• Title/Summary/Keyword: Contact patch

Search Result 94, Processing Time 0.024 seconds

The Contact Fatigue Life Analysis of Rough Surfaces (거친 표면의 접촉피로 수명예측)

  • Chu Hyo-Jun;Lee San-Don;Cho Yong-Joo
    • Tribology and Lubricants
    • /
    • v.21 no.3
    • /
    • pp.136-141
    • /
    • 2005
  • Analytical model to calculate the contact fatigue life of rough surface is presented in this paper. The effect of surface roughness can be calculated by this model. Computational method and the theoretical basis are also discussed. Contact stresses are obtained by contact analysis of a semi-infinite solid based on the use of influence functions; the subsurface stress field is obtained using rectangular patch solutions. Mesoscopic multiaxial fatigue criterion which can yield satisfactory results for non-proportional loading is then applied to predict fatigue damage. Suitable counting method and damage rule were used to calculate the fatigue life of random loading caused by rough surface. As a result of analysis the relationship between the life and the roughness as well as the most probable depth of the crack initiation is calculated.

The Contact Fatigue Life Analysis of Transmission Gear considering Running-in (길들이기 과정을 고려한 변속기용 기어의 접촉피로 수명 해석)

  • Moon, Kil-Hwan;Lee, Sang-Don;Cho, Yong-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.133-138
    • /
    • 2007
  • Surface pitting is a major failure mode for gears. The contact fatigue life analysis of transmission gear considering running-in process is presented in this paper. Surface roughness change of rolling test is used in a life analysis. Contact stresses are obtained by contact analysis of a semi-infinite solid based on the use of influence functions; the subsurface stress field is obtained using rectangular patch solutions. Mesoscopic multiaxial fatigue criterion which can yield satisfactory results for non-proportional loading is then applied to predict fatigue damage. Suitable counting method and damage rule were used to calculate the fatigue life of random loading caused by rough surface. The life analysis considering running-in is in good agreement with the experimental results.

Sub­surface Stress Distribution beneath the Contact Surface of the Gear Teeth for Two Profile Models (치면 프로파일 모델에 따른 기어 치면 내부의 응력 분포)

  • 구영필;오명석;김형자;김영대
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.357-364
    • /
    • 2003
  • The sub­surface stress field beneath the gear's contact surface caused by the contact pressure in lubricated condition has been calculated. To evaluate the influence of the clearance shape on the stress field, two kinds of tooth profile models were chosen. One is the conventional cylinder contact model and the other is the new numerical model. Love's rectangular patch solution was used to obtain the sub­surface stress field. The analysis results show that the sub­surface stress is quite dependent on both the contact pressure and the profile model. The maximum effective stress of the new model is lower than that of the old model. The depth where the maximum effective stress occurs in the new model is not proportional to the intensity of the external load.

The Subsurface Stress Field Caused by Both Normal Loading and Tangential Loading

  • Koo Young- Phi;Kim Tae-Wan;Cho Yong-Joo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1967-1974
    • /
    • 2005
  • The subsurface stress field caused by both normal loads and tangential loads has been evaluated using the rectangular patch solution. The effect of tangential loading on the subsurface stress field has been investigated in detail for both the cylinder-on-cylinder contact and a spur gear teeth contact. For the cylinder-on-cylinder contact, the subsurface stress fields are moved more to the direction of tangential loads and the positions where the maximum stress occur are getting closer to the surface with the increasing tangential loads. The subsurface stress fields of the gear teeth contact are expanded more widely to the direction of tangential loads with the increasing tangential loads. The friction coefficient of a gear teeth contact is low because they are operated in a lubricated condition, and therefore surface tractions in the EHL condition hardly affect on the subsurface stress field.

Contact Fatigue Life Prediction of Automotive Wheel Bearing (차량용 휠베어링의 접촉 피로수명 예측에 관한 연구)

  • Lee, Sang-Don;Moon, Kil-Hwan;Cho, Yong-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.137-143
    • /
    • 2008
  • For most bearings, it is a common requirement to have long durability. Especially wheel bearing fatigue life is the most important in automotive quality. The contact fatigue life analysis of automotive wheel bearing considering real raceway rough surface is presented in this paper. Contact stresses are obtained by contact analysis of a semi-infinite solid based on the use of influence functions; the subsurface stress field is obtained using rectangular patch solutions. Mesoscopic multiaxial fatigue criterion which can yield satisfactory results for non-proportional loading is then applied to predict fatigue damage. Suitable counting method and damage rule were used to calculate the fatigue life of random loading caused by rough surface. The life analysis considering real rough surface of wheel bearing raceway is in good agreement with the experimental results.

The Effect of Surface Roughness on the Contact Fatigue Life (표면 거칠기가 접촉피로 수명에 미치는 영향)

  • Chu Hyo-Jun;Lee Sang-Don;Cho Yong-Joo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.1033-1036
    • /
    • 2005
  • The effect of surface roughness on the contact fatigue was investigated in this study. To accomplish this goal, contact analysis based on the influence functions and the rectangular patch solution was performed to obtain the subsurface stress. Mesoscopic multiaxial fatigue criterion is then applied to predict fatigue damage. Suitable counting method and damage rule were used to evaluate the fatigue life of random loading caused by rough surface. As a result of the analysis, relationship between the life and roughness as well as the creack initiation depth was revealed. Below the critical roughness, It is observed that the fatigue life has hardly changed and creack is initiated around the depth at which the maximum shear stress occurs. Different behavior, however, is observed in case that the roughness is above the critical value.

  • PDF

Design and analyes of reconfigurable inset-fed microstrip patch antennas for wireless sensor Networks (무선 센서 네트워크용 주파수 조정이 가능한 마이크로 스트립 패치 안테나 설계 및 해석)

  • Phan, Duy Thach;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.129-129
    • /
    • 2009
  • In this paper, a tunable microstrip patch antenna designed using RF MEMS switches is reported. The design and simulation antenna were performed using high frequency structure simulator (HFSS). The antenna was designed in ISM Band and operates simultaneously at 2.4 GHz and 5.7 GHz with a -10 dB return-loss bandwidth of 20 MHz and 180 MHz, respect-tively. To obtain high efficiency and improve integrated ability, the High Resistivity Silicon (HRS) wafer was used for the antenna. The antenna achieved high gain with 8 dB at 5.7 GHzand 1.5 dB at 2.4 GHz. The RF MEMS DC contact switches was simulated and analysis by ANSYS software.

  • PDF

Extracted Catechin Incorporated Chitosan Patch for Dermal Drug Delivery Systems

  • Seunghwan Choy
    • Korean Journal of Materials Research
    • /
    • v.33 no.11
    • /
    • pp.458-464
    • /
    • 2023
  • In order to develop catechin patches for skin regeneration at wound sites, patches with varying concentrations of catechin and chitosan were manufactured. An optimal composition ratio was determined by adjusting the drug release rate and amount, to maximize efficiency. The catechin used in this study was extracted from green tea leaves using a solvent/ultrasonication method, and its characteristics were confirmed through Fourier transform-infrared spectroscopy (FT-IR) and high-performance liquid chromatography (HPLC) analyses. Patches were prepared with different concentrations of catechin and chitosan, and various properties were analyzed using techniques such as FT-IR, water contact angle analysis, and UV-Vis spectroscopy. It was observed that as the chitosan concentration increased, the release of catechin slowed down or almost ceased. A patch manufactured with 1.5 mg/cm2 of catechin at a 1 % chitosan concentration exhibited a high initial release rate over 24 h and demonstrated cellular biocompatibility. Consequently, these patches, with tailored release characteristics based on the concentrations of chitosan and catechin, hold promise for use as drug delivery systems in wound healing applications.

Slotted Waveguide Array Antenna using Dumbbell Patch for Millimeter-Wave (Dumbbell 패치를 이용한 밀리미터파 대역 슬롯 도파관 안테나)

  • 이정수;성영제;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.353-359
    • /
    • 2004
  • In this paper, the single-layer slotted waveguide array antenna is designed, which consists of two par the slot plate and the structure of waveguide. The key difficulty in mass production is the realization of perfect electrical contact between the two parts. Therefore the single-layer slotted waveguide array antenna is presented with a dumbbell patch and a choke. The choke can prevent from the leakage between the slot plate and waveguide, while the choke in the adjacent waveguide incurs space dissipation. To reduce the spacing of antennas about a dumbbell patch is utilized. the 16${\times}$16 array antenna gain of 27.2 ㏈ with 45 % aperture efficiency is obtained.

Iatrogenic Spark Burn Injury to the Chest From a Transcutaneous Pacing Patch (경피적 심장 충격 장치의 사용으로 발생한 의인성 전기 화상의 증례 보고)

  • Choi, Jong Yun;Cha, Won Jin;Jung, Ee Room;Seo, Bommie Florence;Jung, Sung-No
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.50-52
    • /
    • 2021
  • Iatrogenic electrical burns that occur from the use of a defibrillator, a paddle-type cardiac shock device, have been reported in various forms. Electrical burns are usually conducted directly through the skin and are more damaging than scald burns or contact burns. A transcutaneous cardiac pacing device is a patch-type cardiac shock device that automatically delivers a shock when an abnormal heart rhythm is detected. We introduce a unique case of iatrogenic electrical burns caused by the transcutaneous pacing patch of a cardiac shock device. Electrical energy was converted into a spark due to foreign bodies deposited around the patch, resulting in damage to the peripheral area of the skin.