Browse > Article

A Seismic Stability Design by the KEPIC Code of Main Pipe in Reactor Containment Building of a Nuclear Power Plant  

Yi, Hyeong-Bok (Section of Automobile & Energy, Andong Science College)
Lee, Jin-Kyu (Dept. of Plant Engineering, SAMY Industrial Co., LTD.)
Kang, Tae-In (Dept. of Plant Engineering, SAMY Industrial Co., LTD.)
Publication Information
Abstract
In piping design of nuclear power plant facilities, the load stress according to self-weight is important for design values in test run(shutdown and starting). But sometimes it needs more studies, such as seismic analysis of an earthquake of power plant area and fatigue life and stress of thermal expansion and anchor displacement in operating run. In this paper, seismic evaluations were performed to nuclear piping system of Shin-Kori NO. 3&4 being built in Pusan lately. Results of seismic analysis are evaluated on basis of KEPIC MN code. The structural integrity on RCB piping system was proved.
Keywords
Reactor Containment Building; Seismic Analysis; In-Containment Refueling Water Storage Tank; Operating Basis Earthquake; Safe Shutdown Earthquake;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 KEPCO E&C, "Lesson Plan for Training Personnel in Piping Analysis," 2003.
2 Sargent & Lundy, "User's Manual Integrated Piping Analysis System, PIPSYS," EMD-TP-1, Volume I, 2001.
3 ASCE Standard 4-98, "Seismic analysis of safetyrelated nuclear structure and commentary on standard for seismic analysis of safe-related nuclear structures," 1986.
4 Kim, Y. W., Bae, Y. C. and Lee, Y. S., "Countermeasure on high vibration of branch pipe with pressure pulsation transmitted from main steam header," Trans. of the Korean Society for Noise Vibration Engineering, Vol. 15, No. 8, pp. 988 - 995, 2005.   과학기술학회마을   DOI
5 Jhung, M. J. and Choi, Y. H., "Surge line stress due to thermal stratification," Nuclear Engineering and Technology, Vol. 40, No. 3, pp. 239 - 250, 2008.   DOI
6 Huh, N. S., Lee, C. H., Kim, Y. J., Seok, C. S. and Pyo, C. R., "Development of a simplified design method for LBB application to nuclear piping," Journal of KIIS , Vol. 14, No. 2, pp. 32-41, 1999.   과학기술학회마을
7 Yu, Y. J. and Kim, Y. J., "Effect of nozzle on LBB evaluation for small diameter nuclear piping," Trans. of KSME A, Vol. 20, No. 6, pp. 1872-1881 ,1996.   과학기술학회마을
8 KEPIC 2000 Edition.
9 Yun, S. C., Kim, I. Y. and Hwang, I. K., "A review of OBE elimination on evaluation of the code pipe stress and postulation of pipe brake locations," Transmitted of the 17th International Journal Conference on Structural Mechanics in Reactor Technology (SMiRT), Paper No. K 15-5, 2003.
10 KEPIC 1995 Edition.
11 U.S. Nuclear Regulatory Commission, "Combining Modal Responses and Spatial Components in Seismic Response Analysis," Regulatory Guide 1.92, 1992.
12 U.S. Nuclear Regulatory Commission, "Quality Group Classifications and Standards for Water, Steam, and Radioactive Waste Containing Components of Nuclear Power Plants," Regulatory Guide 1.26, Revision 3, 1976.
13 U.S. Nuclear Regulatory Commission, "Seismic Design Classification," Regulatory Guide 1.29, 1992.
14 U.S. Nuclear Regulatory Commission, "Design Limits and Loading Combinations for Seismic Category I Fluid System Components," Regulatory Guide 1.48, 1973.
15 Chopra, A. K., "Dynamic of structures, theory and application to earthquake," Prentice Hall, 1995.