• Title/Summary/Keyword: Consumed-Power

Search Result 383, Processing Time 0.022 seconds

Heating Performance of Geothermal Heat Pump System Applied in Cold Climate Region(Mongolia) (한랭지(몽골) 지열 히트펌프 시스템의 난방 성능 분석)

  • Sohn, Byonghu;Choi, Jae Ho;Min, Kyung Chon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Geothermal heat pump (GHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. These systems use the ground as a heat source in heating mode operation and a heat sink in cooling mode operation. The aim of this study is to evaluate the heating performance of the GHP system for a residential building ($420m^2$) in Ulaanbaatar, Mongolia. In order to demonstrate the feasibility of a sustainable performance of this system, we installed the water-to-water geothermal heat pump with ten vertical ground heat exchangers and measured operation parameters from October 19, 2013 to March 26, 2014. The results showed that the entering source temperature of brine from the ground heat exchangers was in a range of the design target temperature of $-10^{\circ}C$ for heating. For total values of the representative results, the ground heat exchangers extracted heat of 53.51 MWh from the ground. In addition, the GHP system supplied heat of 83.55 MWh to the building and consumed power of 30.27 MWh. Consequently, the average heating seasonal performance factor ($SPF_h$) of the overall system was evaluated to be 2.76 during the measurement period of the heating season.

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.

Application of an Infrared Drying to Drying Process for Red Pepper (고추의 건조(乾燥) 공정(工程)에서 적외선(赤外線) 건조법(乾燥法)의 활용(活用)에 관한 연구(硏究))

  • Koh, H.K.;Cho, Y.J.;Kang, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.3
    • /
    • pp.230-243
    • /
    • 1990
  • This study was conducted to investigate the possibility of application of an infrared drying to drying process for red pepper. The performance of seramic heaters and the variation of temperature and moisture content of red pepper were analyzed during an infrared drying of red peppers. Also, the quality of dried red pepper was analyzed. The following results were obtained from this study. 1. The surface temperature of infrared heaters and the rising time required for steady state were mainly affected by electrical power consumed. 2. The heat energy required for heating red pepper was proposed to be calculated by the equation in terms of enthalpy of air and net heat flux by infrared heater in a drying chamber. The statistical model for net heat flux was developed. 3. The performance of the infrared heater used for heating red pepper was much affected by the distance of radiation, and the difference of temperatures appeared between the radiated surface and the inside of red pepper. 4. Electrical capacity of the infrared heater had a significant effect on the heating of red pepper. However, the effect of shape of heater on heating was not significant. 5. The variation of temperature of red pepper largely appeared in the range of 30 to 60% (db) in moisture content. The temperature of red pepper was almost constant at low moisture content. 6. The temperature of red pepper and heating time had significant effects on the quality for radiant heating. 7. When the electrical capacity of infrared heater and the distance of radiation are carefully designed in a dryer with the insulated drying chamber, infrared drying might be very effective in red pepper drying.

  • PDF

Study on The Supplying effect of Gas Air Conditioning Systems (가스냉방 보급효과에 대한 연구)

  • Han, J.O.;Chae, J.M.;Choi, K.S.;Hong, S.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.19-25
    • /
    • 2011
  • Generally, the generation methods of cooling energy are electric air conditioning (EAC) and gas air conditioning (GAC). The EAC system is caused by increasing peak power during summer. Because the electric energy has a characteristic of non-storage, the peak electric load has been issued social problem annually whether the facility to supply is enough or not. Another way to supply cooling energy, GAC system is worked by gas energy. The absorption chiller and gas engine heat pump have been commercialized for cooling. However, the total capacity of GAC is much less than EAC and it almost depends on EAC for small market. This paper described the status of cooling energy consumption in domestic and expected the cooling energy to be consumed by electric and gas energy up to 2024 year. And also the benefit of GAC was analyzed with the case of its expansion and it was aimed to give background to fit the GAC policy.

Performance Comparison of Heat Transfer Plates for Cooling Tower Air Heater Through Numerical Analysis (냉각탑 공기가열기용 전열판의 수치해석적 성능 비교)

  • Lee, Eul-Jong;Kim, Jung-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5676-5683
    • /
    • 2012
  • In this study, numerical analysis was performed on three shapes of heat transfer plates (chevron, wave and dimple type), which are currently used as fillers of cooling towers. Results show that heat transfer rates per consumed power were larger for enhanced plates as compared with that of plain plate. Highest heat transfer coefficient was obtained for wave shape followed by chevron and dimple shape. For wave shape, cross corrugations induced significant mixing of fluids, which enhanced the heat transfer. Friction factor yielded a similar trend with the heat transfer coefficient. However, heat transfer rate and pressure drop per sheet was the largest for chevron shape, due to the largest heat transfer area per sheet.

Studies on Livestock Pollution Treatment and Energy Production (축산공해의 해결방안과 에너지 생산에 관한 연구)

  • 김창한;윤여창;최재용
    • Microbiology and Biotechnology Letters
    • /
    • v.9 no.4
    • /
    • pp.219-223
    • /
    • 1981
  • Experiments on methane gas digestion were conducted to prevent livestock pollution and develop substitute energy. When about 30(w/w)% of sludge was added to cow feces, pig feces, and poultry feces and digested at 37$^{\circ}C$ for 20 days, methane gas produced per Kg of organic matter for cow feces, pig feces, poultry feces was 131, 248 and 235 l, respectively. pH decreased slightly at first but increased gradually afterwards during digestion period. When 20, 30, and 40(w/w)% of sludge were added to the mixture of cow feces (300g) and water (200g), the volumes of gas produced were 6.1, 14.5 and 13.4 l, respectively. Volume of methane gas produced from the mixture of cow feces and saw dust was much more than that from the mixture of cow feces and rice polishings. The contents of N, K, P for digestion residues were sufficient to be utilized as a fertilizer. When methane gas digestion was carried out with cow feces in a submersible pump digester the volume of methane gas produced per Kg of organic matter was 188 l. The price of total methane gas produced at this digestion was similar to that of the electric power consumed.

  • PDF

An Energy Harvesting and Profiling System for Smart Video Devices (스마트 비디오 디바이스를 위한 에너지 하비스팅 및 프로파일링 시스템)

  • Kang, Doo-sik;Kim, Jun-sik;Park, Keon-woo;Lee, Myeong-jin
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.99-106
    • /
    • 2017
  • In this paper, an energy harvesting and profiling system is designed for smart video devices in internet of things environments without dedicated power source. The energy harvesting module provides the harvested energy from solar panel to the smart video device. The energy profiling module measures the battery outflow current and the battery voltage of the smart video device and the consumed energy of processes, and calculate the harvested energy from the energy harvesting module to the smart video device and the total energy consumption of the smart video device. The accuracy of the harvested energy measured by the device energy profiling module is validated by comparing with the calculated energy using the regional solar radiation provided by Korea Meteorological Administration. Energy harvesting data from the designed energy harvesting and profiling system can be used to design the perpetual operation of smart video devices or Internet of Things sensors.

Development of Wireless Data Transmission System for LPWA-based Industrial Sites (LPWA 기반 산업현장의 무선 데이터 전송 시스템 개발)

  • Kwon, Hyuk;Cho, Kyoung-Woo;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.1
    • /
    • pp.37-42
    • /
    • 2018
  • Recently, there have been many studies on the IoT environment in which the sensors attached to the equipment automatically transmit and process the site information in real time through the network to control the equipment. The core of such a system is a network for data transmission and reception, and a wired network with wide transmission distance is a priority. However, in the case of a wired network, there is a problem that the time and cost consumed to configure the communication is higher than that of the wireless. In this paper, we propose LPWA - based wireless data transmission system using LPWA and BLE communication to solve this problem. The proposed system collects data from equipment through BLE and transmits data to the server using LPWA. Experimental results show that the spreading factor of maximum length of LPWA is 8, and the minimum length is 9.

Development of Pilot Injection Plant for CO2 Underground Storage (이산화탄소 지중저장용 파일럿 주입플랜트 개발)

  • Yoon, Seok-Ho;Kim, Young;Lee, Jun-Ho;Lee, Kong-Hoon
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.42-45
    • /
    • 2013
  • The worldwide issue of greenhouse gas reduction has recently drawn great attention to carbon capture and storage(CCS). In this study, we developed a 10,000 ton/year pilot injection plant for geological storage of carbon dioxide. Major components of the pilot plant include a pressure pump, a booster pump, and an inline heater to bring liquid carbon dioxide into its supercritical state. The test results show that the pilot plant readily achieves the injection pressure and temperature, showing satisfactory control performance. The overall power consumption is 2,000 ~ 2,500 W, more than 75% of which consumed by the pressure pump. This study will facilitate varied research on greenhouse gas reduction as the only domestically developed system for geological injection.

  • PDF

An Integrated Management System of the Educational Equipments and Contents of Secondary School (중등학교의 교육 기자재 및 콘텐츠 통합 관리 시스템)

  • Park, Sun Hwa;Park, Jae Heung;Seo, Yeong Geon
    • Journal of Digital Contents Society
    • /
    • v.16 no.2
    • /
    • pp.197-205
    • /
    • 2015
  • These days due to the introduction of the subject classroom system, the classrooms for the subject are arranged and various advanced educational equipment is provided in the classroom such as the actual object image processor, electronic blackboard, and educational photographer which are helpful to the class. With the increase of these equipments, the number of remote controller of individual educational equipment also increases, therefore it is complicate to manage the remote controllers and teachers need to learn the usage of them. So the system supports a remote control for managing the educational equipment by the one remote controller and the instructional supplement. The system consists of the hardware which is similar to popular remote controller and the software which is installed on the teacher's PC and supports controlling the educational equipments, recording the instruction, writing on the blackboard, and automatic power off of the equipment. By introducing the system the teacher could reduce the time consumed by the equipment's control and useless electric waste.