• Title/Summary/Keyword: Contact type

검색결과 2,319건 처리시간 0.032초

골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE)

  • 장경수;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF

이온 이온주입한 p-type 4H-SiC에의 오믹 접촉 형성 (Formation of Ohmic Contacts on acceptor ion implanted 4H-SiC)

  • 방욱;송근호;김형우;서길수;김상철;김남균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.290-293
    • /
    • 2003
  • Ohmic contact characteristics of Al ion implanted n-type SiC wafer were investigated. Al ions implanted with high dose to obtain the final concentration of $5{\times}10^{19}/cm^3$, then annealed at high temperature. Firstly, B ion ion implanted p-well region were formed which is needed for fabrication of SiC devices such as DIMOSFET and un diode. Secondly, Al implanted high dose region for ohmic contact were formed. After ion implantation, the samples were annealed at high temperature up to $1600^{\circ}C\;and\;1700^{\circ}C$ for 30 min in order to activate the implanted ions electrically. Both the inear TLM and circular TLM method were used for characterization. Ni/Ti metal layer was used for contact metal which is widely used in fabrication of ohmic contacts for n-type SiC. The metal layer was deposited by using RF sputtering and rapid thermal annealed at $950^{\circ}C$ for 90sec. Good ohmic contact characteristics could be obtained regardless of measuring methods. The measured specific contact resistivity for the samples annealed at $1600^{\circ}C\;and\;1700^{\circ}C$ were $1.8{\times}10^{-3}{\Omega}cm^2$, $5.6{\times}10^{-5}{\Omega}cm^2$, respectively. Using the same metal and same process of the ohmic contacts in n-type SiC, it is found possible to make a good ohmic contacts to p-type SiC. It is very helpful for fabricating a integrated SiC devices. In addition, we obtained that the ratio of the electrically activated ions to the implanted Al ions were 10% and 60% for the samples annealed at $1600^{\circ}C\;and\;1700^{\circ}C$, respectively.

  • PDF

경간형식과 고속열차 판토그라프 접촉력 특성의 상호관계에 대한 시험적 고찰 (An Experimental Study on the Correlation between Span Types and the Contact Force of the Pantograph for High-speed Train)

  • 김영국;목진용;이희성
    • 한국철도학회논문집
    • /
    • 제8권5호
    • /
    • pp.398-404
    • /
    • 2005
  • In this paper, we introduce the on-line test of the current collection characteristics for HSR 350x(Korea High Speed Train project) that have been performed in the Kyoung-bu high-speed line since 2002. Through the analysis of measured data during on-line test, the variation trend of contact force between pantograph and contact wire of catenary according to the span type, the track conditions and driving patterns is reviewed. In order to analyze the variation trend of contact force, we have checked the span type of catenary in KP 24 - 125 out of Kyoung-bu high speed line and obtained the statistical processing result per each span type. This study shows that the track conditions do not affect on the dynamic performance between pantograph and contact wire catenary, and the span type and the driving pattern are important factors in determining the good interaction between them.

무단 변속기의 동력전달 접촉에서 회전운동을 고려한 타원형상의 점접촉 탄성유체윤활연구 (Study on the Fluid Film Thickness and Pressure of Elliptical Elastohydrodynamic Lubrication with Spin Effect for the Power Transmitting Contact in the Continuously Variable Transmission)

  • 장시열
    • Tribology and Lubricants
    • /
    • 제21권6호
    • /
    • pp.272-277
    • /
    • 2005
  • Continuously variable transmission (CVT) of toroidal type has a elliptical shape of contact zone under the elastohydrodynamic lubrication (EHL) condition, where the power is transmitted only by shearing the lubricant. Due to the small contact area of elliptical shape, the traction of the shear behaviors of lubricant over the contact zone is under extremely high contact pressure over 1.0GPa. During the power transmission by shearing the fluid, many kinds of mechanical movements occur such as squeezing, sliding, rolling and spin. Among the movements, the spin effect that is the most undesirable contact behavior in transmitting the power frequently makes significant abnormal wear damage. In this work, the analysis of elliptical contact of EHL with spin effect is performed, which will give very useful information to understand the traction behaviors in toroidal type of CVT system.

접촉식 자동 형상제어 장치의 특성에 관한 연구 (A Study on Characteristics of Automatic Flatness Control System of Contact Type)

  • 김문경;전언찬;김순경
    • 한국정밀공학회지
    • /
    • 제13권5호
    • /
    • pp.67-73
    • /
    • 1996
  • The necessity for more accurate automatic flatness control(AFC) system has increased of customers' requirement for cold rolled steel sheet. Therefore, many cold rolling mills replaced its AFC system with a measuring roll of the contact type form the non-contact type. In this paper. The performance of AFC system of contact type has been investigated under industrial conditions. It has two kinds of actuator: roll bender, spot cooling system. The test results are as follows: The more strip thickness is thick, the smaller the I value, and the more it is thin, the bigger the I value. And a complex distribution of strip tension was controlled, for example, not only a pocket wave but also a simple center wave and edge wave. Because the tension deviation is larger at acceler- ation speed and decelerationspeed than steady speed, AFC system of contact type is better to adopt over 50m/mim. AFC system reduces rapidly large flatness deviation. The maximum I value of strip has been decreased to 13 I, and sticker, defects caused by poor flatness, have been decreased about 60%.

  • PDF

AgAl 전극 고온 소성 조건 가변에 따른 N-형 결정질 실리콘 태양전지의 접촉 특성 분석 (Analysis of Contact Properties by Varying the Firing Condition of AgAl Electrode for n-type Crystalline Silicon Solar Cell)

  • 오동현;정성윤;전민한;강지윤;심경배;박철민;김현후;이준신
    • 한국전기전자재료학회논문지
    • /
    • 제29권8호
    • /
    • pp.461-465
    • /
    • 2016
  • n-type silicon shows the better tolerance towards metal impurities with a higher minority carrier lifetime compared to p-type silicon substrate. Due to better lifetime stability as compared to p-type during illumination made the photovoltaic community to switch toward n-type wafers for high efficiency silicon solar cells. We fabricated the front electrode of the n-type solar cell with AgAl paste. The electrodes characteristics of the AgAl paste depend on the contact junction depth that is closely related to the firing temperature. Metal contact depth with p+ emitter, with optimized depth is important as it influence the resistance. In this study, we optimize the firing condition for the effective formation of the metal depth by varying the firing condition. The firing was carried out at temperatures below $670^{\circ}C$ with low contact depth and high contact resistance. It was noted that the contact resistance was reduced with the increase of firing temperature. The contact resistance of $5.99m{\Omega}cm^2$ was shown for the optimum firing temperature of $865^{\circ}C$. Over $900^{\circ}C$, contact junction is bonded to the Si through the emitter, resulting the contact resistance to shunt. we obtained photovoltaic parameter such as fill factor of 76.68%, short-circuit current of $40.2mA/cm^2$, open-circuit voltage of 620 mV and convert efficiency of 19.11%.

5-Head Router Machine 의 이면 구속 공구 시스템 (Dual-Contact Tooling System for 5-Head Router Machine)

  • 성승학;이득우;이채문;백효정;옥주선;최운집
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.788-791
    • /
    • 2004
  • This paper presents a general description of single and dual contact tooling systems, finite element analysis, and discussions on the application of the system to the 5-head router machine which is in particular for aerospace components. This study has been performed as part of the development of the new generation 5-head router machine which is designed for high productivity. Such high productivity in essence requires high speed rotation and multiple spindles in one machine. The high speed rotation may exceed a range in a conventional single contact tooling system. The conventional tooling system is reevaluated in comparison with the dual-contact system. Finite element analysis using simplified spindle models compares major differences in the two systems. Some problems in the application to the 5-head router machine are discussed.

  • PDF

액체금속이온이 주입된 p형 GaAs의 오옴성 접촉 (Ohmic Contact of P-type GaAs Implanted the Liquid Metal Ion)

  • 김송강;강태원;홍치유;임재영;엄기석;이재환;위영호;이정주
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1381-1387
    • /
    • 1989
  • For the fabrication of ohmic contact to p-type GaAs, In Liquid Metal Ions were implanted into p-type GaAs (Zn:1.5x10**19/cm**3). After the samples were processed by Infrared rapid thermal annealing (IRTA0 or Furance Annealing (FA), I-V and specific contact contact resistivity were measured. Specific contact resistivity was found to be 1.7x10**-5 \ulcorner-cm\ulcornerin IRTA 750\ulcorner, 10 sec annealed sample. The surface characteristics of the samples were investigated with SEM, RHEED, AES. From these results we can know that implanted In ions were formed mixing layer of InAs at the surface.

  • PDF

A Modeling of Impact Dynamics and its Application to Impact Force Prediction

  • Ahn Kil-Young;Ryu Bong-Jo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권spc1호
    • /
    • pp.422-428
    • /
    • 2005
  • In this paper, the contact force between two colliding bodies is modeled by using Hertz's force-displacement law and nonlinear damping function. In order to verify the appropriateness of the proposed contact force model, the drop type impact test is carried out for different impact velocities and different materials of the impacting body, such as rubber, plastic and steel. In the drop type impact experiment, six photo interrupters in series close to the collision location are installed to measure the velocity before impact more accurately. The characteristics of contact force model are investigated through experiments. The parameters of the contact force model are estimated using the optimization technique. Finally the estimated parameters are used to predict the impact force between two colliding bodies in opening action of the magnetic contactor, a kind of switch mechanism for switching electric circuits.

정전용량형 센서를 이용한 기상계측시스템의 개발 (Development of On-machine Measurement System utilizing a Capacitive-type Sensor)

  • 김건희;박순섭;박원규;원종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF