• 제목/요약/키워드: Contact Pressure Sensor

검색결과 94건 처리시간 0.032초

혈압 측정을 위한 외팔보형 접촉힘 센서 어레이 (A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement)

  • 이병렬;정진우;전국진
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.

사출금형 버 발생 방지를 위한 형합면압 측정에 관한 연구 (Study on the Pressure Measurement at Parting Surface to Prevent Flashing in Injection Molds)

  • 최재혁;최순호;태준성;박형필;이병옥
    • 소성∙가공
    • /
    • 제20권1호
    • /
    • pp.73-78
    • /
    • 2011
  • The flashing reduces the part quality and the productivity of the molding process. We developed a contact pressure sensor to detect the flashing immediately. The performance of the sensor was analyzed in a simple 2D simulation. The sensor was applied to an automotive bumper mold with cavity pressure sensors. It showed sensitive output signal for the mold response by the cavity pressure change. It was confirmed that the flashing at the gate area occurred in the filling stage by the pressure increase due to growth of the melt flow length. The sensor output was correlated with the cavity pressure sensor output.

표면 가공형 캐비티 압력센서를 이용하여 비전도성 물질용 패키지 기술에 전기적 제어방식 연구 (The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor)

  • 이선종;우종창
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.350-354
    • /
    • 2020
  • In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.

CNG 탱크 내 연료량 계측을 위한 송·수신 초음파 센서의 접촉면 변경에 따른 수신 감도 분석 (Analysis of Receiving sensitivity according to Contact Surface Change of Transmit-Receiver Ultrasonic Sensor for Fuel Level Measurement in CNG Tank)

  • 김남욱;임석연;최두석
    • 한국융합학회논문지
    • /
    • 제9권4호
    • /
    • pp.137-142
    • /
    • 2018
  • 본 연구는 송 수신 초음파 센서를 이용하여 CNG 탱크에서의 정밀한 연료량을 측정하기 위한 기초 연구로써 탱크내부 압력 및 초음파 센서의 접촉면 변경에 따른 수신감도를 분석하였다. 실험은 탱크와 센서의 접촉면을 점, 선, 면의 3가지 타입으로 변경하고 탱크 내부의 압력을 0 bar 부터 5 bar까지 1 bar 간격으로 충전하면서 측정을 진행하였다. 실험결과 탱크내부의 압력이 증가함에 따라 초음파 센서의 수신신호 값이 감소하는 경향을 확인할 수 있었다. 또한 탱크와 센서의 접촉면적이 증가할수록 수신 신호 값은 증가하지만, 노이즈 또한 증가하는 것을 확인 할 수 있었다. 이와 같은 실험 결과 초음파의 투과 특성을 이용하여 탱크내부의 기체 연료량을 측정할 수 있을 것으로 판단되며, 센서의 접촉면 변경을 통해 정밀성을 향상시킬 수 있을 것으로 판단된다.

압력분포 측정용 시스템 개발 및 응용 (Development and Application of System for Pressure Distribution Measurement)

  • 김용환;박성하
    • 한국자동차공학회논문집
    • /
    • 제11권6호
    • /
    • pp.134-140
    • /
    • 2003
  • The film sensor is used for measuring pressure distribution at planar area, especially at a small space or gap. The present paper deals with the development of film type sensors and system for pressure distribution measuring. The developed system is consist of (1)film sensor with 40/sup */40 array, (2)PCI interface card with maximum sampling rate of 100㎐, and (3)software for data processing and real-time display. The contact pressure test of wiper blade and front glass of vehicle was performed with wiper blade by 40cm. Generally spring force of wiper arm is designed at 0.7∼1kN. Test results of total force was 9.4N and 7.1N in each driver and passenger toward. The paper suggested possibility for base definition in wiper design. A windshield wiper blade experiment revealed that the system successfully measured the contact force distribution during static state, showing the usefulness of the developed system.

Triboelectrification based Multifunctional Tactile Sensors

  • Park, Hyosik;Kim, Jeongeun;Lee, Ju-Hyuck
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.139-144
    • /
    • 2022
  • Advanced tactile sensors are receiving significant attention in various industries such as extended reality, electronic skin, organic user interfaces, and robotics. The capabilities of advanced tactile sensors require a variety of functions, including position sensing, pressure sensing, and material recognition. Moreover, they should comsume less power and be bio-friendly with human contact. Recently, a tactile sensor based on the triboelectrification effect was developed. Triboelectric tactile sensors have the advantages of wide material availability, simple structure, and low manufacturing cost. Because they generate electricity by contact, they have low power consumption compared to conventional tactile sensors such as capacitive and piezoresistive. Furthermore, they have the ability to recognize the contact material as well as execute position and pressure sensing functions using the triboelectrification effect. The aim of this study is to introduce the progress of research on triboelectrification-based tactile sensors with various functions such as position sensing, pressure sensing and contact material recognition.

Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석 (Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator)

  • 이문규;김종민;김동민;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.363-367
    • /
    • 2003
  • 인공무릎관절의 수명에 직접적인 영향을 주는 인자는 접촉면에 대한 접촉면적과 압력분포이다 따라서. 이에 대한 실험적인 평가가 필요하였고 knee simulator 혹은 K-scan sensor를 포함한 시스템과 같은 많은 연구가 진행되어 왔다. 그러나 지금까지 보행주기에 따른 연속적인 인공관절 운동에 대한 접촉면의 압력분포를 실시간으로 분석한 연구는 미흡하다 따라서 본 연구의 목적은 보행주기를 모사하는 simulator와 I-scan을 이용하여 연속적인 동작에 따른 접촉면의 압력분포를 분석함에 있다. 본 연구의 목적을 이루기 위해서 생체내 인공관절 환경을 정확히 표현할 수 있는 knee simulator를 제작하였다. 네 방향의 자유도를 갖고 있는 본 simulator는 soft tissue의 기능을 포함하고 있고 PC Program을 통하여 압축하중과 femoral component의 굴곡각을 조절할 수 있다. 본 시스템의 I-scan sensor는 보행주기에 따른 압력분포를 분석할 수 있다. 보행주기에 대한 압력분포는 압축하중곡선에 따라 주요하게 변화함을 알 수 있고 운동성에 영향을 쿠는 압력중심의 위치도 변한다는 것을 알 수 있다. 따라서 본 연구에서 제작한 knee simulator는 보행주기 같은 특정의 운동정보를 이용하여 접촉면의 압력분포 및 운동성 같은 기계적 성능을 평가할 수 있고 형상 설계를 위한 기초 자료를 제공할 수 있다.

분포형 유연촉각센서 (Distributed Flexible Tactile Sensor)

  • 유기호;윤명종
    • 제어로봇시스템학회논문지
    • /
    • 제10권1호
    • /
    • pp.60-65
    • /
    • 2004
  • A flexible tactile sensor away with 8 H 8 tactile elements is designed and fabricated. The material of the sensor is PVDF(polyvinylidene fluoride) film and flexible circuitry is used in the fabrication fur the flexibility of the sensor The experimental results on static and dynamic properties of the sensor are obtained and examined. The signals of a contact pressure to the sensor are sensed and processed in the DSP system in which the signals are digitalized and filtered. The processed signals of the sensor outputs are visualized in a personal computer for illustrating the shape and force distribution of a contact object. The reasonable performance for the detection of contact state is verified through sensing examples.

하퇴 의지 사용자의 족저압 분포 특성에 관한 연구 (A Study of Characteristics of Foot Pressure Distribution in Trans-tibial Amputee Subjects)

  • 김장환;신헌석
    • 한국전문물리치료학회지
    • /
    • 제8권3호
    • /
    • pp.1-10
    • /
    • 2001
  • The purpose of this study was to compare the static pressure, dynamic pressure, dynamic pressure-time integral, relative impulse, and contact time between the sound lower limb and amputated lower limb in trans-tibial amputee subjects using Parotec system. Seventeen trans-tibial amputee subjects wearing endoskeletal trans-tibial prosthesis voluntarily participated in this study. The results were as follows: 1) In static standing condition, there were significantly higher static pressure in sound lower limb insole sensor of 10, 14, 15, 18, 19, 23, and 24 and in amputated lower limb insole sensor of 9, 12, and 16 (p<.05). 2) In dynamic gait condition, there were significantly higher dynamic pressure in sound lower limb insole sensor of 2, 18, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, 14, 15, and 16 (p<.05). 3) In dynamic gait condition, there were significantly higher pressure-time integral in sound lower limb insole sensor of 2, 4, 18, 19, 20, 21, 23, and 24 and in amputated lower limb insole sensor of 5, 11, 12, and 15 (p<.05). 4) In dynamic gait condition, there were significantly higher relative impulse in sound lower limb insole sensor of 18, 19, 20, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, and 15 (p<.05). 5) In dynamic gait condition, there was significantly higher percentage of contact time in push off phase of sound lower limb and in support phase of amputated lower limb (p<.05). These results suggest that trans-tibial amputee subjects had characteristics of shortened push off phase due to unutilized forefoot and of lengthened support phase with higher pressure in the midfoot.

  • PDF