• 제목/요약/키워드: Construction Insulation Materials

검색결과 160건 처리시간 0.031초

The Design Criteria for the Model Development of the New-hanok Type Public buildings - Focused on Expert Opinion Surveys -

  • Park, Joon-Young;Bae, Kang-Won;Kim, So Young;Jung, Kyung-Yoon
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: According to the characteristic of hanok public building, Planning criterion of structure, technology, efficiency, design is needed which can includes various type of new-hanok type public buildings. In this paper, we collect expert opinions to be used as a basis for developing models of New-hanok type Public Buildings. Method: This study was conducted in Research Study and expert surveys. The Part of reviewing Study looked at conception of new-hanok type public buildings model development and overview planning criterion set briefly. Expert surveys were targeted to professors and architects who are related in new-hanok type public buildings model development research. Result: In this study, we suggest improvement direction about planning criterion of new-hanok type public buildings model development based on opinions collected by expert surveys. In conclusion, first, In concept and legal status, it is necessary to adjust clearly than the term and legal status of new-hanok type. Second, various applicability is needed by using new materials and new construction method at the part of planning elements. Third, 'composed structure-convergence type' and 'composed structure-juxtaposed type' should be clearly classified or combined at the part of Setting of type. Forth, improvement on heat insulation, soundproof, waterproof efficiency is demanded to roof, wall, window systems. Fifth, arranging revitalization plan is important.

초미세입자 제거를 위한 나노세라믹 필터의 성능 평가 (Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

신도시 친환경 주거단지조성을 위한 소음저감 대책방안 (Noise Reduction Method for Environment Friendly Housing Estate)

  • 김흥식;주문기;주시웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.535-541
    • /
    • 2004
  • For housing estate of a new administrative capital city, Noise reduction method is a important design factor. As measuring a noise level of traffic noise according to separation from road, it can be created a quite housing estate. Analyzing of merits and demerits in sound barrier walls and tunnels can be proposed environment friendly soundproofing facilities. Number of measurement was performed to know what kind of layout of housing estate is good for noise reduction. Through this measurement, ㄷ shaped layout or parallel layout has the advantage of sound insulation rather than right angled layout. In this case (ㄷ shaped layout or parallel layout) buildings neighboring to the road should be designed to insulate sound. Evergreen trees should be planted between housing estate and road more than 30m (at least 7~8m) in order to reduce noise and have masking effects. If broad-leaved trees are planted more than 30m, approximately 10dB noise is reduced and 2~4dB if 7~8m. Roads in the estate should be designed considering pedestrians first, and special roads for moving and ambulance should be designed as skew road, if possible. The result shows that 15$^{\circ}$-sloped‘S’road reduces 1~2dB noise and 30$^{\circ}$-sloped road reduces 4~7dB. If noise barrier is inevitably installed, it should be designed to go well wit neighboring environment so as to install Environment Friendly Noise Barrier using materials and trees including wood and soil. Through this study the results are used to guideline for construction of environment friendly housing estate

  • PDF

Structural glass panels: An integrated system

  • Bidini, G.;Barelli, L.;Buratti, C.;Castori, G.;Belloni, E.;Merli, F.;Speranzini, E.
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.327-332
    • /
    • 2022
  • In building envelope, transparent components play an important role. The structural glazing systems are the weak element of the casing in terms of mechanical resistance, thermal and acoustic insulation. In the present work, new structural glass panels with granular aerogel in interspace were investigated from different points of view. In particular, the mechanical characterization was carried out in order to assess the resistance to bending of the single glazing pane. To this end, a special instrument system was built to define an alternative configuration of the coaxial double ring test, able to predict the fracture strength of glass large samples (400 × 400 mm) without overpressure. The thermal and lighting performance of an innovative double-glazing façade with granular aerogel was evaluated. An experimental campaign at pilot scale was developed: it is composed of two boxes of about 1.60 × 2 m2 and 2 m high together with an external weather station. The rooms, identical in terms of size, construction materials, and orientation, are equipped with a two-wing window in the south wall surface: the first one has a standard glazing solution (double glazing with air in interspace), the second room is equipped with the innovative double-glazing system with aerogel. The indoor mean air temperature and the surface temperature of the glass panes were monitored together with the illuminance data for the lighting characterization. Finally, a brief energy characterization of the performance of the material was carried out by means of dynamic simulation models when the proposed solution is applied to real case studies.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.

배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성 (Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used)

  • 이승한;정용욱;장석수;여인동;최종오
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4602-4609
    • /
    • 2013
  • 온도차가 극심한 하절기와 동절기 콘크리트 타설의 경우 각종 균열의 발생, 콘크리트 품질불량, 내구성 및 강도저하 등 다양한 문제를 야기 시키고 있다. 특히 원전콘크리트의 경우 대량의 타설로 인한 4계절 연속시공이 이루어져 서중환경에서 콘크리트 품질관리에 많은 문제점이 발생되고 있는 실정이다. 이에 본 연구에서는 서중환경에서 많이 사용되어지는 프리쿨링 공법 중 배합수 냉각방법과 지연제 사용이 원전콘크리트의 특성에 미치는 영향을 검토하였다. 배합수 냉각방법은 냉수 $5^{\circ}C$와 Ice Flake 50% 치환사용 하였으며, 지연제 사용에 따른 원전콘크리트의 굳지 않은 콘크리트 및 경화 후 콘크리트의 특성을 검토하였다. 굳지 않은 콘크리트 특성으로는 슬럼프, 공기량, 응결시간 및 경화 후 압축강도를 측정하였으며, 단열거푸집을 제작하여 손실되는 열을 최소화시켜 각 온도조건하에서 수화열을 측정하였다. 실험결과, 슬럼프 및 공기량 경시변화 종료시간은 $20^{\circ}C$에서 120분, $40^{\circ}C$에서 40분으로 나타났으며, 관입 저항에 의한 응결시간은 배합수 냉각방법 및 지연제 사용 모두 초결과 종결을 지연시키는 것으로 나타났으나, 외기온도가 상승할수록 지연폭은 감소하는 것으로 나타났다. 수화열은 배합수 냉각방법 모두 최고온도의 저감과 도달시간을 지연시키는 것으로 나타났으나, 지연제 사용의 경우 최고온도 저감효과는 없는 것으로 나타났다. 또한 재령별 압축강도의 경우 3일, 7일의 초기재령에서 Plain과 비교하여 낮은 강도 값을 나타내었으나, 재령 28일에서는 설계기준강도를 모두 만족시키는 것으로 나타났다.

압축과 비틂을 동시에 받는 복합스터드의 구조적 성능에 관한 연구 (A Study on the Structural Performance of Hybrid Studs Subjected to Compression and Torsion)

  • 정윤진;권영봉;곽명근;배규웅
    • 한국강구조학회 논문집
    • /
    • 제18권5호
    • /
    • pp.543-551
    • /
    • 2006
  • 최근까지 벽식 스틸하우스에 구조재로 주로 적용되어오고 있는 박판냉간성형형강 스터드의 경우 열교현상에 의한 단열상의 문제를가지고 있기 때문에 추가적인 단열재를 사용하여야 한다. 이러한 문제를 해결하기 위한 새로운 개념의 아연도금강판(t =1.0mm-1.2mm)과 난연 강화플라스틱(GFRP) 패널 (t=4.0mm-6.0mm)로 구성된 복합스터드가 개발되었다. 복합스터드 패널을 주택 에 적용하기 위하여, 복합스터드의 구조적인 거동 및 내하력 평가를 수행하였다. 본 논문에서는 ATTM(Axial/Torsional Test machine)을 이용하여 수행된 압축력과 비틂을 동시에 받는 복합스터드의 실험적인 연구결과를 기술하였다. 압축-비틂 실험의 주요 변수는 복합스터드의 길이, 초기 압축력, 가력방법 등이며, 초기 압축력을 일정하게 유지한 상태에서 스터드 시험체가 종국적인 파괴에 이르도록 비틂 하중을 점차 증가시키는 방법으로 실험을 수행하였다. 또한 고강도 아연도금강판과 GFRP의 기계적인 특성을 고려한 비선형 유한요소해석을 수행하여 실험결과와 비교, 검증하였다.

경량기포 콘크리트용 개량분체의 Mock-up 실험평가 (Mock-up Test of Improved Concrete Binders for Lightweight Foamed concrete)

  • 최성용;정광복;김기철;김성수;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.853-856
    • /
    • 2008
  • 경량기포 콘크리트는 건축물 방바닥의 단열, 차음 및 높이차 조정 등의 목적으로 아파트 건설공사 등에 주로 이용되고 있다. 그러나 기존의 경량기포 콘크리트는 소포에 의한 체적감소, 과다한 균열 발생등의 문제점을 가지고 있는데 이를 보완하기 위해 콘크리트 제조에 사용되는 혼화재들을 첨가하여 특수한 특성을 가지는 경량기포 콘크리트용 개량분체가 개발되었다. 그러나 아직도 기포율 저감 및 균열방생등과 같은 문제점이 제기되고 있어 이를 보완하기 위한 연구가 필요한 실정이다. 따라서, 본 연구에서는 선행연구를 통한 개발된 경량기포 콘크리트의 실무적용 가능성에 대하여 분석하고자 실구체로 상정한 모의부재를 제작 후 경량기포 콘크리트를 타설하여 이들의 제반 공학적 특성을 분석함으로써 실용화 가능성을 검토하였는데, 그결과는 다음과 같다. 각종 재료가 혼입된 개량분체인 플레인은 약 230mm의 플로우치를 보여 목표 플로우치를 만족하였고, 100mm부재에서 약 4mm의 침하가 일어나 OPC에 비하여 약 2배의 침하깊이 감소효과를 나타냈다. 강도면에서는 OPC가 가장 높은 강도로 나타났으나, 세 수준 모두 KS기준 0.5품의 규정치를 상회하는 강도이었다. 건조수축 균열에 대한 부재균열 분석으로써 플레인은 약 0.1mm정도로 건조수축 균열에 매우 우수한 것으로 나타났다.

  • PDF

국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사 (Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea)

  • 정종원;유용희;송준익;김태일;전병수;양창범
    • 한국축산시설환경학회지
    • /
    • 제11권3로
    • /
    • pp.169-176
    • /
    • 2005
  • 본 연구에서는 국내 2층 돈사 및 톱밥돈사를 조사하였으며 현재 양돈에 적용되고 있는 분뇨처리 형태, 사육형태, 환기방식 및 돈사건축비의 실태를 현장조사를 통하여 분석, 평가함으로써 이를 바탕으로 우리나라 기후와 조건에 적합한 분뇨처리와 돼지사육이 가능한 고상식 돈사의 건축모델에 적용 가능성을 고려할 목적으로 무창 2층 돈사와 개방식 톱밥돈사 농장을 방문 조사한 결과를 요약하면 다음과 같다. 1. 2층 돈사의 분뇨에 수분조절재로 톱밥, 수피, 왕겨를 사용하였다. 톱밥돈사는 톱밥만을 사용하였으며, 수분조절재의 사용깊이는 대체로 $30\~60cm$로, 이용기간은 평균 $3\~6$개월 정도 이용하였다. 2. 2층 돈사에서 돼지의 사육형태는 1층에서는 주로 임신돈 및 분만돈을 사육하였고 2층은 자돈과 육성돈을 사육하고 있었다. 3. 환기시스템은 기본적으로 2층 무창돈사는 기계적 환기(mechanical ventilation)시스템을 설치하였고 톱밥돈사는 자연환기(natural ventilation)시스템으로 조합되어 있었다. 4. 2층 돈사의 단열재는 블록, 칼라강판 및 샌드위치 판넬 등을 사용하였고 단열재두께는 지붕 $75\~100mm$, 벽이 $50\~75mm$였으며 천장높이는 최소 2.0, 최대 3.0m로 조사되었다. 5. 평당 건축비는 무창 이층돈사는$70\~1,400$천원 이내였으며, 개방식 톱밥돈사는 자체 건축한 곳을 제외하고는 $300\~400$천원 내외로 건축비가 소요되었다

  • PDF

조경용 식생매트의 열전도율 측정에 관한 연구 (A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping)

  • 차욱진;양건석
    • 한국조경학회지
    • /
    • 제46권6호
    • /
    • pp.85-96
    • /
    • 2018
  • 선진국들은 지구온난화의 영향을 최소화하기 위해 1997년 '교토의정서' 채택이후 온실가스를 줄이기 위한 다양한 정책을 시행하고 있다. 우리나라 역시 2030년 온실가스 감축 목표를 배출전망치(BAU: Business As Usual) 대비 37% 줄이기 위해 산업부문, 수송부문, 건물부문의 에너지 소비량을 감축하여야 한다. 정부에서는 에너지 소비량 감축을 위한 각종 법령 및 행정규칙을 제정하여 시행하고 있으며, 특히 건물부문의 에너지 소비량을 감축하기 위하여 녹색건축물 조성지원법에 따른 '건축물의 에너지절약설계기준'을 시행하고 있다. 실내온도를 $28^{\circ}C$로 유지하기 위해 사용되는 전력량은 벽면녹화 및 옥상녹화 등으로 녹화된 건물이 녹화되어지지 않은 건축물에 비해 평균 30%의 전력사용량의 감소효과가 있다. 이렇듯 조경녹화에 대한 에너지 절감의 효과는 입증되고 있으나, 이러한 입증은 '건축물의 에너지절약설계기준'에 적합한 방법이 아니기에 에너지 절감의 실효성을 가지고 있지 못한다. 조경용 녹화가 에너지 절감에 따른 실효성을 가지려면 '녹색건축물 조성 지원법 제14조'의 '건축물의 에너지절약 설계기준'의 단열재료에 대하여 구성재료의 열전도율로 열관류율을 계산하여 '별표 1'의 기준에 적합하여야 한다. 본 연구에서는 3종류의 벽면녹화용 식생매트와 1종류의 복합매트(내부단열재+식생매트)를 제작하여 다양한 열전도율 측정 실험을 수행하고, 에너지 보존식을 이용하여 내부단열재 두께 등에 대하여 이론적인 계산을 하였다. 3종류의 식생매트의 열전도율은 0.130~0.157W/mk 정도로서 목재의 열전도율(0.170w/mk)보다 낮아 단열의 기능을 가지는 매트로써 역할을 할 수 있음을 알 수 있었다. 특히, 복합매트는 내부단열재(그라스포, 폴리우레탄 등)의 두께를 조절하면 '건축물의 에너지절약설계기준의' 단열기준 0.051W/mk에 적합한 식생매트가 될 수 있을 것으로 판단된다.