• Title/Summary/Keyword: Contact Time

Search Result 3,209, Processing Time 0.029 seconds

Experimental Study of Laser Assisted Microvascular Anastomosis(LAMA) Using the Nd:YAG Contact Laser (Laser를 이용한 새로운 미세혈관 문합술의 실험적 연구)

  • Cho, Jin-Hwan;Lim, Jae-Ho;Park, Seung-Ha;Kim, Woo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.82-92
    • /
    • 1993
  • A comparative study was undertaken to evaluate the contact Neo-dymium : yttrium aluminum garnet(Nd:YAG) laser system for vascular anastomosis of small caliber blood vessels(diameter 0.5-1.2 mm) in the animal model. In this study 40 femoral arteries and 40 femoral veins of Sprague-Dawley rats were anastomosed by contact laser assisted microvascular anastomosis(LAMA) utilizing 3 stay sutures which were placed 120 degrees apart and the intervals welded with contact Nd:YAG laser unit, conventionally sutured anastomosis(CSA) served as controls. The time needed for vascular anastomosis, patency rate(immediate postoperative, postoperative 2nd day, postoperative 1 week, postoperative 4 weeks), gross and microscopic evaluations were compared to conventional microsurgical suture technique. The results are as follows: 1. Postoperative patency rate was 82.5% for femoral artery and 75% for femoral vein by contact LAMA technique compared to 90% and 75% by CSA technique at postoperative 4 weeks. 2. Less time-consumed for arterial anastomosis by 6 minutes 23 seconds and venous anastomosis by 8 minutes 55 seconds with contact LAMA technique compared to CSA technique. 3. Grossly almost complete healing had taken place by postoperative 1 week by contact LAMA technique. 4. Aneurysm formation was 5% for femoral artery and 15% for femoral vein by contact LAMA technique compared to 5% and 10% respectively by CSA technique. 5. Microscopically, re-endothelization was complete by postoperative 7th day by contact LAMA technique. There was less medial hypertrophy and hyperplasia and also less inflammatory response compared to CSA.

  • PDF

A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns (교모면적과 교합접촉양태 간의 관계에 대한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

V-t Characteristics and Survival Probability of Turn-to-Turn Models for HTS Transformer (고온초전도 변압기를 위한 턴간 모델의 V-t 특성 및 생존 확률)

  • Baek, Seung-Myeong;Cheon, Hyeon-Gweon;Nguyen, Van-Dung;Seok, Bok-Yeol;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.356-362
    • /
    • 2004
  • Using multi wrapped copper by polyimide film for HTS transformer, the breakdown and V-t characteristics of two type models for turn-to-turn, one is point contact model, the other is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on V-t characteristics under at voltage as well as breakdown voltage under ac and impulse voltage in $LN_2$ was carried. Also, survival analysis was performed according to the Kaplan-Meier method. The breakdown voltages for surface contact model are lower than that of the point contact model, because the contact area of surface contact model is wider than that of point contact model. At the same time, the shape parameter of the point contact model is a little bit larger than the of the surface contact model. The time to breakdown tn is decreased as the applied voltage is increased, and the lifetime indices slightly are increased as the number of layers is increased. According to the increasing applied voltage and decreasing wrapping number, the survival probability is increased.

  • PDF

Development of Contact Algorithms for Three Dimensional Surfaces (삼차원 곡면에 대한 접촉해석기법의 개발)

  • 박채현;박종진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1994.10a
    • /
    • pp.157-164
    • /
    • 1994
  • Finite element analysis of material deformation is successfully utilized to understand metal forming processes such as forging, extrusion and deep drawing. However, such analysis involves contact problems; a free node touches a die surface and a contact node slips along the die surface. In the present investigation, appropriate contact algorithms were developed assuming that a three dimensional surface can be divided into bilinear patches and that nodal velocities are linear during an incremental time. The algorithms were coded into a computer program and tested for a simple surface. Comparison of the test result with that obtained from a commercial code is presented and discussed.

  • PDF

A study on deburring task of robot arm using neural network (신경망을 이용한 ROBOT ARM의 디버링(Deburring) 작업에 관한 연구)

  • 주진화;이경문;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.139-142
    • /
    • 1996
  • This paper presents a method of controlling contact force for deburring tasks. The cope with the nonlinearities and time-varying properties of the robot and the environment, a neural network control theory is applied to design the contact force control system. We show that the contact force between the hand and the contacting surface can be controlled by adjusting the command velocity of a robot hand, which is accomplished by the modeling of a robot and the environment as Mass-Spring-Damper system. Simulation results are shown.

  • PDF

Development of Managing System of Vision Probe for CMM (3차원 측정기용 비젼프로브 운용시스템 개발)

  • 박재성;박희재;김구영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.501-505
    • /
    • 1996
  • In CMM system, a contact probe is not applicable to very small, or flexible elements. There is need to develop non-contact probes of CCD camera. But non-contact probes have some technical problems, including distortion, user interface and time delay. This development gives the foundation of the non-contact probe system and some useful solutions for the problems. The results can be useful for industry application.

  • PDF

Effect of cell wall degrading enzyme and skin contact time on the brewing characteristics of Cheongsoo grape (청수 포도의 양조특성에 미치는 세포벽분해효소와 침용시간의 영향)

  • Jeon, Jin-A;Park, Seo-Jun;Yeo, Soo-Hwan;Choi, Ji-Ho;Choi, Han-Seok;Kang, Ji-Eun;Jeong, Seok-Tae
    • Food Science and Preservation
    • /
    • v.20 no.6
    • /
    • pp.846-853
    • /
    • 2013
  • We investigated the effect of the cell-wall-degrading enzyme and its skin contact time on the brewing characteristics of Cheongsoo grape. The easy of juice extraction was excellent at the cell-wall-degrading enzyme and skin contact treatments, and the aroma was best after five days of skin contact treatment. Furthermore, the juice yields of the Chengsoo grape were more dramatically increased by the cell-wall-degrading enzyme and skin contact treatments than by the control. The data on the pH, total acidity, and soluble solids did not significantly differ among the treatments, and the pH range from 3.1 to 3.4; the total acidity from 0.5% to 0.6% (as tartaric acid); and the soluble solids, from 6.7 to 7.1 $^{\circ}Brix$. The alcohol content of cell-wall-degrading enzyme treatment was highest with 13.3%. The total polyphenol was gradually increased with the longer skin contact time, and was highest after 10 days of skin contact treatment, at 306.4 mg/L. The main organic acids detected in the Cheongsoo wine were malic and tartaric acid, and citric, succinic and lactic acid were also detected. Our results show that the cell-wall-degrading enzyme and skin contact treatments were better in terms of the easy of juice extraction and significantly increased the juice yield and the volatile compound of the Cheongsoo wine.

Evaluation of Gas Metal Arc Welding Characteristics according to Contact Tip Materials (GMA용접에서 콘택트 팁 재질에 따른 용접특성 평가)

  • Kim, Dong Yoon;Hwang, In Sung;Kim, Dong Cheol;Kang, Moon Jin
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • The contact tip for gas metal arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. If the contact tip is damaged, it is a cause of lowering the welding productivity due to removal of welding defects and replacement of contact tip. In case of the use of a contact tip for a long time the arc is unstable because the processed hole in the contact tip center is larger, and the variation of aiming position of the welding wire causes a seam tracking error. In this study, gas metal arc welding experiments using contact tip of three different materials were performed. The contact tips with Cu-P, Cu-Cr, and Cu-ODS were used at the experiments, and the welding characteristics by each contact tip were evaluated. After welding contact tip appearance, welding spatter adhesion amount of the nozzle, and weld bead appearance were evaluated. The welding current and welding voltage were measured to verify arc stability during arc welding.

Behaviors of turn-to-turn contact resistance (Rc) of various REBCO CC tapes according to applied contact pressure

  • Jeong, Chanhun;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • No-insulation (NI) pancake magnets are fabricated using Rare earth-Barium-Copper Oxide (REBCO) coated conductor (CC) tapes, which enabled a very compact magnet in the aspects of high critical current density ($J_c$) and high mechanical strength by removing insulation and allowing thinner stabilizer. They have also advantages such as self-quench protection. Therefore, it does not need quench detection and protection that can be very challenging in a high critical temperature ($T_c$) superconducting magnet technology. Recently, it was reported that the NI REBCO CC magnets have some drawbacks of long charging time and high field ramp loss which will be a concern in the operation of cryocooled magnets. These issues are related to the turn-to-turn contact resistivity and can be released by managing it. This is also closely related to the activity of reducing the contact joint resistance in the case of CC joints for long length CC fabrication. Therefore, in this study, the turn-to-turn contact resistance ($R_c$) at the CC contact part of differently stabilized CC tapes was measured. The behaviors of $R_c$ at CC contact parts according to the applied contact pressure were investigated. The range of $R_c$ measured for CC tapes adopted will provide fundamental data for design and fabrication of the CC NI coils.

A Study of the Effects of Behavior Contact in Early Mother-Infant Attachment (분만 직후 어머니의 신생아 접촉이 모아애착행위에 미치는 영향)

  • Sung Mi-Hae;Kim Mi-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.5
    • /
    • pp.842-849
    • /
    • 2005
  • Purpose: The main purpose of this study was to establish a nursing intervention data base to improve maternal attachment. Method: The first group of mothers( control group), experienced their first physical contact with their infants after being discharged from the hospital. The second group (experimental group) practiced early initial mother-infant postpartum contact known as the most sensitive period for founding maternal-infancy attachment. The subjects of this study gave birth to normal infants at M hospital from Aug.25 to Sept.30, 2004. During the same time, data was collected through direct observation, with instruments designed by Cropley et al., to assess the behaviors of normal attachment. The statistical methods for data analysis were percentage, mean, standard deviation and t-test with an SPSS program. Result: The group practicing initial mother-infant contact, showed a higher degree of physical and functional bonding than the group experiencing the first contact after discharge from the :10spital (control group)(p<.0l). The group practicing initial mother-infant contact, showed higher degrees of bonding attachment assessments than the group experiencing their first initial contact after their discharge from the hospital(p<.01). Conclusion: The group practicing early mother-infant contact, showed more maternal-infant interaction than the group experiencing their initial contact after their discharge from the hospital. These results show that maternal attachment behavior increases according with an early initial mother-infant contact.