• 제목/요약/키워드: Construction noise and vibration

검색결과 582건 처리시간 0.026초

건설공사장 가설방음벽의 음향 특성 (Acoustic Properties of Temporary Noise Barriers on Construction Site)

  • 정진연;임정빈;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 2010
  • The noise by the construction activities is one of the main issues in Korea. To prevent the noise from construction site, construction company installs temporary noise barriers along the construction site boundary. Normally sound insulation performance ($R_w$) of the temporary noise barriers made by metal or plastic is between 18 and 31 dB and metallic noise barriers are around 5 dB higher than plastic noise barriers. Sound absorption performance (NRC) of the temporary noise barriers are between 0.20 and 0.59 so it's difficult to characterize their acoustic performance. In this study, it has founded that sound insulation performance of the temporary noise barrier has been improved about 3dB by stick the high density acoustic sheet and insertion loss of noise barrier is getting increased as the source and receiver approached the temporary noise barriers.

공사장 방음시설 설치기준 개선방안에 관한 연구 (A study on the improvement for installation guide of soundproofing facilities in construction site)

  • 박영민;김경민
    • 환경영향평가
    • /
    • 제22권4호
    • /
    • pp.361-367
    • /
    • 2013
  • Noise and vibration occurs during construction intermittently, but with the most arise complaints. There is a need to efficiently manage the construction noise and vibration problems because in case a residential facility that requires calmness around the construction site adversely affects the living conditions of nearby residents. The ministry of environment has mandating the installation of soundproofing facilities for the management of construction noise. In order to enforce a particular construction, the mandatory install with soundproofing facilities before the start of construction, and after construction. However, Installation guide of soundproofing facilities for construction sites were not considered affected areas by noise and there is no provision of performance evaluation for soundproofing facilities. In this study, investigated the status and problems of the installation guide for soundproofing facilities in construction sites, we propose an efficient installation guide of soundproofing facilities for the reduction construction noise.

건설소음 예방을 위한 현장용 간이 합성소음 예측프로그램 개발 (Development of the Simple Prediction Program to Prevent Construction Noise in Site)

  • 방종대;송희수;경태욱;임병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.59-65
    • /
    • 2005
  • The research is an objective which prevents a construction noise by developing prediction program on utility, helps comprehension of construction noise by case study. The program developed with Visual Basic of the Excel Logic. The standard noise is a data with report of the construction machine (National Institute of Environmental Research), construction noise of sound pressure level applied the distance decrease of the point source. The decrease effect of the barrier noise wall used the data of 5, 10, 15, 20dB where the diffraction is reflected. used a program, case study is suggested Prevention method to prevent noise of construction site.

  • PDF

건설 공사장 간이 소음 예측 프로그램 개발 (Development of Noise Prediction Program in Construction Sites)

  • 김하근;주시웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1157-1161
    • /
    • 2007
  • A construction noise is the main reason for people's petition among the pollution. The purpose of this study is to develop the noise prediction program to see the level of the noise on the construction site more accurately. For this purpose, the database of the power level on the various equipments was made. The noise reduction by distance and the noise reduction by diffraction of barrier were mainly considered and calculated. The simple noise prediction program will provide the information about proper height and length of the potable barrier which satisfies noise criteria of the construction sites from a construction planning stage. To investigate the reliability of this program, the predicted data was compared with the measured data. An average of difference between measured data and predicted data is 1.3 dB(A) and a coefficient of correlation is about 0.95.

  • PDF

건설기계 소음표시의무제도 연구 (A Study on Noise Marking Obligation System for Construction Equipments)

  • 이성호;박인선;장서일;오진우;권태우;박상규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.554-558
    • /
    • 2004
  • With the improvement of living quality, people's desire for quiet living environment keeps increasing. In particular, complaints about the noise emission by constrcution equipments around residential areas take most part of the noise related complaints. In this study, noise marking obligation system for the high noise construction equipment have been proposed to reduce the noise level and protect the well-being of citizens. For this purpose, construction equipment used in the country were surveyed and compared with that of the European Directive/2000/14/EC. As results, 20 kinds of construction equipment were proposed for the obligated noise marking, while 13 kinds of construction equipment were proposed for the equipment subject to permissible noise level, thus the obligated noise marking and certification.

  • PDF

건설현장에서 발생하는 유압식 항타진동의 특성에 관한 연구 (A Study on the Characteristics of Piling Vibration by Oil Pressure Method in Construction Field)

  • 박재영;곽광수;윤해동;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.921-926
    • /
    • 2000
  • Recently, in construction field, large construction equipment are used to reduce the construction schedule and labor cost. Therefore, construction vibration has caused much annoyance and that induced from operating of large construction equipment, has become a major problem for a number of dwellers in nearby construction field and it has become a very serious issue in our living environment. In this point, this study attempts to survey on the characteristics of piling vibration by oil pressure method in construction field. And this study intends to get the basic data to establish a standard about construction vibration.

  • PDF

흥인지문 인접 CIP공사시 진동 전달 특성 분석 및 평가 사례 연구 (A Case Study of Analysis and Evaluation of Vibration by Construction of Cast in Place Concrete Pile in the Neighboring Areas of Heunginjimun)

  • 최재성;민경원
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.870-878
    • /
    • 2012
  • This paper analysed the effect on Heunginjimun of ground vibrations due to C.I.P. works during Heunginjimun restoration period. Vibration criteria and laws for historic structures was investigated. The vibration was measured under test construction in the field, analysed and evaluated. Because the ground vibration exceeded the vibration criteria, the restoration construction could not be go along. But as vibration was transferred to the upper structures, it was confirmed that vibration levels declined, because of differences between natural and forced frequencies. If the natural frequencies database of historic structures are established, it will help with management and preservation of cultural properties by an environmental vibration effects evaluation.

울산시 소음예측지도 작성에 관한 연구 (A Study on the Construction of 3D Noise Map for Ulsan-City)

  • 이장명;송창섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.144-145
    • /
    • 2010
  • 3-D noise map of Mugue Dong of the Ulsan City has been constructed. Comparing with the measured noise level, the predicted noise level has been confirmed for its accuracy. Correction factors for better prediction result using the constructed noise map have been investigated proving that its method is useful. The procedure of noise map construction method has also been introduced using RLS-90, Cadna A.

  • PDF

생활소음종합대책:추진방향과 기본목표 (Community Noise: New Guidelines and Policy)

  • 김정태;박영민;전종철;박종석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.86-88
    • /
    • 2006
  • Community noise has been serious social issues in Korea. The community noise concerns on traffic, construction, factory, and apartment complex noise. In traffic noise, road, railway, airport sectors are included. This paper summerizes the final report prepared for MOE in 2005 by authors. The new policy will be enforced beginning in 2006 with 5 year schedule. Details on the policy will be demonstrated at the presentation.

  • PDF

사업장소음분야 : 현황과 문제점 및 실천계획 (Industrial noise : current problems and practical plan)

  • 장서일;오유순;전형준;고준희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.102-106
    • /
    • 2006
  • Community noise has been serious social issues in Korea. The community noise concerns on traffic, industrial and apartment complex noise. In industrial noise, construction, factory sectors are included. This paper summerizes the final report prepared for MOE in 2005 by authors. The new policy will be enforced beginning in 2006 with 5 year schedule. Details on the policy will be demonstrated at the presentation.

  • PDF