 수 있는 복합 공정 개발을 위한 중요한 기술 자료로 이용될 수 있을 것으로 판단된다.

Lab-Scale Biosparging Study to Remediate Diesel-Contaminated Soil and Groundwater : the effect of air injection rate and pattern

  • 조수형;이시진;권순열;장순웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.462-466
    • /
    • 2003
  • This study was conducted to examine the potential of biosparging process in removing diesel contaminated soil and groundwater. The experiment was carried out lab-scale biosparging reactor and the biodegradation rate of diesel was evaluated as function of air injection rate and pattern. When renter was operated as air injection rate of 1000$m\ell$/min and pulsed air injection(15min pulse, 15min downtime), DO concentration in the renter was higher than another operating condition. The evidence for biodegradation of diesel was the $O_2$ utilization and $CO_2$ product following the cessation of sparging. Especially, air injection rate of 2000$m\ell$/min and pulsed air injection(15min pulse, 15min downtime) enhanced the diesel biodegradation during the operating. After 120day, the biodegradation rate of diesel was decreased as the lack of carbon source.

  • PDF

신선초 분말에 오염시킨 미생물에 대한 감마선과 오존의 살균효과 (Sterilization Effects of $\gamma-ray$ and Ozone on Microoganisms Contaminated in Angelica keiskei Powde)

  • 권오진;박순연;김광훈;이현자;변명우
    • 한국식품위생안전성학회지
    • /
    • 제11권3호
    • /
    • pp.221-225
    • /
    • 1996
  • For the purpose of improving hygienic quality of health-foods, sterilization effects of ${\gamma}$-ray and ozone on microoganisms associated with food cultured in the media and contaminated in Angelica keiskei powder were investigated. Ozone was immersed in water and sprayed in air, on the concentration of 3 mg liter-1 at an air flow rate of 5 liter min-3. Test strains cultured in the media completely inhibited by ${\gamma}$-ray at irradiation doses of 0.25~2 kGy. In the case of ozone, test bacteria inactivated after treatment of 10~20 minutes, but test mold, Aspergillus flavus was not effective. Strains contaminated in Angelica keiskei powder completely inhibited by ${\gamma}$-ray at irradiation doses of 2.5~7.5 kGy. However, when the powder was sprayed with ozonized air for 10hours, Bacillus subtilis and Staphylococcus aureus among five strains were eliminated.

  • PDF

Aeration Factor Used To Design The Container Type of Biopile Systems for Small-Scale Petroleum-Contaminated Soil Projects

  • Jung, Hyun-Gyu
    • 한국토양비료학회지
    • /
    • 제44권2호
    • /
    • pp.316-319
    • /
    • 2011
  • Biopiles which offer the potential for cost-effective treatment of contaminated soils are above-ground, engineered systems that use oxygen to stimulate the growth and reproduction of aerobic bacteria for degradation of the petroleum constituents adsorbed to soil in excavated soils. This technology involves heaping contaminated soils into piles and stimulating aerobic microbial activity within the soils through the aeration and/or addition of minerals, nutrients, and moisture. Inside the biopile, microbially mediated reactions by blowing or extracting air through the pipes can enhance degradation of the organic contaminants. The influence of a aeration system on the biopile performance was investigated. Air pressure made to compare the efficiency of suction in the pipes showed that there were slightly significant difference between the two piles in the total amount of TPH biodegradation. The normalised degradation rate was, however, considerably higher in the aeration system than in the normal system without aeration, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile.