• Title/Summary/Keyword: Construction Behavior

Search Result 3,620, Processing Time 0.031 seconds

Tensile Behavior of Concrete-Filled Column Connections Using Re-bars (철근을 이용한 충전 강관기둥 접합부의 인장거동)

  • LEE, Young Ryule;YOO, Yeong Chan;SHIN, Kyung Jae;OH, Young Suk;LEE, Seung Joon;MOON, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.89-96
    • /
    • 1996
  • The objective of this study is to investigate the structural behavior of Concrete-Filled Steel Tubular Column connections using reinforced bar. The parameter of specimens is the area of each reinforced bar (SD40 : D13, D16, D19, D22, D25). The simple tensile experiment is conducted to 5 kinds of specimens. Estimating the load, displacement, and strain from each kind, we compared them to basic elementary type (Flange Type, Basic Type, DPA Type, DPB Type). In each specimen, We can get the yielding load obtained by the theoretical three failure modes which make it possible to predict the experimental results. Actually, through the comparison and analysis, we come to know that the experimental results and theoretical results are nealy the same. Further, we will exert to apply the connections using reinforced bar to construction of high-rise building.

  • PDF

A Study on the Structural Behavior of the Composite Slabs using the Metal Form Deck Plate (일반거푸집용 데크플레이트를 이용한 합성슬래브의 구조적 거동에 관한 연구)

  • KWON, Yong Keun;KANG, Do An;CHOI, Sung Mo;EOM, Chul Hwan;CHOI, Oan Chul;MOON, Tae Sup;KIM, Kyu Suk;KIM, Duck Jae;KIM, Dong Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.67-78
    • /
    • 1996
  • This paper provides the results of a study on the structural behavior of the composite slabs using the metal form deck plate. Cold-formed steel deck sections are used in many composite floor slab applications wherein the steel deck serves not only as the form for the concrete during construction but also as the principal tensile reinforcement for the bottom fiber of the composite slab. A total of 16 specimens are tested to clarify the composite action between the concrete and metal deck plate and to find the method to increase the composite effect, whether or not non-slip bars are used. The test results are summarized for the shear-bond capacities, deformation capacities, and failure modes for the specimens.

  • PDF

Introduction of PCC Pavement Sections and Associated Research in KHC Test Road

  • Kim, Ji-Won;Kwon, Soon-Min;Lee, Jae-Hoon;Kim, Do-Wan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.197-203
    • /
    • 2003
  • Korea Highway Corporation(KHC) began the ambitious KHC Test Road construction project from 1997. It is 7.7km long two-lane highway next to the mainline of Jungbu Inland Expressway. The KHC Test Road construction was completed at the December 2002. It is composed of twenty-five PCC test pavement sections. Section design parameters are (1) concrete slab thickness, (2) base type, (3) base thickness (12, 15, and 18cm), and (4) pavement type. Twenty-five PCC test pavement sections contain 1241 sensors to evaluate the behavior of pavement system under traffic load and environmental change. The behavior of pavement systems will be identified by the observation of sensor measurement and pavement distress survey from test pavement sections. The Test Road research outcome will validate the Korean Pavement Design Guide which is develop by on-going funded research from the Ministry of Construction and Transportation.

  • PDF

Prediction of Drying Shrinkage Behavior of Half PC Slab (Half PC slab의 건조수축 거동 예측)

  • Seo, Tae-Seok;Choi, Hoon-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.7-8
    • /
    • 2016
  • The use of half PC slab is increasing to shorten construction period. Because the drying shrinkage of topping concrete is restrained by PC slab, the tensile stress is generated at the topping concrete and the cracks can be occurred at the topping concrete due to drying shrinkage. Therefore, it is important to predict the tensile strain of half PC slab due to drying shrinkage to improve the quality of half PC slab. However, there is no studies on prediction of shrinkage behavior of half PC slab yet. Therefore, in this study, half PC slab was made, and the predictability of tensile strain generated at half PC slab due to drying shrinkage was investigated. The step by step method considering creep was used to estimate the tensile strain of half PC slab. In result, good agreement was obtained between the analytical and experimental values.

  • PDF

Repaired concrete columns with fiber reinforced thixotropic mortar: experimental & FEA approach

  • Achillopoulou, Dimitra V.;Arvanitidou, Konstantinia C.;Karabinis, Athanasios I.
    • Computers and Concrete
    • /
    • v.15 no.1
    • /
    • pp.73-88
    • /
    • 2015
  • Following previous studies, the current paper describes the results of an experimental program concerning the repair of reinforced concrete columns by thixotropic pseudo plastic mortar, preformed to analyze and quantify the influence of initial construction damage to the behavior of the repaired element. Five columns (section scale 1:2) were designed according to the minimum requirements of reinforcement of ductility orientated codes' design with variables the percentages of initial construction damages. All were tested in axial compression with repeated cycles up to failure. For comparison reasons, another one of the same characteristics, yet healthy, was constructed and tested as a reference specimen. A numerical study (Finite Element Analysis) was conducted for further investigation of the behavior of the thixotropic mortar as repair material. The results indicate that: a) surpassing a specific amount of damage, columns even suitably repaired present lower strain capacity, b) finite element analysis present the same way of deboning of the repaired material taking into consideration the buckling of the reinforcement bars.

Repair and Reinforcement Design of Olympic Fencing Arena (올림픽 제2체육관(펜싱경기장)의 보수.보강설계)

  • HwangBo, Seok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.4 s.14
    • /
    • pp.7-14
    • /
    • 2004
  • The analysis method of stabilizing process and its program regarding large spatial structural systems are described in this paper. In this paper, the analysis of stabilizing process of the example structures, namely Olympic Fencing Arena, is performed and the jacking force of stabilizing process is proposed, and the characteristics of structural behavior is investigated. This result of research is applied to the design and construction of the actual structures and the reliability of the analysis is verified through comparison of the analysis results and the measured results in the field. When the analytical results is compared with the actual structural behavior, there is a little difference, but it is thought that the analysis results are quite reliable because it is very similar to the measured values in spite of construction and measurement errors.

  • PDF

An Experimental Study on the Behavior of Full Scaled System Columns Reinforced with Steel Sheet Forms and Angles (강재 영구거푸집을 사용한 실대 크기의 시스템 기둥에 관한 실험적 연구)

  • Kang, Ji-Yeon;Lee, Su-Jin;Yoon, Yeong-Ho;Kim, Hyunh-Geun;Lee, Chang-Nam;Kim, Sang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.21-24
    • /
    • 2006
  • In recent, there are a lot of problems such as shortage of construction workers, complicate progress of work and so on under RC construction. To solve these problems, the construction methods without form-work are used in the main structural members - beam, slab and stairs. However, there isn't yet form-workless system for columns. The purpose of this study was to experimentally evaluate the structural behavior of full scaled no-form system columns reinforced with steel sheet forms and angles. The main variables are 1) comparison of concrete member strength with and without reinforcement, 2) effect of L-angle.

  • PDF

Development of a Separable Glued-Laminated Timber (GLT)-Steel Beam for Eco-Friendly Construction and Dismantling of Buildings (건축물의 친환경 시공·해체를 위한 재료 분리형 GLT-Steel 보 개발)

  • Pang, Sung-Jun;Oh, Jung-Kwon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.23-24
    • /
    • 2023
  • In this study, an easily recyclable separable glued-laminated timber (GLT)-steel beam was developed, and a structural design method was presented. The GLT and steel were mechanically composited using self-tapping screws. The GLT-steel beam was designed to fail in the compression of GLT. The bending moment and load-carrying capacity of the GLT-steel beam were predicted based on composite beam theory and compared with experimental test data. As a result, the GLT-steel beam exhibited ductile behavior, and compression failure of GLT was observed. The screw connection showed no damage while the steel plate was extended. The load-carrying capacity of GLT after failure was similar to the load resistance predicted by the compressive strength of GLT and the tensile strength of steel. This indicates that the ductile behavior of the GLT-steel beam can be safely designed by the tensile strength (yield) of steel.

  • PDF

An example of repair works and leakage analysis for school facility (학교건축물의 누수진단 및 보수방안에 관한 사례 연구)

  • 이재범;권시원;곽규성;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.105-108
    • /
    • 2004
  • The most of former schools facility have been planed and constructed with cement liquid waterproofing which is moth to be desired fir behavior of structure. However. It cause to decline safety for structure and also increase repairing cost that by leakage to behavior for thermal effects, Moreover, It is necessary for establishment fundamental counterplan of maintenance for schools facility to improve educational environment in budget support and proper diagnostic tech. and evaluation, repair reinforcement. In present paper, Firstly, we analyze out leakage and defect of schools facility of ㅇㅇ district office of education. Secondly, suggest the proper diagnostic tech. as leakage factor to develope efficiency of using space for durability and safety from leakage with suggestion the proper diagnostic.

  • PDF

Behavior Analysis from the Site Monitoring Results of Geotextile Reinforced Wall (지오텍스타일 보강토벽의 계측결과에 의한 거동분석)

  • 원명수;이재열;김유성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.145-152
    • /
    • 1999
  • In the applying of the reinforced soil method, it would be possible to obtain reinforcement effect more than before in terms of economic if high water content clayey soils could be used as embanking material. Futhermore it would be possible to expect the expansion of the applying field of reinforced soil method too. In this study, the authors describe the analysis results on the behavior of 5 meter high walls reinforced with nonwoven geotextile having the permeability and woven geotextile or geogrid having large tensile strength on the soil ground. The behavior of the walls were investigated for about 100 days after construction and the deformations of reinforcements, lateral soil pressures, vertical and horizontal displacements of the walls were examined by automatical measuring system. It was found that this kinds of reinforcing system might effectively improve the performance of the steep walls by virtue of the reciprocal action between soil and reinforcements, and it might be concluded that construction of the clayey reinforced soil walls with three kinds of geotextiles could be done successfully even on the comparative weak ground.

  • PDF