정유량 밸브의 카트리지의 오리피스 구멍의 유출계수 (Discharge Coefficients of Orifice Hole in the Cartridge of Constant Flow Control Valve)

  • 유선학;강승덕;양의석;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.305-308
    • /
    • 2004
  • The constant flow control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have similar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the constant flow control valve was developed. The performance of this control valve is effected by hole area and discharge coefficients of the cartridge holes. The discharge coefficients of orifice hole in the cartridge were testes with various sizes of holes and various flow direction in the holes. The discharge coefficients decreased as the hole size increased due to the collision at the cartridge wall of water jet. The effects of the flow direction at the hole were not significant on the discharge coefficients.

  • PDF

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

Y형 세대별 정유량 밸브 개발에서의 CFD의 활용 (CFD for Y-type Constant Flowrate Valve Design)

  • 권우철;이병휘
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.488-491
    • /
    • 2004
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve shape is carried out to confirm the flow field whether the designed valve shape is good or not. The simulation of the incompressible flow in a constant flowrate control valve is performed by using the commercial code, FLUENT/UNS 6.0. The results of flow field show the designed valve has some problems, therefore these will be good data for new valve design.

  • PDF

바닥복사냉방의 결로방지를 위한 제습제어에 관한 연구 (A Study on the Dehumidification Control to Prevent Condensation for Radiant Floor Cooling)

  • 김용이;김광우
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.137-143
    • /
    • 2003
  • In the forming of an integrated system of radiant floor cooling and dehumidifying, chilled coil can be used for cooling and dehumidification. Therefore, it is necessary to find the efficient control method which can eliminates latent load efficiently. This study has been conducted to find this method by dividing the dehumidification system into 3 types according to the control variables and analyzing characteristics of each system. To prevent the floor surface condensation, the amount of condensation can be manipulated by water temperatures, water flow rates in chilled coil, and air flow rates passing by it. So dehumidification system control can be divided into constant air flow control and variable air flow control. Regarding dehumidification control, variable air flow control, which eliminates latent load rather than sensible load, is preferable to constant flow control.

Simulation on Hydraulic Control Characteristics of Regulator System in Bent-Axis Type Piston Pump

  • Kim, Jong Ki;Oh, Seok Hyung;Jung, Jae Youn
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.101-106
    • /
    • 2000
  • Variable displacement axial piston pumps are widely used for raising the energy level of the fluid in hydraulic systems. And the regulator is the device which regulates the discharge flow of the piston pump by controlling the swivel angle. The regulator receives the hydraulic pilot pressure and controls the pump output flow depending on the machine load and engine speed. This work deals with constant power control (horsepower control) in the design of a regulator by using a bent-axis type piston pump. In order to effectively use engine power, we must keep the horsepower from the engine to the pump constant. Therefore the regulator operates the constant power control. As a result, optimum power usage is obtained by accurately following the power hyperbola. This study focused on developing a simulation model of a regulator. First, the governing equations of the regulator are derived, and analysis is performed by computer simulation, which can identify significant parameters of regulator. As a result, the variation of the swivel angle, flow rate, hyperbolic curve, inner leakage and responsibility are simulated, and significant parameters of a regulator are identified.

  • PDF

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

대형 팬의 효율적 유량 조절을 위한 루버 개폐각 상관관계 (CORRELATION BETWEEN THE OPENING ANGLE OF A LOUVER AND FLOW RATE FOR THE EFFICIENT CONTROL OF A LARGE FAN)

  • 노태현;이상진;장세명
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.272-276
    • /
    • 2007
  • In this paper, we researched a parametric study in flow control system using louver with numerical method. Generally, for the large fans with constant rotational speed, the louver can be used to control the flow rate. The opening and closing of louver can make a some change of flow properties generated by a large fan. To develope the relation between the opening angle of louver and flow rate(or pressure difference), we simulated the flow past the modelled louver installed in a virtual wind tunnel. For the various angles, the mean flow properties are investigated and parameterized with a given boundary condition. The research result can be used directly to design the flow control system of large constant-speed fans, which are often applied to petrolic refinery system.

  • PDF

열전대 센서와 압전체 구동기가 부착된 유량제어기의 DC 이득과 시상수를 이용한 제어에 대한 연구 (A Study for Control using DC Gain and Time Constant of Flow Controller Operated by Piezoelectric Actuator and Thermocouple)

  • 이상경;김영수
    • 한국기계가공학회지
    • /
    • 제3권1호
    • /
    • pp.79-83
    • /
    • 2004
  • This study was how to control the mass flow controller in gas supplying system. The flow controller consists of piezoelectric material and sensor with heating wire. It is difficult to obtain accurate model, because MFC was composed of many parts, and the relationship between input and output of controller is nonlinear. The model for control was obtained by time constant and DC gain Based on this model, PID controller was applied to flow controller using DSP board. Also, the results were compared to controller using system identification.

  • PDF

분산전원의 구성 및 출력 제어 방법에 따른 Droop 계수 설정 방법 (A Method to Determine the Droop Constant of DGs Considering the Configuration and Active Power Control Mode)

  • 안선주;박진우;정일엽;문승일
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1954-1961
    • /
    • 2008
  • Microgrid usually consists of a cluster of distributed generators(DGs), energy storage systems and loads, and can operate in the grid-connected mode and the islanded mode. This paper presents detailed descriptions of two different options for controlling the active power of DGs in the microgrid. One is regulating the power injected by the unit to a desired amount(Unit output power control) and the other is to regulate the flow of active power in the feeder where the unit is installed to a constant(Feeder flow control). Frequency-droop characteristics are used to achieve good active power sharing when the microgrid operates in the islanded mode. The change in the frequency and the active power output of DGs are investigated according to the control mode and the configuration of DGs when the microgrid is disconnected from the main grid. From the analysis, this paper proposes a method to determine the droop constant of DGs operating in the feeder flow control mode. Simulation results using the PSCAD/EMTDC are presented to validate the approach, which shows good performance as opposed to the conventional one.

정압비례제어방식을 적용한 정압급수장치의 개발 (Development of a constant pressure feed system using a constant pressure proportional control mode)

  • 김주명;김광열;이건기
    • 한국정보통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.1026-1031
    • /
    • 2003
  • 자동 급수펌프는 압력스위치에 의해 운전 및 정지를 하게 된다. 따라서 수량 증감에 따른 펌프의 빈번한 운전 및 정지로 인해 지속적인 정격 및 정압 운전이 불가능하다. 또한 빈번한 작동으로 인해 지속적으로 일정한 압력을 얻을 수 없으며, 펌프의 소손과 에너지의 낭비가 심한 단점을 가지고 있다. 본 논문에서는 이러한 단점을 해결하고자 급수밸브, 유량센서, 제어장치로 구성되는 정압 급수장치를 설계 제작하였다. 급수밸브는 유출되는 물의 양과 관계없이 항상 일정한 양의 물을 유입하여 펌프의 부하를 줄이는 역할을 한다. 유량센서는 적외선 다이오드를 사용하여 유출되는 물의 양의 측정하며, 제어장치는 8 비트 마이크로프로세서를 이용하여 설계하였으며, 특별한 제어 알고리듬에 의해 펌프의 운전과 정지를 제어하게 하였다. 본 논문에서 개발한 장치는 토출 압력이 일정하게 유지되고 펌프의 작동 및 정지 동작이 부드럽게 이루어지며, 펌프의 지속적인 정압운전이 가능하므로 기존의 단점을 보완하는 장치로 사료된다.