• Title/Summary/Keyword: Contact Line

Search Result 843, Processing Time 0.025 seconds

Evaluation of the creep damage of the Type 316LN stainless steel by the ultrasonic wave velocity (초음파 속도를 이용한 Type 316LN 스테인리스 강의 크리프 손상 평가)

  • Yi Won;Noh Kyung-Yong;Yun Song-Nam;Kim Woo-Gon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.818-823
    • /
    • 2005
  • Creep damage is one of the mosl important characteristics for the stability of high temperature structures such as huge energy converting facilities. Creep failure of Type 316LN stainless steel is highly correlated to generation and growth of the voids. In this paper, in order to investigate the correlation of creep rupture time and ultrasonic parameters (group velocity, angular velocity), creep-damaged Type 316LN specimens and measurements for the ultrasonic parameters were made. However, bi-directional measurements were applied along the load direction and the perpendicular direction to the load line by means of the contact type probe of which the central frequencies are 10MHz, 15MHz and 20MHz. Analyzing the angular velocities of the ultrasonic signals obtained from the load direction, it was confirmed that the angular velocities were declined as the creep time passed when 15MHz and 20MHz probes were used. Also, the group velocities were declined for all three frequencies as the creep time increased. Thus, positive feasibility for the creep damage evaluation by means of the angular and group velocities was confirmed. Moreover, result of analysis for the ultrasonic signal which was obtained from the perpendicular direction upon the angular and group velocities indicated little variation for both of the angular and group velocities. Therefore, the creep damage is likely to represent anisotropic itself.

  • PDF

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Evaluation of Ice Adhesion Strength on the Oxidation of Transmission Line ACSR Cable (송전선로 ACSR 케이블의 산화에 따른 결빙 특성 평가)

  • Cho, Hui Jae;Kim, You Sub;Jung, Yong Chan;Lee, Soo Yeol
    • Korean Journal of Materials Research
    • /
    • v.29 no.6
    • /
    • pp.378-384
    • /
    • 2019
  • Ice accumulation on Aluminum Conductor Steel Reinforced(ACSR) cable during winter is an important matter in terms of safety, economy, and efficient power supply. In this work, the ice adhesion strengths of ACSR cable oxidized during different periods(7 years oxidized and 15 years oxidized) are evaluated. At first, a plate type dry oxidation standard specimen, whose surface characteristics are similar to those of ACSR cable, is prepared. Dry oxidation standard specimens are heat-treated at $500^{\circ}C$ for 20, 60, and 120 minutes in order to obtain different degrees of oxidation. After the dry oxidation, surface properties are analyzed using contact angle analyzer, atomic force microscopy, spectrophotometer, and gloss meter. The ice adhesion strengths are measured using an ice pull-off tester. Correlations between the surface properties and the ice adhesion strength are obtained through a regression analysis indicating a Boltzmann equation. It is revealed that the ice adhesion strength of 15-year oxidized ACSR cable is approximately 8 times higher than that of ACSR-bare.

Responsive Healthcare System for Posture Correction Using Webcam-Based Turtle Neck Syndrome Discrimination Algorithm (웹캠 기반 거북목 판별 알고리즘을 활용한 자세 교정 반응형 헬스케어 시스템)

  • Park, Soyeon;Ryoo, Seojin;Dong, Suh-Yeon
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.285-294
    • /
    • 2021
  • This study developed a responsive healthcare system that users can easily use in real life to prevent turtle neck syndrome by posture correction. We propose a system that naturally induces direct posture improvement by adjusting the height with a responsive cradle through a turtle neck discrimination algorithm detecting the turtle neck posture in real time using a webcam. The turtle neck algorithm was developed based on machine learning, using the points that the distance relationship between the jaw line and the shoulder varies depending on the posture. For the younger age group, which is particularly problematic due to the increase in the use of IT devices, image data in different situations according to the height and posture of the cradle was collected and learned as a support vector machine classifier. In addition, a height-adjustable cradle that can support a laptop has been created and expanded into a responsive cradle that can be controlled with software by interlocking with the Arduino. Therefore, this service enables posture correction of many modern people suffering from turtle neck syndrome and will become an essential platform in the increasing online environment in the non-contact era.

A Study on Non-face-to-face Educational Methods which can be used in Practical Subject of Game Production (게임제작 실습 교과목에서 활용할 수 있는 비대면 교육방법 연구)

  • Park, Sunha
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.1
    • /
    • pp.125-133
    • /
    • 2021
  • Due to Covid-19, the un-contact culture has affected society as a whole, and the methods of education conducted offline has been greatly affected. In the private education of preparing for university entrance, the public official examinations and certification acquisition, the method of online education has been shown to have positive effects. While private class and school class which have offered in off-line to cope with rapid changes caused various problems such as decline in quality for education. Due to the characteristic of design class, practical training is important. As interactive feedback between students and educators is more important than one-way of delivering knowledge while class is conducted in online, educators have a challenge when they prepare for class. This study handles the methods of online education for the purpose of practical education methods in university nowadays, Especially, the non-face-to-face education methods for game animation production. Based on this study, I propose an effective educational method with non-face-to-face class that allows students to be satisfied and increases their knowledge, beyond face-to-face class.

Design of Heavy Weight Door Hinge for Built-in Appliances (빌트인 가전기기용 고 중량 도어힌지의 설계에 관한 연구)

  • Choi, Seong-Dae;Byn, Yong-Kun;Kim, Gi-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.41-47
    • /
    • 2021
  • In this study, the hinges of heavy weight doors were designed and analyzed in line with the trend that built-in appliances are becoming larger and the weight of doors is also increasing. The main specification of the heavy weight door hinge is to allow the deflection at the end of the door to be less than 2 mm when opening and closing, including the automatic closing, slow closing, and closing force control functions. The structural analysis of the design mechanism, component design, and methods for improving the deflection are as follows: 1) Mechanism of the automatic closing function should sense automatically using the spring compression force at a specific angle by the contact between the cam and the cam module roller. 2) Through structural analysis, the maximum stress of the door was found in the link pin hole connected to the pin at each link. 3) Consequently, the pin holder was designed and applied, with little variance, but up to 93% of the specification limit.

Design and Implementation of Physical Computing Education Content based on Augmented Reality

  • Kim, So-Young;Jung, Eunmi;Kim, Heesun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.198-205
    • /
    • 2022
  • Along with a variety of coding education, physical computing education for controlling various sensors is being actively conducted for elementary, middle, and high school students in line with the era of the fourth industrial revolution. A problem with physical computing education using Arduino is pin connection errors between Arduino and various sensors. Most of the students who come into contact with the Arduino for the first time often do not know the purpose of the Arduino pin and the connection position of the pin. Also, hardware built with incorrect pin connections to the Arduino board often does not work properly. If this case continues, students will lose interest in coding education. Therefore, in this paper, we implemented an augmented reality application that informs the connection process of the Arduino board and the sensor during physical computing coding education using Arduino, and designed and implemented educational content for the Arduino pin position and connection process. First, we explain the role of the Arduino board and the sensor and the location of the pins. After that, the students run the educational augmented reality educational content using their smartphones and check the correct pin connection process between the Arduino and the sensor. In the physical computing education, augmented reality content is used to increase the understanding and immersion of the class. It is expected that the educational effect will also increase by inducing fun and interest in physical computing coding education.

Seismic response of single-arch large-span fabricated subway station structure

  • He, Huafei;Li, Zhaoping
    • Earthquakes and Structures
    • /
    • v.23 no.1
    • /
    • pp.101-113
    • /
    • 2022
  • A new type of fabricated subway station construction technology can effectively solve these problems. For a new type of metro structure form, it is necessary to clarify its mechanical properties, especially the seismic performance. A soil-structure elastoplastic finite element model is established to perform three-dimensional nonlinear dynamic time-history analysis based on the first fabricated station structure-Yuanjiadian station of Changchun Metro Line 2, China. Firstly, the nonlinear seismic response characteristics of the fabricated and cast-in-place subway stations under different seismic wave excitations are compared and analyzed. Then, a comprehensive analysis of several important parameters that may affect the seismic response of fabricated subway stations is given. The results show that the maximum plastic strain, the interlayer deformation, and the internal force of fabricated station structures are smaller than that of cast-in-place structure, which indicates that the fabricated station structure has good deformation coordination capability and mechanical properties. The seismic responses of fabricated stations were mainly affected by the soil-structure stiffness ratio, the soil inertia effect, and earthquake load conditions rarely mentioned in cast-in-place stations. The critical parameters have little effect on the interlayer deformation but significantly affect the joints' opening distance and contact stress, which can be used as the evaluation index of the seismic performance of fabricated station structures. The presented results can better understand the seismic responses and guide the seismic design of the fabricated station.

A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

  • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF

The Cytotoxicity and Effect on the Experimental Rabbit Cornea of Soft Contact Lens Multi-Purpose Solution (MPS) (콘택트렌즈용 다목적용액(MPS)의 세포증식저해 및 실험용 토끼 각막에 미치는 영향)

  • Koh, Eun-Gyeong;Chae, Soo-Chul;Park, Su-Kyoung;Kim, Deok-Song;Lee, Jong-Bin
    • Applied Microscopy
    • /
    • v.36 no.3
    • /
    • pp.141-153
    • /
    • 2006
  • The purpose of this study is to find out how soft contact lens multi-purpose solution (MPS), often used for medical treatment, effects the inhibition on cell growth and research the result of using MPS, suspected to demage eye cells, on rabbit eye's corneal epithelium and endothelium tissue. In this treatise, $ReNu^{(R)}$ (Baush & Lomb, USA), Opti-free $express^{(R)}$ (Alcon, USA), Free-sol $plus^{(R)}$ (Hanamedicon, Korea) had been selected among the MPS. After culturing L929 roil line, cell growth inhibition rate was measured by MTT assay, and by making Hematoxylin and Eosin stain specimen. the morphology was observed by optical microscope. In the In vivo experiment,9 white rabbit eyes (18 eyes) were classified into 3 groups. The experimental group is left eyes (9 eyes) of rabbit, and MPS were dropped; however. the control group, the right eyes (9 eyes), were only used a saline solution without preservatives. After the dropping within the period, the cornea surface of rabbit eyes were stained by Rose bengal and observed. To figure out the changes of the corneal epithelium and endothelium tissue scanning electron microscopy (SEM) has been used. As the result, the rate of cell growth inhibition was 54%. 73% and 36%, respectively. Morphological changes represented that the shape has been changed into oval or round shape and those are not considered as a common formation of L929 cell line. When it comes to staining Rose bengal, each experiment group was stained red which is not shown in controls. The polygonal mosaic pattern of a corneal epithelium was disturbed in the picture taken by SEM; furthermore, the shape of the corneal endothelium was irregular. In conclusion, as we consider antimicrobial effect and the safety on living cells, it is necessary that we should improve concentration of preservatives and study continuously to develop a new preservatives without a toxic effect on the cornea surface.