• Title/Summary/Keyword: Contact Treatment

Search Result 1,610, Processing Time 0.029 seconds

Early Intervention for Low-Temperature Burns: Comparison between Early and Late Hospital Visit Patients

  • Choi, Matthew Seung Suk;Lee, Ho Joon;Lee, Jang Hyun
    • Archives of Plastic Surgery
    • /
    • v.42 no.2
    • /
    • pp.173-178
    • /
    • 2015
  • Background Various focal heating devices are popular in Korea under the cultural influence of the traditional ondol under-floor method of home heating. These devices can cause severe burn-like injuries resulting from device malfunction or extended with low heat contact. In addition to injuries under these high heat contact, burns can be occurred by low heat exposure with prolonged periods despite the devices are properly functioning. In order to develop strategies to reduce the duration of periods of illness due to low-temperature burns, we analyzed and compared treatment methods and therapeutic periods for this type of injury. Methods This retrospective study included 43 patients burned under low heat conditions. Patients were divided into an operative group and a conservative group. The patients in the operative group underwent at least one surgical excision, and were further subdivided into early and late visit groups. The conservative group was treated only with dressings. We compared the treatment periods between the operative group and the conservative group, and also compared the preparation periods and treatment periods between the two operative groups. Results The average treatment period was significantly shorter in the operative group (P=0.02). In the early visit operative group, both wound preparation and treatment were briefer than in the late visit group. Conclusions We recommend that early proper burn care and early surgical intervention, including appropriate excision, are feasible ways to reduce the treatment period of lowtemperature burn patients.

Evaluation on the Locations of Powdered Activated Carbon Addition for Improvement of Taste and Odor Removal in Drinking Water Supplies (상수원수 내 이취미 제거효율 향상을 위한 분말활성탄 투입지점의 평가)

  • Kim, Young-Il;Lee, Sang-Jin;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.341-348
    • /
    • 2007
  • The efficiency of powdered activated carbon (PAC) for removing taste and odor (T&O) in drinking water supplies is dependent on the contact time, quality of mixing, and the presence of competing compounds. All of these are strongly influenced by the stage in the treatment process at which the PAC is added. In conventional water treatment plants (WTPs), PAC is commonly added into the rapid mixing basin where chemicals such as coagulants, alkaline chemicals, and chlorine, are simultaneously applied. In order to prevent interference between PAC and other water treatment chemicals, alternative locations for addition of PAC, such as at transmission pipe in the water intake tower or into a separated PAC contactor, were investigated. Whatever the location, addition of PAC apart from other water treatment chemicals was more effective for geosmin removal than simultaneous addition. Among several combinations, the sequence 'chlorine-PAC-coagulant' produced the best result with respect to geosmin removal efficiency. Consequently, when PAC has to be applied to cope with T&O problems in conventional WTPs, it is very important to prevent interference with other water treatment chemicals, such as chlorine and coagulant. Adequate contact time should also be given for adsorption of the T&O compounds onto the PAC. To satisfy these conditions, installation of a separated PAC contactor would be the superior alternative if there is space available in the WTP. If necessary, PAC could be added at transmission pipe in the water intake tower and still provide some benefit for T&O treatment.

Optimization of polymer substrate's surface treatment for improvement of transparent conducting oxide thin film (투명전도막의 특성향상을 위한 기판 표면처리법의 최적화)

  • Choi, Woo-Jin;Kim, Ji-Hoon;Jung, Ki-Young;Darma, Jessie;Choo, Young-Bae;Sung, Youl-Moon;Kwak, Dong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1425_1426
    • /
    • 2009
  • In this study, commercially available polyethylene terephthalate(PET), which is widely used as a substrate of flexible electronic devices, was modified by dielectric barrier discharge(DBD) method in an air condition at atmospheric pressure, and aluminium - doped zinc oxide (ZnO:Al) transparent conducting film was deposited on PET substrate by r. f. magnetron sputtering method. Surface analysis and characterization of the plasma-treated PET substrate was carried out using contact angle measurements, X-ray Photoelectron Spectroscopy(XPS) and Atomic Force Microscopy (AFM). Especially the effect of surface state of PET substrate on some important properties of ZnO:Al transparent conducting film such as electrical and morphological properties and deposition rate of the film, was studied experimentally. The results showed that the contact angle of water on PET film was reduced significantly from $62^{\circ}$ to $43^{\circ}$ by DBD surface treatment at 20 min. of treatment time. The plasma treatment also improved the deposition rate and electrical properties. The deposition rate was increased almost linearly with surface treatment time. The lowest electrical resistivity as low as $4.97{\times}10^{-3}[\Omega-cm]$ and the highest deposition rate of 234[${\AA}m$/min] were obtained in ZnO:Al film with surface treatment time of 5min. and 20min., respectively.

  • PDF

A Study on the Joint Property by the Surface Treatment Method on the Jointing Method of PET Film using the High Hardness Liquid (고경질 도막을 이용한 PET 필름 접합공법의 필름 표면처리 방법에 따른 접합특성 연구)

  • Lee, Jong-Suk;Kim, Young-Sam;Shin, Hong-Chol;Kim, Young-Geun;Kang, Chung-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • This research reviewed the joint and duration characteristics depending on the surface treatment condition and lap spliced length in the PET film jointing method using the high hardness liquid material. As a result, the corona discharge treatment was improved to the contact angle, joint tensile strength, and joint peel resistance compared to non-treatment. Particularly, a surface treatment E (Corona discharge + Primer + PU bond + Polyester fabric) turned out to the best, and especially when the lap spliced length is longer than 15mm, stable joint performance was secured under the long term deterioration treatment of 16 weeks. Thus, the joint is considered to be applicable as the water-proof material.

One Case Report of Prurigo Nodularis Patients Improved by Korean Medicine Treatment alone with Whidam's Su-Gi Therapy (휘담식 수기요법을 병행한 결절성(結節性) 양진(痒疹)의 한의(韓醫) 단독(單獨) 치험(治驗) 1 례(例))

  • Pi, Chien Mei;Jung, Jae Hun;Lee, Eun Mi;Lee, Jae Heung;Bae, Jae Ryong
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.18 no.1
    • /
    • pp.113-145
    • /
    • 2018
  • Objective : The purpose of this study is to report about a mid-40's female patient with Prurigo Nodularis, whose symptoms were relieved after Korean medicine treatment alone with Whidam's Su-Gi Therapy. Methods : the patient in this study received only Korean medicine treatment such as herbal medication, acupuncture treatment, cupping therapy and specially Whidam's Su-Gi therapy. Results : After the treatment, the symptoms of Prurigo Nodularis were relieved. Contact Itching Index fell from 10 to 5, and Non-Contact Itching Index fell from 10 to 4. On the whole the Body Heat has risen and skin condition has improved visually. The significance of Meridian Function Check(based on HRV) and skin syndrome is remarkable., Conclusions : This study showed that Whidam's Su-Gi therapy added with Korean Medicine treatment can be an effective choice for Prurigo Nodularis. So, wasting disease, especially immune-reduced syndrome such as Prurigo Nodularis, may also be treated with Korean Medicine alone without side effects.

The Effect of Acid Treatment on the Adhesion Property of Polyketone with Rubber (폴리케톤과 고무의 접착성에 미치는 산처리의 영향)

  • Choi, Hae Young;Lee, Tae Sang;Lee, Jong;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.12 no.1
    • /
    • pp.26-33
    • /
    • 2011
  • Phosphoric acid treatments were conducted to improve the adhesion property of polyketone film to rubber. The effects of phosphoric acid treatments were characterized by using a contact angle analyzer and a XPS (X-ray photoelectron spectroscopy). Morphological changes were observed by using a scanning electron microscope (SEM) and an atomic force microscope (AFM) as the acid treatment condition varied in concentration and time. The contact angle was found to significantly decrease with the acid treatment. According to the XPS, increased wettability was attributed to the inclusion of oxygen containing groups such as hydroxyl, carbonyl and carboxyl by acid treatments. Cracks and pores were produced on the polyketone film surface and thus, roughness increased with the acid treatment. Interfacial adhesion strength between polyketone and natural rubber was largely improved by acid treatment due to the increased wettability and roughness of the polyketone surface. However, the higher level of acid treatment caused the degradation of the polyketone surface, and thus, its interfacial adhesion consequently decreased.

The morphological study of Cornea in Man College Students (남자대학생들의 각막 형태 연구)

  • Kim, Douk Hoon;Yoo, Jae Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • The physiology and morphology of cornea has effected on the ocular refractive status. Therefore the measurement of the anterior corneal surface by keratometer is used the treatment of the spectacles and contact lens by optician, optometrist, and ophthalmologist. Furthermore, currently the most corneal topographic mapping system have used the clinical optical shop, eye research center, and eye hospital. Because this method have a very fine data comparative to the previous instrument. The authors have measurement the cornea of the man college students by the corneal topographic mapping method. Especially this data will applied the clinical practice for the contact lens fitting. Especially in Korea, many man college students use the contact lens for the visual acuity and a beauty. Therefore the contact lens wear have increase per every year.

  • PDF

The Electrical Properties of GaN Individual Nanorod Devices by Wet-etching of the Nanorod Surface and Annealing Treatment (표면 습식 식각 및 열처리에 따른 GaN 단일 나노로드 소자의 전기적 특성변화)

  • Ji, Hyun-Jin;Choi, Jae-Wan;Kim, Gyu-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.152-155
    • /
    • 2011
  • Even though nano-scale materials were very advantageous for various applications, there are still problems to be solved such as the stabilization of surface state and realization of low contact resistances between a semiconducting nanowire and electrodes in nano-electronics. It is well known that the effects of contacts barrier between nano-channel and metal electrodes were dominant in carrier transportation in individual nano-electronics. In this report, it was investigated the electrical properties of GaN nanorod devices after chemical etching and rapid thermal annealing for making good contacts. After KOH wet-etching of the contact area the devices showed better electrical performance compared with non-treated GaN individual devices but still didn't have linear voltage-current characteristics. The shape of voltage-current properties of GaN devices were improved remarkably after rapid thermal annealing as showing Ohmic behaviors with further bigger conductivities. Even though chemical etching of the nanorod surfaces could cause scattering of carriers, in here it was shown that the most important and dominant factor in carrier transport of nano-electronics was realization of low contact barrier between nano-channel and metal electrodes surely.

Stepwise Ni-silicide Process for Parasitic Resistance Reduction for Silicon/metal Contact Junction

  • Choi, Hoon;Cho, Il-Whan;Hong, Sang-Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.137-142
    • /
    • 2008
  • The parasitic resistance is studied to silicon/metal contact junction for improving device performance and to lower contact/serial resistance silicide in natural sequence. In this paper constructs the stepwise Ni silicide process for parasitic resistance reduction for silicon/metal contact junction. We have investigated multi-step Ni silicide on SiGe substrate with stepwise annealing method as an alternative to compose more thermally reliable Ni silicide layer. Stepwise annealing for silicide formation is exposed to heating environment with $5^{\circ}C/sec$ for 10 seconds and a dwelling for both 10 and 30 seconds, and ramping-up and the dwelling was repeated until the final annealing temperature of $700\;^{\circ}C$ is achieved. Finally a direct comparison for single step and stepwise annealing process is obtained for 20 nm nickel silicide through stepwise annealing is $5.64\;{\Omega}/square$ at $600\;^{\circ}C$, and it is 42 % lower than that of as nickel sputtered. The proposed stepwise annealing for Ni silicidation can provide the least amount of NiSi at the interface of nickel silicide and silicon, and it provides lower resistance, higher thermal-stability, and superior morphology than other thermal treatment.

Local Back Contact Formed by Screen Printing and Atomic Layer Deposited Al2O3 for Silicon Solar Cell

  • Jo, Yeong-Jun;Jang, Hyo-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.687-687
    • /
    • 2013
  • In rearpoint contact solar cell and the PERC (passivated emitter rear contact) type cell, surfaces were passivated by SiO2 or Al2O3 to increase solar cell efficiency. Therefore, we have investigated the effect of surface passivation for crystalline silicon solarcell using mass-production atomic layer deposited (ALD) Al2O3. The patttern which consists of cylinders with 100um diameter and 5um height was formed by PR patterning on Si (100) substrate and then Al2O3 of about 10nm and 20nm thickness was deposited by ALD. The pattern in 10 nm Al2O3 film was removed by dipping in aceton solution for about 10 min but the pattern in 20 nm Al2O3 film was not. The influences of process temperature and heat treatment were investigated using microwave photoconductance decay (PCD) and Quasi-Steady-State photoconductance (QSSPC). The solar cell process used in this work combines the advantage of using the applicability of a selective deposition associated with a ALD passivation and the use of low-cost screen print for the contacts formation.

  • PDF