• Title/Summary/Keyword: Consumption Rate

Search Result 3,217, Processing Time 0.031 seconds

A Study on the Energy Saving Methods of a House by Passive System (건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구)

  • 김용식
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

Studies on the Effect of 'Gal Geun Tang' upon Stress Resistance of Rats (갈근탕(葛根湯) 투여가 흰 쥐의 스트레스 저항 반응에 미치는 영향에 관한 연구)

  • Kwon, Chang-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.5 no.4
    • /
    • pp.217-222
    • /
    • 1974
  • Oxygen consumption rate has been determined to study the effect of 'Gal Geun Tang' upon stress resistance of rats. The oxygen consumption rate of liver tissue increased slightly when normal rats were given the Gal Geun Tang infusion only. When rats were given the infusion after an injection of typhoid vaccine, the elevated boby temperature and oxygen consumption rate due to typhoid vaccine fell to normal level. From this result, it is concluded that 'Gal Geun Tang' has a function that may normalize abnormally strained liver metabolism. Oxygen consumption rate of the rats significantly increased when rats were exposed to cold condition. However, under the same condition it rather maintained the normal consumption rate when the rats were given previously "Gal Geun Tang". It is suggested that 'Gal Geun Tang' has an effects that impairs the immune response from cold stress. The rats that were given Cinnamomi Ramulus('Ge Ji Tang') showed less effect than the group of 'Gal Geun Tang'.

  • PDF

A Study on the pattern of tenant layout in the Urban Entertainment Center (도심 엔터테인먼트 쇼핑센터(UEC)의 테넌트 배치 형태에 관한 연구)

  • Lee, Hyunsoo;Oh, Jung-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.233-242
    • /
    • 2012
  • The purpose of this study is to analyze the pattern of tenant layout for selected cases of five different Urban Entertainment Center(UEC) in Seoul. This research deals with the process of gaining tenant layout pattern of 40 different types. It is composed of three combination unit with tenants of the same or different consumption mode, which is divided into four different functions of retail, entertainment, dining, and service. Then, every tenant of research cases is classified as one of the fabric type, and the data is analyzed to gain its frequency rate with SPSS 14.0 program. The following is the overall explanation of the result for this research. The frequency of tenant layout pattern between the same consumption mode shows the high rate when compared to the other patterns with different consumption mode. For example, the frequency rate of tenant layout pattern which retail and dining consumption mode are placed side by side like RRR and DDD is high. Interestingly, the frequency rate of RRR type of tenant layout pattern that sells the similar products shows especially high level. It can provide the effective environment for shoppers to compare retail goods in many different stores as producing synergic effects when they are located near each other, so this strategy should be considered when planning tenants in UEC environment. Moreover, in case of dining tenants, when they are clustered together in the UEC environment it can play a role as an anchor tenant. Tenant layout pattern of dining-retail and dining-service consumption mode shows the high frequency rate than other layout pattern with other consumption mode. Besides, entertainment consumption tenants combined with dining or retail tenants show the high frequency rate when compared to the pattern combined with service consumption mode.

  • PDF

Physiological analysis of mountain climbing exercise (등산운동의 생리학적 분석)

  • Kim, Wan-Tai;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.15-27
    • /
    • 1971
  • Physiological analysis of the physical exercise was made on 9 subjects performing mountain climbing. The course between two points (256 and 516 meters altitude) was 1,300 meters in distance and difference of vertical height was 260 meters making the mean grade of 20%. In the field, the heart rates during uphill or downhill walk were recorded by EKG radio-telemetry. In the laboratory, oxygen consumption was obtained by the recorded heart rates, using individual heart rate vs oxygen consumption diagram obtained by treadmill test. the following results were obtained. 1. Uphill walk time was 36.5 minutes, and during this period the mean heart rate was 149.0 heats/min and peak heart rate was 169.2 beats/min. The total heart beats during the uphill walk was 5.433 beats. 2. The ratio of individual mean heart rate during the uphill walk to the maximal heart rate distributed between 66.6% and 98.3%, and the mean of the total group was 83.1%. The ratio of peak heart rate of uphill walk to the maximal heart rate was 94.5% in the group. Thus uphill walk of a 20% grade mountain course was an exhaustive exercise. 3. Oxygen consumption during uphill walk was 2.22 l/min (ranged between 1.79 and 2.70 l/min) and the ratio of this to the resting oxygen consumption was 8.31. The peak value of oxygen consumption during uphill walk was 2.73 l/min and the ratio of this to the resting oxygen consumption was 10.39. 4. Energy expenditure during uphill walk showed a mean of 11.1 kcal/min and the peak expenditure rate was 13.6 kcal/min. The total energy expenditure during 36.5 minutes of uphill walk was 396 kcal. 5. In downhill walk, the time was 31.7 minutes, mean heart rate was 118.4 (ranged between 100.1 and 142.7) beats/min, and the peak heart rate was only 129.4 beats/min. The ratio of mean heart rate to the maximal heart rate was 66.3%. Total heart beats during downhill walk was 3,710 beats. The ratio of downhill oxygen consumption to the resting consumption was 5.70. The rate of energy expenditure was 7.5 kcal/min, and the total onery expenditure during the 31.7 minutes of downhill walk was 228 kcal. 6. The effect of training was manifest in the uphill walk and not in the downhill walk. After training in mountain course walk, i) the uphill time was shortened, ii) mean heart rate increased, iii) time vs heart rate curve became smooth and showed less frequent zig-zag, i.e., the depth of trough on the curve decreased and the magnitude was less than 10 beats. In non-trained subject the depth of trough on the curve was greater than 50 beats and appeared more frequently. 7. Mountain climbing is a good health promotion exercise. For the promotion of health the reasonable amount of uphill mountain walk exercise in a 20% grade course is a walk for 40 or 50 minutes duration once a week.

  • PDF

Effect of Amino Acids on Oxygen Consumption of the Mang-Kong Frog (Gallula tornieri VOGT) Liver (맹꽁이 간의 산소소비량에 미치는 수종 아미노산의 영향)

  • 박상윤;최순영
    • The Korean Journal of Zoology
    • /
    • v.4 no.2
    • /
    • pp.20-24
    • /
    • 1961
  • The present experiment was conducted to investigate the rate of oxygen consumption in relation to the several amino acids in the Mang-Kong frog ,Gallula tornieri VOGT. 1. When the liver tissue was suspended in the Ringer's solution (0.85% NaCl), the amount of oxygen consumption per hour was 0.043$\mu$l/mg , whereas when it was suspended in M/15, pH 5.8 phosphate buffer the oxygen consumption reached 0.93$\mu$l/mg. 2. When 0.5ml of 1% alanine and 0.5ml of 0.5% arginine were used as respiratory material the amount of oxygen consumption increased remarkably, while on the other hand glycine showed little influence on the amount of oxygen consumption. 3. When 0.5ml of 0.1% , 0.5% alanine-arginine mixture, 0.5ml of 0.1% , 0.5% alanine-glycine mixture and 0.5ml of 1 % arginine-glycine were added the oxygen consumption in the liver tissue increased somewhat in comparison to the case in which single amino acid was used. 4. Glycine appeared to have influence on the respiration of the liver tissue but the amount of oxygen consumption increased as the concentration of arginine-glycine mixture increased, whereas the rate of oxygen consumption increased remarkably as alaninie-glycine mixture decreased. It was evidenced that in the combination of alanine-arginine the rate of oxygen consumption increased as the concentration of the mixture decreased and vice versa.

  • PDF

Changes of Survival, Growth and Oxygen Consumption in the Oliver Flounder, Paralichthys olivaceus Exposed to TBT (TBT의 노출에 따른 넙치, Paralichthys olivaceus의 생존, 성장 및 산소소비의 변화)

  • 강주찬;황운기;지정훈
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2002
  • This study was carried out to examine the effects of bis (tribytyltin)oxide (TBT), endocrine disrupting compounds (EDCs). on the changes of survival, growth and oxygen consumption rate in the oliver flounder, Paralichthys olivaceus. Oliver Flounders were exposed to sublethal concentration of TBT (0, 1.67, 3.20, 6.30 and 12.50 $\mu\textrm{g}$/L) during 6 weeks. Survival rate was decreased in a concentration and exposure period-dependent way and suddenly the reduction of more than 20% occurred at TBT concentration greater than 3.20 $\mu\textrm{g}$/L. after exposure 6 weeks. Growth rate and feed efficiency significantly decreased at concentration greater than 3.20 $\mu\textrm{g}$/L. Oxygen consumption rate was also decreased in a concentration-dependent way and significantly decreased to 17,48 and 67% than that of the control at the TBT concentration of 3.20, 6.32 and 12.50 $\mu\textrm{g}$/L, respectively. This study revealed that high TBT concentration ($\geq$3.20 $\mu\textrm{g}$/L) reduced growth and oxygen consumption rates of the juvenile oliver flounder suggesting potential influence on the natural mortality of Paralichthys olivaceus in the coastal areas.

Verification and Development of Simulation Model for Fuel Consumption Calculation between ICEV and PHEV (자동차 동력원별(ICEV, PHEV) 연비산출 모델개발 및 이의 검증)

  • Kim, J.W.;Park, J.M.;Kim, T.K.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.47-54
    • /
    • 2017
  • $CO_2$ emission regulation will be prescribed and main issue in automotive industry. Mostly, vehicle's fuel efficiency deeply related to $CO_2$ emission is regulated by qualified driving test cycle by using chassis dynamometer and exhaust gas analyser. But, real driving fuel consumption rate depends so much on the individual usage profile and where it is being driven: city traffic, road conditions. In this study, vehicle model of fuel consumption rate for ICEV and PHEV was developed through co-simulation with CRUISE model and Simulink based on driving control model. The simulation results of fuel consumption rate were analysed with on-road vehicle data and compared with its official level.

Minimum Energy-per-Bit Wireless Multi-Hop Networks with Spatial Reuse

  • Bae, Chang-Hun;Stark, Wayne E.
    • Journal of Communications and Networks
    • /
    • v.12 no.2
    • /
    • pp.103-113
    • /
    • 2010
  • In this paper, a tradeoff between the total energy consumption-per-bit and the end-to-end rate under spatial reuse in wireless multi-hop network is developed and analyzed. The end-to-end rate of the network is the number of information bits transmitted (end-to-end) per channel use by any node in the network that is forwarding the data. In order to increase the bandwidth efficiency, spatial reuse is considered whereby simultaneous relay transmissions are allowed provided there is a minimum separation between such transmitters. The total energy consumption-per-bit includes the energy transmitted and the energy consumed by the receiver to process (demodulate and decoder) the received signal. The total energy consumption-per-bit is normalized by the distance between a source-destination pair in order to be consistent with a direct (single-hop) communication network. Lower bounds on this energy-bandwidth tradeoff are analyzed using convex optimization methods. For a given location of relays, it is shown that the total energy consumption-per-bit is minimized by optimally selecting the end-to-end rate. It is also demonstrated that spatial reuse can improve the bandwidth efficiency for a given total energy consumption-per-bit. However, at the rate that minimizes the total energy consumption-per-bit, spatial reuse does not provide lower energy consumption-per-bit compared to the case without spatial reuse. This is because spatial reuse requires more receiver energy consumption at a given end-to-end rate. Such degraded energy efficiency can be compensated by varying the minimum separation of hops between simultaneous transmitters. In the case of equi-spaced relays, analytical results for the energy-bandwidth tradeoff are provided and it is shown that the minimum energy consumption-per-bit decreases linearly with the end-to-end distance.

Chronic Toxicity of Mercury on Survival , Growth and Oxygen Consumption in the Juvenile Olive Flounder Paralichthys olivaceus (넙치,Paralichthys olivaceus 치어의 생존, 성장 및 산소소비에 미치는 수은의 만성적 독성)

  • Kang, Ju-Chan;Hwang, Un-Gi;Jee, Jung-Hoon;Kim, Seong-Gil;Kim, Jae-Won
    • Journal of fish pathology
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2002
  • Effect of mercury (Hg) toxicity on survival, growth, feed efficiency and oxygen consumption were examined in the juvenile olive flounder. Paralichthys olivaceus. Fishes were exposed to sublethal concentrations of Hg ranging from 0 to 0.13mg/L for 6 weeks. Hg reduced survival rate in a concentration and exposure period-dependent way and suddenly reduction occurred at Hg concentrations greater than 0.05mg/L after 6 weeks. Growth rate and feed efficiency also significantly decreased at greater than 0.028 and 0.05 mg/L respectively. Oxygen consumption rate was significantly decreased to 25 and 32% than that of the control at the Hg concentration of 0.05 and 0.13 mg/L respectively. These results suggest that Hg toxicity inhibit physiological function including growth, feed efficiency and oxygen consumption in the juvenile olive flounder, resulting in survival failure at high concentration.

Ventilation Rate Impact on Heating and Cooling Energy Consumption in Residential Buildings : Concentrated on a Detached House in Cold and Hot/Humid Climatic Zones of USA (환기량의 주거건물 냉난방에너지 소비에 대한 영향 : 미국 한랭기후 및 고온다습기후의 단독주택을 중심으로)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.747-753
    • /
    • 2011
  • The purpose of this study was to quantify the impact of the ventilation rate on heating and cooling energy consumption in a detached house. For it, a series of simulations for the application of the diverse ventilation rate (ACH) were computationally conducted for a prototypical detached residential building in the cold climate (Detroit, Michigan) and hot/humid climate (Miami, Florida) of USA. Analysis revealed that ventilation is a significant heat losing source in the cold climate; thus, the higher ventilation rate significantly increases the heating energy consumption and energy cost in the cold climate; while the impact on energy increase for heating and cooling energy consumption is similar in hot/humid climate with less significancy compared to cold climate. The research outcome of this study could be a fundamental data for determining the optimal ventilation rate in terms of indoor air quality, but also building energy performance well.