• 제목/요약/키워드: Contact Position

검색결과 663건 처리시간 0.03초

중심교합위와 후방교합위 간의 편위와 습관성 하악개폐운동과의 관계에 관한 연구 (A Study on the Relationship between the Deviation of the Intercuspal Position from the Retruded Contact Position and the Habitual Mandibular Closing and Opening Movements)

  • 송덕영;이승우
    • Journal of Oral Medicine and Pain
    • /
    • 제9권1호
    • /
    • pp.77-92
    • /
    • 1984
  • The purpose of this study was to investigate the relationship between the mandibular positions and the habitual mandibular opening and closing movements in normal subject using the newly developed electric mandibular movement analyzing device(Saphon Visi-Trainer C-II.Tokyo Shizaisha Inc. Tokyo, Japan) One of the cause of the temporomandibular joint dysfunction has been considered abnormal mandibular positions especially the abnormal deviation between intercuspal position from retruded contact position. The subjects in this study were consisted of 55 young adults in 20 decade who had normal occlusion, no prosthodontic restorations and no history of disturbance or pain on temporomandibular joint and masticatory muscles. The results were as follows : 1. The deviations of intercuspal position from retruded contact position were 0.23mm in frontal view and 1.02mm in sagirral view. 2. The larger the deviation of intercuspal position from the retruded contact position, the higher the proportion of uncoincidence of the habitual nandibular closing and opening trajectories was, and the proportion was higher in sagittal view than frontal view, 10mm opening than 5mm opening. 3. Correlation between the deviation of intercuspal position from retruded contact position and uncoincidence rate of the habitual mandibular closing and opening trajectories was higher in frontal view than sagittal view.

  • PDF

정상교합인의 두부위치변화에 따른 교합접촉점의 변화에 관한 연구 (A STUDY OF OCCLUSAL CONTACT VARIATON DUE TO CHANGE IN EACH HEAD POSITION IN NORMAL OCCLUSION)

  • 최희철;이성복;최대균;박남수
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.769-779
    • /
    • 1995
  • The understanding the nature of occlusal tooth contacts of natural dentition is important for correct diagnosis and treatment of diseases developed in stomatognatic system. Several investigator have studied the distribution of tooth contacts in maximum intercuspation and have repored contact locations with respect to the tooth position. However, there are few report the variation of the occlusal contact point with change in each head position. This study analysed the number of occlusal contact point with change in each head position. 30 subject(male 17, female 13), who ahad natural occlusion and no symptoms of temporomandibular disorder, were selected. The numbers and patterns of tooth contact were recorded by silicone bite registration on stone model at four different head positions with head anguration gauge(from the supine to the upright position). The results obtained were as follows : 1. The numbers of total occlusal contact point on teeth increased to average 25, 29, 35, 42 points as head angulation was changed from the supine to the upright position against the ala-tragus line, and there was significant difference(P<0.05). 2. In the 19 subject(65%)of total 30 subject, the perforated point of the silicone bite indicated that the locus for the prime contact point moved mesially as the head angulation was changed from the supine to the upright position. 3. On the basis of the fact that the anterior occlusal contact point increase as head angulation changed from the supine to the upright position, we could find that the mandibular position is moved anteriorly.

  • PDF

구와 원환체를 이용한 에어백의 모델링 및 비정상위치시의 승객 거동 해석 (A New Airbag Modeling Using a Sphere and a Torus and the Occupant Analysis in the Out-of-position)

  • 임재문;김창환;박경진
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.96-109
    • /
    • 1996
  • The airbag system is known to be extremely efficient for the protection in an automobile crash. The performance of the airbag system is evaluated by real tests. However, the test is very difficult and expensive. Therefore, the computational simulations are carried out with low cost. The airbag analysis is included in the anlysis of the full-car crashworthiness. The behavior of the airbag can be predicted by a thermodynamic analysis. The contact force between the occupant and the airbag is calculated from the contact volume and the pressure in the airbag. The injury rate is evaluated from the contact force and the acceleration of dummies. So far, the contact is defined after the airgag is fully inflated. In many cases, the occupant is seated in the out-of-position and the contact can happen during the inflation process. A new algorithm has been developed for the out-of-position. To describe the inflation process precisely, the airbag is defined by a sphere and a torus. The injury is evaluated for the contact happened at any time. The developed algorithm is coded and interfaced with an existing software in the public domain. The full-car modeling is adopted from the previous study which is tuned for the regular position and real tests. Numerical experimentation have been carried out with a couple of dummies in the out-of-position and the injury processes are analyzed.

  • PDF

3차원 접촉면의 인식 및 위치의 결정의 위한 광촉각센서와 역각센서의 다중센서시스템 (Multisensor System Integrating Optical Tactile and F/T Sensors for Determination of Type and Position of 3D Contact Surface)

  • 한헌수
    • 전자공학회논문지B
    • /
    • 제33B권2호
    • /
    • pp.10-19
    • /
    • 1996
  • This paper presents a finger-shaped multisensor system which can measure the tyep and position of a target surface by contactl. The multi-sensor system consists of a sphere-shpaed optical tactile sensor located at the finger tip and a force/torque sensor located at the joint of a finger. The optial tactile sensor determines the type and position of the target surface using the shape and position of the CCD image of the touching area generated by a contact between the sensor and the taget surface. The force/torque sensor also determines the position and surface normal vector by applying the distributionof forces and torques t the contact point to the equations of finger shape. The measurements on the position and surface normal vector at a contact point obtined by two individual sensors are fused using a statistical method. The integrated sensor system has 0.8mm error in position measurement and 1.31$^{\circ}$ error in normal vector measurement. The developed sensor system has many applications, such as autonomous compliance control, automatic grasping and recognition, etc.

  • PDF

차륜 및 차축의 변형을 고려한 차륜-레일 접촉해석 (Wheel-Rail Contact Analysis considering the Deformation of Wheel and Axle)

  • 최하영;이동형;유원희;이종수
    • 한국정밀공학회지
    • /
    • 제27권8호
    • /
    • pp.20-27
    • /
    • 2010
  • A precise evaluation of the contact position and the distribution of contact pressure in a wheel-rail interface analysis is one of the most important procedures to predict fatigue life and wear of wheel and rail. This paper presents the analysis result of finite element method(FEM) to investigate how the deformation of a wheelset, which is the assembly of wheel and axle of a railroad vehicle, affect the contact analysis of wheel and rail. 3D-FEM was used to analyze three contact models; a model with only wheel, a model with wheelset, and a model with simplified wheel and rail geometry. The analysis result of the contact position and the distribution of contact pressure are discussed. It is shown that the analysis results of a model with wheelset represent largest value with respect to contact pressure and contact stress. Furthermore, it is found that the distribution of contact pressure and the contact position is highly affected by the deformation of wheel and axle. It is concluded that the deformation of axle should be considered to evaluate the exact contact parameters in a wheel-rail contact analysis.

Triboelectrification based Multifunctional Tactile Sensors

  • Park, Hyosik;Kim, Jeongeun;Lee, Ju-Hyuck
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.139-144
    • /
    • 2022
  • Advanced tactile sensors are receiving significant attention in various industries such as extended reality, electronic skin, organic user interfaces, and robotics. The capabilities of advanced tactile sensors require a variety of functions, including position sensing, pressure sensing, and material recognition. Moreover, they should comsume less power and be bio-friendly with human contact. Recently, a tactile sensor based on the triboelectrification effect was developed. Triboelectric tactile sensors have the advantages of wide material availability, simple structure, and low manufacturing cost. Because they generate electricity by contact, they have low power consumption compared to conventional tactile sensors such as capacitive and piezoresistive. Furthermore, they have the ability to recognize the contact material as well as execute position and pressure sensing functions using the triboelectrification effect. The aim of this study is to introduce the progress of research on triboelectrification-based tactile sensors with various functions such as position sensing, pressure sensing and contact material recognition.

PUMA형 로보트 머니플레이터의 강인한 위치/힘 혼합제어 (Robust Hybrid Position/Force Control of a PUMA-Like Robot Manipulator)

  • 박재욱;이건복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.575-578
    • /
    • 1995
  • In general, the control of robot manipulator is classified into position control and force control. Position controllers give adequate performance when a manipulator is following a trajectory through space and end-effector has no contact with environment. However for most tasks performed by robot manipulator in industry, contact is made between the end-effector and manipulator's environment, so position control may not suffice. The objective of this study is to control both position of a manipulator and the contact forces generated at the hand by using a conceptually simple control law. Position and force control problem is decoupled into subtasts via taskspace formulation and inverse dynamics. Then, the position controllers are designed for the task space variable which represent tangent motion and the forte controllers are designed for the lash space variables which represent normal force.

  • PDF

Evaluation of proximal contact strength by postural changes

  • Kim, Hee-Sun;Na, Hyun-Joon;Kim, Hee-Jung;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권3호
    • /
    • pp.118-123
    • /
    • 2009
  • STATEMENT OF PROBLEM. Proper proximal contact is important for maintaining and stabilizing the dental arch. However, the proximal contact strength (PCS) is not a constant value and can be affected by a variety of factors. PURPOSE. This study examined the influences of postural changes on the posterior PCS. MATERIAL AND METHODS. Twelve adults with a normal occlusion and had not undergone prosthetic treatment or proximal restoration were participated in this study. A metal strip was inserted into the proximal surface and removed at a constant velocity. The contact strength was measured in every contact point between canine to second molar in both arches. The PCSs were obtained initially in the upright position, secondly in the supine position and finally in the upright position again. All measurements were repeated after a 2 hour period. Statistical analysis was carried out using the Friedman test (P < .05). RESULTS. Generally, a decrease in PCS occurred when the posture was changed from the initial upright to supine position, while it increased when the posture was changed from the supine to upright position. A significant change was observed in all areas except for between the canine-first premolar in the maxilla and between the first molar-second molar in the mandible areas. CONCLUSION. The posterior PCS, which dentists generally believe to be a static feature of occlusion, is affected significantly by posture.

부스바 접점 가동시 접촉면에서 압점력 해석 (Analysis for Force Distribution on Surface Between Busbar Contacts)

  • 오연호;송기동;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

자세에 따른 골반경사운동이 편마비 환자의 발 접촉양상에 미치는 효과 (The Effect of Pelvic Tilt Exercise with Changing the Body Position on Foot Contact Pattern in Hemiplegic Patients)

  • 장상훈;박수진;김민희;김중휘;김진상
    • 대한물리의학회지
    • /
    • 제5권3호
    • /
    • pp.445-453
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of pelvic tilt exercise with changing the body position on foot contact pattern in the hemiplegic patients. Methods : Thirty seven hemiplegic patients were randomly divided 3 groups; control group (CG), sitting exercise group (SIEG) and standing exercise group (STEG). F-mat system and F-scan system were used for the measurement of foot contact pattern of hemiplegic side in walking. Data were analyzed statistically using paired t-test and one-way ANOVA. Results : The results were as follows : 1) Contact area of CG and SIEG were not significant difference in walking. Contact area of STEG was significant increased in walking. 2) Anteroposterior distance of COP of SIEG and STEG were significant increased in walking. Conclusion : These results suggest that pelvic tilt exercise in sitting and standing position are effective in the improvement of Anteroposterior distance of COP and gait stability are increased in only standing position.