• Title/Summary/Keyword: Containment system

Search Result 382, Processing Time 0.021 seconds

Evaluation of the Fatigue Strength and the Mechanical Properties for Cargo Containment System in LNG Ship (LNG선박용 내조시스템 소재의 기계적 특성 및 피로강도 평가)

  • Shim, Hee-Jin;Kim, Min-Tea;Yoon, In-Su;Kim, Yung-Kyun;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1-6
    • /
    • 2007
  • The membrane type LNG(Liquefied Natural Gas) cargo containment system is a special design structure for the large deformation behavior at LNG temperature$(-162^{\circ}C)$. The design of membrane is required great confidence so that membrane can plat role in the tightness of flammable fluid storing. LNG cargo containment is loaded and unloaded LNG between twice and five times in a week. During this process, the membrane has large deformation behavior due to the variation of temperature and pressure to the self weight. In this study, the evaluation of the fatigue strength of membrane is very important to determine the design life of LNG storage tank and to evaluate the mechanical properties at the LNG temperature. Also, in the view point of large deformation, the evaluation method is applied conservatively $\epsilon-N_f$ curve of SUS 304L.

  • PDF

Effects of No Stiffness Inside Unbonded Tendon Ducts on the Behavior of Prestressed Concrete Containment Vessels

  • Noh, Sang-Hoon;Kwak, Hyo-Gyong;Jung, Raeyoung
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.805-819
    • /
    • 2016
  • The numerical simulation methodologies to evaluate the structural behaviors of prestressed concrete containment vessels (PCCVs) have been substantially developed in recent decades. However, there remain several issues to be investigated more closely to narrow the gap between test results and numerical simulations. As one of those issues, the effects of no stiffness inside unbonded tendon ducts on the behavior of PCCVs are investigated in this study. Duct holes for prestressing cables' passing are provided inside the containment wall and dome in one to three directions for general PCCVs. The specific stress distribution along the periphery of the prestressing duct hole and the loss of stiffness inside the hole, especially in an unbonded tendon system, are usually neglected in the analysis of PCCVs with the assumption that the duct hole is filled with concrete. However, duct holes are not small enough to be neglected. In this study, the effects of no stiffness inside the unbonded tendon system on the behaviors of PCCVs are evaluated using both analytical and numerical approaches. From the results, the effects of no stiffness in unbonded tendons need to be considered in numerical simulations for PCCVs, especially under internal pressure loading.

Assessment of the Internal Pressure Fragility of the CANDU Type Containment Buildings using Nonlinear Finite Element Analysis (비선형 유한요소해석을 이용한 CANDU형 격납건물의 내압취약도 평가)

  • Hahm, Dae-Gi;Choi, In-Kil;Lee, Hong-Pyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.445-452
    • /
    • 2010
  • In this paper an assessment of the internal pressure fragility of the CANDU type containment buildings is performed. The uncertainties of the performance of the containment buildings, material properties and tendon characteristics are referred from the in-service reports of Wolsung Unit 1. The containment buildings are modeled as a three-dimensional finite elements with considering the major opening and penetrations. A new method to evaluate the probabilistic fragility of the massive structural system is developed. The fragility curves of the target containment building are presented with repect to the failure modes and reliability levels. The center of wall is reveled as the most weak structural component of the containment building in the sense of the rupture and catastrophic rupture failure modes.

Seismic performance evaluation of fiber-reinforced prestressed concrete containments subject to earthquake ground motions

  • Xiaolan Pan;Ye Sun;Zhi Zheng;Yuchen Zhai;Lianpeng Zhang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1638-1653
    • /
    • 2024
  • Given the unpredictability of the occurrence of the earthquake and other potential disasters into consideration, the nuclear power plant may be confronted with beyond design-basis earthquake load in the future. The containment structure may be severely damaged under such severe earthquake loading, increasing the risk of containment concrete cracking and potential radioactive materials leaking. Moreover, initial damage caused by the earthquake may significantly alter the pressure performance of the containment under follow-up internal pressure. To compromise the dangers of beyond design-basis earthquake to the containment, an alternative of replacing the conventional concrete with fiber-reinforced concrete (FRC) to upgrade the seismic resistance capacity of the containment is attempted and thoroughly researched. In this study, the influence of various fiber types such as rigid fiber and mixed fiber is regarded to constitute fiber-reinforced PCCVs. The physical properties of traditional and fiber-reinforced PCCVs under earthquake ground motions are scientifically compared and identified by using traditional and proposed evaluation indices. The results indicate that both the traditional evaluation index (i.e. top displacement, stress, strain) and the proposed damage index are greatly reduced by the practice of fiber strengthening under earthquake ground motions.

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

Placement of Colloidal Silica gel for the construction of a subsurface containment system

  • Kim, Meejeong;Park, Joo-Yang
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.66-69
    • /
    • 2001
  • A subsurface containment system which is constructed by pumping a gelling liquid (Colloidal Silica) into the unsaturated medium is investigated by developing a mathematical model and conducting numerical simulations. The proposed model is verified by comparing experimentally and numerically determined hydraulic conductivities of gel-treated soil columns at different Colloidal Silica (CS) injection volumes. The numerical experiments indicate that an impermeable gel layer is formed within the time period twice the gel-point. At the Same normalized time, the CS solutions with lower NaCl concentrations result ill further migration and poor Performance in plugging the pore space.

  • PDF

A Seismic Stability Design by the KEPIC Code of Main Pipe in Reactor Containment Building of a Nuclear Power Plant (원자력 발전소 RCB 내 중요배관의 KEPIC 코드에 의한 내진 안전성 설계)

  • Yi, Hyeong-Bok;Lee, Jin-Kyu;Kang, Tae-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.233-238
    • /
    • 2011
  • In piping design of nuclear power plant facilities, the load stress according to self-weight is important for design values in test run(shutdown and starting). But sometimes it needs more studies, such as seismic analysis of an earthquake of power plant area and fatigue life and stress of thermal expansion and anchor displacement in operating run. In this paper, seismic evaluations were performed to nuclear piping system of Shin-Kori NO. 3&4 being built in Pusan lately. Results of seismic analysis are evaluated on basis of KEPIC MN code. The structural integrity on RCB piping system was proved.

A Preliminary Study for the Implementation of General Accident Management Strategies

  • Yang, Soo-Hyung;Kim, Soo-Hyung;Jeong, Young-Hoon;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.695-700
    • /
    • 1997
  • To enhance the safety of nuclear power plants, implementation of accident management has been suggested as one of most important programs. Specially, accident management strategies are suggested as one of key elements considered in development of the accident management program. In this study, generally applicable accident management strategies to domestic nuclear power plants are identified through reviewing several accident management programs for the other countries and considering domestic conditions. Identified strategies are as follows; 1) Injection into the Reactor Coolant System, 2) Depressurize the Reactor Coolant System, 3) Depressurize the Steam Generator, 4) Injection into the Steam Generator, 5) Injection into the Containment, 6) Spray into the Containment, 7) Control Hydrogen in the Containment. In addition, the systems and instrumentation necessary for the implementation of .each strategy are also investigated.

  • PDF

Analysis of Earthquake Response Data Recorded from the Hualien Large-Scale Seismic Test (Hualien 대형내진모델시험의 지진응답 계측데이타 분석)

  • 현창헌
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.335-342
    • /
    • 1998
  • A soil-structure interaction (SSI) experiment is being conducted in a seismically active region in Hualien, Taiwan. To obtain earthquake data for quantifying SSI effects and providing a basis to benchmark analysis methods, a 1/4-th scale cylindrical concrete containment model similar in shape to that of a nuclear power plant containment was constructed in the field where both the containment model and its surrounding soil, surface and sub-surface, are extensively instrumented to record earthquake data. In between September 1993 and May 1996, fifteen earthquakes with Richter magnitudes ranging from 4.2 to 6.2 were recorded. The recorded data were analyzed to provide information on the response characteristics of the Hualien soil-structure system, the SSI effects and the ground motion characteristics. The ground response data were analyzed for their variations with depth, with distance from the model structure, and at the same depths along downhole arrays. Variations of soil stiffness and soil-structure system frequencies were also evaluated against maximum ground motion. In addition, the site soil properties were derived based on correlation analysis of the recorded data and then correlated with those from the geotechnical investigation data.

  • PDF

A Study on the Influence Diagrams for the Application to Containment Performance Analysis (격납용기 성능해석을 위한 영향도에 관한 연구)

  • Park, Joon-Won;Jae, Moon-Sung;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.129-136
    • /
    • 1996
  • Influence diagram method is applied to containment performance analysis of Young-Gwang 3&4 in an effort to overcome some drawbacks of current containment performance analysis method. Event tee methodology has been adopted as a containment performance analysis method. There are, however, some drawbacks on event tree methodology. This study is to overcome three major drawbacks of the current containment performance analysis method : 1) Event tree cannot express dependency between events explicitly. 2) Accident Progression Event Tree (APET) cannot represent entire containment system. 3) It is difficult to consider decision making problem. To resolve these problems, influence diagrams, is proposed. In the present ok, the applicability of the influence diagrams has been demonstrated for YGN 3&4 containment performance analysis and accident management strategy assessments of this study are in good agreement with those of YGN 3&4 IPE. Sensitivity analysis has been peformed to identify relative important variables for each early containment failure, late containment and basemat melt-though. In addition, influence diagrams are used to assess two accident management strategies : 1) RCS depressurization, 2) cavity flooding. It is shown that influence diagrams can be applied to the containment performance analysis.

  • PDF