• Title/Summary/Keyword: Contaminated Process

Search Result 692, Processing Time 0.023 seconds

Analysis of Influence Factors for Remediation of Contaminated Soils Using Prefabricated Vertical Drains (연직배수재를 이용한 오염지반 복원의 영향인자 분석)

  • Park, Jeongjun;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.2
    • /
    • pp.39-46
    • /
    • 2008
  • Due to the growth in industrialization, potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. There are a number of approaches to in-situ remediation that are used in contaminated sites for removing contaminants. These include soil flushing, dual phase extraction, and soil vapor extraction. Among these techniques, soil flushing was the focus of the investigation in this paper. Incorporated technique with PVDs has been used for dewatering from fine-grained soils for the purpose of ground improvement by means of prefabricated vertical drain systems. The laboratory model tests were performed by using the flushing tracer solutions for silty soils and recorded the tracer concentration changes with the elapsed time and flow rates. The modeling was intended to predict the effectiveness and time dependence of the remediation process. Modeling has been performed on the extraction, considering tracer concentration and laboratory model test characteristics. The computer model used herein are SEEP/W and CTRAN/W, this 2-D finite element program allows for modeling to determine hydraulic head and pore water pressure distribution, efficiency of remediation for the subsurface environment. It is concluded that the coefficient of permeability of contaminated soil is related with vertical velocity and extracted flow rate. The vertical velocity and extracted flow rate have an effect on dispersivity and finally are played an important role in-situ soil remediation.

  • PDF

A Study of Heavy Metal-Contaminated Soil Remediation with a EDTA and Boric acid Composite(II): Cd and Cr (EDTA와 붕산 혼합용출제를 이용한 중금속으로 오염된 토양의 처리에 관한 연구(II): 카드뮴 및 크롬)

  • Lee Jong-Yeol;Kim Yong-Soo;Kwon Young-Ho;Kong Sung-Ho;Park Shin-Young;Lee Chang-Hwan;Sung Hae-Ryun
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.8-14
    • /
    • 2004
  • To investigate the optimal operation factors in appling Soil Flushing Process, which use EDTA and boric acid composite as a flushing reagent, to the Cd(cadmium) and Cr(chromium) contaminated sites, Cd and Cr emediation rate was investigated at various experimental conditions; as EDTA concentration was increased from 0.001M to 0.1M, Cd remediation rate was increased from $73.2\%\;to\;98.5\%$; as boric acid concentration was increased from 0.001M to 0.1M, Cr remediation rate was increased from $59.2\%\;to\;99.0\%$. In the experiments using 0.005M of EDTA and 0.005M of boric acid composite as a flushing reagent at different pH regimes, Cd remediation rate was decreased from $92.4\%\;to;80.9\%$ as the pH was increased from 3 to 7. But Cr remediation rate was more effective ($70.4\%$) at pH 5 compared to the other pHs. Furthermore, at pH 5, Cd and Cr remediation rate was investigated at different molecular ratio of [EDTA]/[Boric aicd]; the optimized [EDTA]/[Boric acid] ratio was 0.01M/0.1M for Cd contaminated site and, as the concentration of boric acid was increased over 0.1M, Cr remediation rate was also increased. So the similar results were shown in the experiments using real contaminated soils which were sampled from a mining and a industrial area.

Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process (산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향)

  • Kim, Jung Hwan;Na, So Jeong;Park, Joo Yang;Byun, Young Deog
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

산업단지내 독성유기화합물 및 중금속으로 오염된 토양의 정화복원기술 상용화 연구

  • 김수곤;손규동;박지연;최희철;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.31-34
    • /
    • 2004
  • Feasibility of electrokinetic(EK)-Fenton process and Ozone chemical oxidation were investigated for tile removal of organic contaminants and heavy metals from the contaminated soil. In EK-Fenton process, accumulated electroosmotic flow(EOF) was 80 L for 26 days. Removal efficiency of TPH, As, and Ni were 61%, 36%, and 47%, respectively. The concentration of As was high near the anode due to the transport of anionic As toward the anode, while the concentration of Ni was high near the cathode by the movement of cationic Ni to the cathode. Field scale application of in-situ ozonation was carried out for removal of TPH in 3-D test cell (3 m$\times$2 m$\times$2 m). After 25 days of ozone injection, more than 80% of removal rate was observed through the test cell.

  • PDF

Kinetics of 1,4-Dioxane Oxidation during $O_3-H_2O_2$ Treatment

  • Suh, Jung-Ho;Lee, Hak-Sung;Park, Yong-Hee;Lee, Yong-Hee;Shu, Myung-Gyo
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.351-354
    • /
    • 2005
  • The removal of 1,4-dioxane and the biodegradability enhancement of dioxane contaminated water was investigated using $O_3-H_2O_2$ based advanced oxidation process. Experiments were conducted using a bubble column reactor under different dioxane and peroxide concentrations as well as PH. The $O_3-H_2O_2$ process effectively converted dioxane to more biodegradable intermediates and increased the biodegradability and average oxidation state of dioxane in the solution.

  • PDF

Neutral Deinking of Old Newspapers Contaminated with Flexo Ink - Evaluation of the deinking efficiency of alcohol type neutral deinking agents - (플렉소 잉크가 포함된 신문고지의 중성 탈묵 - 알코올계 계면활성제의 효과 평가 -)

  • Ryu, Hoon;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.31-40
    • /
    • 2006
  • Presence of old newspapers printed with waterbased flexographic inks leads to a significant loss of brightness of the deinked pulp by flotation process. It has been shown that neutral or acidic flotation deinking has many advantages in recycling of flexo printed newsprints. A comparative experimental study was performed to evaluate the deinking efficiency of three alcohol type deinking agents in flotation deinking of flexo printed newspapers. Zeta potential of neutral deinked pulp was less negative than alkaline deinked pulp. Also neutral deinking was advantages in reducing turbidity, COD, and cationic de-mands of deinking process water.

The Study of Cd and Pb Characteristics on Electrokinetic Remediation of Mine Deposit (Electrokinetic 기법에 의한 광산퇴적토내 Cd과 Pb의 제거 특성에 관한 연구)

  • 윤삼석;신현무;이창언
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.61-64
    • /
    • 2001
  • In the remediation of contaminated soil by electrokinetic process, transport characteristics of contaminants are major factors. Pb is highly fixed to entire soil and not moved readily. High concentration of Cd was analyzed in the cathodic section but anodic section's concentration was lower than initial concentration. Although the Cd had high treatment effect, 50% of total mass was concentrated in cathodic section and was not flowed out readily. Most of transported Cd may be adsorbed in the cathodic side soil due to increased pH at adjacent to catholyte.

  • PDF

Control Charts Based on Self-critical Estimation Process

  • Won, Hyung-Gyoo
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.100-115
    • /
    • 1997
  • Shewhart control chart is a basic technique to monitor the state of a process. We observe samples of size four or five and plot some statistic(e.g., mean or range) of each sample on the chart. When setting up the chart, we need to obtain u, pp.r and lower control limits. It is common practice that those limits are calculated from the preliminary 20-40 samples presumed to be homogeneous. However, it may ha, pp.n in practice that the samples are contaminated by outlying observations caused by various reasons. The presence of outlying observations make the control limits wider and hence decrease the sensitivity of the charts. In this paper, we introduce robust control charts with tighter control limits when outlying observations are present in the preliminary samples. Examples will be given via simulation study.

  • PDF

화학적 특성이 다른 두 토양에서 EK-Fenton 공정 적용 시에 $H_2O_2$의 거동과 phenanthrene의 처리특성

  • 김정환;이군택;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.128-131
    • /
    • 2003
  • To clarify the effect of soil property on the EK-Fenton remediation of the soil contaminated with phenanthrene, this research had been conducted. In the experiments using EPK kaolinite, the $H_2O$$_2$ stability and effect of phenanthrene treatment improved more than that in the experiments using Hadong clayey soil. The results signify that Fe oxide content and acid buffer capacity significantly affected the fate of $H_2O$$_2$ and phenanthrene during the EK-Fenton process.

  • PDF