• Title/Summary/Keyword: Contact Stability

Search Result 747, Processing Time 0.033 seconds

Parametric Design of Contact-Free Transportation System Using The Repulsive Electrodynamic Wheels (반발식 동전기 휠을 이용한 비접촉 반송 시스템의 변수 설계)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.310-316
    • /
    • 2016
  • We propose a novel contact-free transportation system in which an axial electrodynamic wheel is applied as an actuator. When the electrodynamic wheel is partially overlapped by a fixed conductive plate and rotates over it, three-axis magnetic forces are generated on the wheel. Among these forces, those in the gravitational direction and the lateral direction are inherently stable. Therefore, only the force in the longitudinal direction needs to be controlled to guarantee spatial stability of the wheel. The electrodynamic wheel consists of permanent magnets that are repeated and polarized periodically along the circumferential direction. The basic geometric configuration and the pole number of the wheel influence the stability margin of a transportation system, which would include several wheels. The overlap region between the wheel and the conductive plate is a dominant factor affecting the stiffness in the lateral direction. Therefore, sensitivity analysis for the major parameters of the wheel mechanism was performed using a finite element tool. The system was manufactured based on the obtained design values, and the passive stability of a moving object with the wheels was verified experimentally.

Contact non-linear finite element model analysis of initial stability of mini implant (접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구)

  • Yoon, Hyun-Joo;Jung, Ui-Won;Lee, Jong-Suk;Kim, Chang-Sung;Kim, Jung-Moon;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Sung-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

Performance Test of $3^{rd}$ rail type power collector for rubber-tired AGT light rail vehicle (고무차륜 AGT 경량전철 차량용 제 3 궤조 집전장치의 성능시험)

  • Park S.H.;Kim Y.S.;Kim K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1341-1344
    • /
    • 2005
  • This study was aimed to verify the acceptable contact force between power collector and 3rd rail type conductor rail for the Korean standardized rubber-tired AGT light rail vehicle. The power collector was designed and manufactured to satisfy the Korean standardized Specifications of the rubber-tired AGT light rail vehicle. Based on the dynamic behavior, contact force variation and interruption in the worst installation tolerance of the conductor rail, its initial contact force was set up. At the test track for the Korean standardized rubber-tired AGT light rail vehicle, interruptions, stresses, vibrations, and contact force variations were measured. As the results, initial contact force was verified to ensure power collection stability.

  • PDF

Simulation of Vehicle-Track-Bridge Dynamic Interaction by Nonlinear Hertzian Contact Spring and Displacement Constraint Equations (비선형 헤르쯔 접촉스프링과 변위제한조건식의 적용에 의한 차량-궤도-교량 동적상호작용 수치해석기법)

  • Chung Keun-Young;Lee Sung-Uk;Min Kyung-Ju
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.191-196
    • /
    • 2005
  • In this study, to describe vehicle-track-bridge dynamic interaction phenomena with 1/4 vehicle model, nonlinear Hertzian contact spring and nonlinear contact damper are introduced. In this approach external loads acting on 1/4 vehicle model are self weight of vehicle and geometry information of running surface. The constraint equation on contact surface is implemented by Penalty method. Also, to improve the numerical stability and to maintain accuracy of solution, the artificial damper and the reaction from constraint violation are introduced. A nonlinear time integration method, in this study, Newmark method is adopted for both equations of vehicles and structure. And to reduce the error caused by inadequate time step size, adaptive time-stepping technique is partially introduced. As the nonlinear Hertzian contact spring has no resistance to tensile force, the bouncing phenomena of wheelset can be described. Thus, it is expected that more versatile dynamic interaction phenomena can be described by this approach and it can be applied to various railway dynamic problems.

  • PDF

A case study of large-scale slope failure in Granite - Andesite contact area (화강암-안산암 접촉부 대규모 사면의 붕괴 사례 연구)

  • 이수곤;양홍석;황의성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.503-508
    • /
    • 2003
  • In this study, we peformed ahead a field geological investigation, boring investigation for slope stability analysis in large scale slope failure area. But the geological stratum was not clearly grasped, because ground was very disturbed by large scale Granite intrusion. Furthermore, the existing test data was not pertinent to the large scale Granite intrusion site like here. Therefore, various kind of field test were performed to grasp clearly for geological stratum. And the results of back analysis, various kind tests used to slope stability analysis.

  • PDF

DIMENSIONAL STABILITY AND WETTABILITY OF RUBBER IMPRESSION MATERIALS (고무 인상재의 크기 안정성 및 친수성에 관한 연구)

  • Kang Choong-Hee;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.233-245
    • /
    • 1992
  • The purpose of this study was to evaluate the demensioal stability and wettability of several rubber impression materials. Impressions were made from a metal master die machined to stimulate five full veneer crown preparations symmetrically placed in an arch form. Cast from impressions were measured about ; 1) intrapreparation distance 2) lower base diameter 3) length. For comparing materials were formed against a smooth surface. The advancing contact angle of a saturated aqueous solution of $CaSO_4$ on the impression materials was measured after 1 minute. Mean contact angle were calculated and results were analyzed. Results were as follows : 1. As the intrapreparation distance, hydrophilic addition-cured silicone had the smallest change and condensation-cured silicone had the largest one. 2. As the lower base diameter, traditional addition-cured silicone had the smallest change and polyether had the largest one. 3. As the height, traditional addition-cured silicone had the smallest change and polyether had the largest one. 4. As the contact angle, polyether had the smallest change and condensation-cured silicone had the largest one.

  • PDF

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

Gait Stability in K-pop Professional Dancers

  • Jang, Young Kwan;Hong, Su Yeon;Jang, Inyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.377-382
    • /
    • 2016
  • Objective: The purpose of this study was to provide data on gait characteristics of K-pop professional dancers. Method: Participants were divided into four groups: male dancers (n=10, age: $28.2{\pm}3.4years$, height: $175{\pm}6cm$, weight: $68.9{\pm}5.6kg$), female dancers (n=10, age: $26.7{\pm}3.1years$, height: $162{\pm}4cm$, weight: $52.1{\pm}3.7kg$), non-dancer males (n=10, age: $25.2{\pm}2.6years$, height: $171{\pm}6cm$, weight: $66.4{\pm}5.3kg$), or non-dancer females (n=10, age: $26.2{\pm}3.0years$, height: $161{\pm}5cm$, weight: $56.4{\pm}6.7kg$). Twelve infrared cameras (Qualisys, Oqus 500, Sweden, 150 Hz.) were used to capture three-dimensional motion data. Gait motion data of professional dancers and ordinary persons were obtained. Results: K-pop dancers' dynamic stability during the female toe off event and the male heel contact event was better compared with that of ordinary persons in the front-rear direction. In addition, the results showed a significant difference in the margin of stability (MoS). However, the medial-lateral direction of both female and male dancers during heel contact and the toe off event was more stable compared with ordinary person, who exhibited an increased MoS than did the dancers. Conclusion: This study aimed to investigate the gait characteristics of K-pop professional dancers in comparison with ordinary persons using gait parameters and MoS. The stability of K-pop professional dancers' dynamic gait in the front-rear direction was better than that in the medial-lateral direction. Therefore, further studies in which the dance movements of K-pop dancers are sub-divided and analyzed will be necessary to reduce related injury.

Improvement on the Stability of Amorphous Indium Gallium Zinc Oxide Thin Film Transistors Using Amorphous Oxide Multilayer Source/Drain Electrodes

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.143-145
    • /
    • 2016
  • In order to find suitable source and drain (S/D) electrodes for amorphous InGaZnO thin film transistors (a-IGZO TFTs), the specific contact resistance of interface between the channel layers and various S/D electrodes, such as Ti/Au, a-IZO and multilayer of a-IGZO/Ag/a-IGZO, was investigated using the transmission line model. The a-IGZO TFTs with a-IGZO/Ag/a-IGZO of S/D electrodes had good performance and low contact resistance due to the homo-junction with channel layer. The stability was measured with different electrodes by a positive bias stress test. The result shows the a-IGZO TFTs with a-IGZO/Ag/a-IGZO electrodes were more stable than other devices.

A Study on the Fixation Characteristics of a Self-expansion Type ACL Fixation Device (자가 확장형 전방십자인대 고정장치의 고정 특성에 대한 연구)

  • Kim, Jong-Dae;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2009
  • This paper studied the influences of the main design parameter-the expansion angle and the material properties of the self-expansion anterior cruciate ligament fixation device on the contact condition with the bone and the initial stability of the device. Using finite element analysis, the stress distributions of the ring part of the device and the wall of the bone tunnel were calculated. And the micro-migration of the device by the pull-out force was calculated. From the analysis results, it was found that when designing the self-expansion type anterior cruciate ligament fixation device, it is desirable to use the material having higher Young's modulus and to design the fixation device that all wedges uniformly maintain contact with bone to obtain initial stability after operation.

  • PDF