• Title/Summary/Keyword: Constant-Current Control

Search Result 696, Processing Time 0.022 seconds

Novel Current Compensation Technique for Harmonic Current Elimination (고조파 전류 제거를 위한 새로운 전류 보상 기법)

  • Jeong Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF

Instantaneous Current Control for Parallel Inverter with a Current Share Bus (전류공유버스를 이용한 병렬 인버터 순시 제어기 설계)

  • 이창석;김시경
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Study on Current, Velocity, Position Gain Tuning Technique of Servo Position Controller using Simulation (시뮬레이션을 이용한 서보 위치제어기의 전류, 속도, 위치이득 동조기법에 관한 연구)

  • Park, Ki-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.7
    • /
    • pp.634-640
    • /
    • 2011
  • When a servo position controller of a robot or a driving units is composed of a PID controller, servomechanism which is modelled is composed of current, velocity and position control loops. After this model is simulated, the technique operating gain of each controller is suggested. The model consists of current, velocity and position controllers from the inside to the outside gradually. Also, to combine velocity and position controllers with 2 order system, simulation is performed after current controllers are composed, which are able for current loop to work ideally. If a current controller is treated with constant, it is possible for velocity and position controller to consist of controller into 2 order system. The technique is verified by applying T-company servo motor which is much more applied to current, velocity and position controller robots.

Characteristic comparisons of the constant current LED driver by the ripple of the input voltage (LED 정전류 구동회로의 입력전압 리플 크기에 의한 특성 비교)

  • Park, Chong-Yeun;Jeon, In-Ung;Yoo, Jin-Wan;Choi, Young-Min
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.115-118
    • /
    • 2012
  • Recently, there are a lot of papers in order to replace the electrolytic capacitor into the film capacitor in output of PFC(Power Factor Correction). However, the film capacitor, which has capacitance of low values, causes a large ripple voltage in output of PFC. The LED drivers are connected series in the output of PFC and affected by the magnitude of voltage ripple. In this paper, we have compared the fixed frequency method with the variable frequency for the constant-current control and propose the control method to avoid the sub-harmonic oscillation in the variable input voltage. An 80W PFC, using film capacitors instead of electrolytic capacitors, and LED driver has been built and compared the fixed frequency control method with the variable frequency control method.

  • PDF

Alternating Current (AC) Powered LED Lighting Technology with Constant Brightness (빛의 밝기가 일정한 교류 구동 LED 조명기술)

  • Lee, Dong Won;Ahn, Ho-Myoung;Kim, Byungcheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.466-470
    • /
    • 2022
  • In order to widely disseminate LED lighting, LED lighting technology that directly uses AC commercial power has been recently introduced. AC powered LED lighting technology has a problem in that the light brightness of the LED changes because the voltage applied to the LED and the current flowing through the LED continuously change. In this study, when the LED current is greater than the design current, the current control signal generated by the controller is supplied to the current source to supply only the design current to the LED by increasing the voltage drop at the current source. If it is smaller than the design current, the controller is adjusted so that the current is supplied only to the LED without a voltage drop in the current source. It can be seen that the higher the maximum rectified voltage, the faster the lighting time of the LED light emitting block is, so that the power factor of the LED lighting is improved. The LED lighting technology proposed in this study enables LED lighting with constant light brightness, reduced power consumption, and long lifetime.

Performance Improvement on Cycloconverter-fed Induction Motor Speed Control System (공침법을 이용한 PbTiO3-Polymer O-3 압전 Composites)

  • Cho, Ok-Kyun;Shin, Hwi-Beom;Yuon, Myung-Joong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.352-359
    • /
    • 1987
  • The cycloconverter operating on a circulating current-free mode has many zero crossing points. If an exact zero crossing points are not detected, the three phase-unbalanced currents will flow in a motor. In this paper, the current feedback using a current reference wave is proposed to improve the problems of zero crossing detection, three phase-unbalanced voltages, currents, and torgue ripples. To prevent the saturation of the air gap flux and keep the torque constant, the constant voltage / hertz control with IR compensation is adopted. The PI-controller is designed using the linearized model of the cycloconverterinduction motor system. Alsi, Z-80A single board computer has been used to implement the proposed scheme which results in the performance improvement of cycloconterter-fed induction motor speed control system.

  • PDF

Torque-Fluctuation Reduction Inverter for SRM Driving (SRM구동용 맥동토오크 저감형 인버어터에 관한 연구)

  • 박성준;추영배;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.46-52
    • /
    • 1998
  • This paper describes a current-shaping method for the production of constant torque of SRM under the nonlinear magnetic saturation condition. A current detection technique in the inductance increasing region and an approximation technique for modeling of nonlinear inductance profile are adopted. In the proposed system, a single switching angle control and voltage control is used to shape the current waveform for the generation of flat torque at any given load condition. Finally the validity of the proposed method was verified using a constructed 3HP 6/4 SRM.

Experiment of Single-phase Grid Connected Battery Charger (5kW급 계통연계형 단상 배터리 충전기의 구현 및 실험)

  • An, Hyun-Sung;Lee, Wujong;Mun, Byung-Ho;Park, Il-Kyu;Jung, Seon-Yong;Kim, Youngroc;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.84-90
    • /
    • 2013
  • This paper explains control methods of single-phase grid connected battery charger. Charging mode is control by Constant Current - Constant Voltage method and discharging mode is controlled by active-reactive power control method. Current control method is based on the synchronous reference frame(SRF) PI controller, and the second harmonic of battery current is compensated by an added L-C resonant circuit. Feasibility of the proposed control methods is verified through experiment with a prototype of 5kW single-phase grid connected battery charger.

An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator (3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법)

  • Moon, Hyoung-Soo;Han, Woo-Yong;Lee, Chang-Goo;Sin, Dong-Yong;Kim, Mu-Youn
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF

High Power Density Open-frame Type DC-DC Converter Module with Constant Current Control (정전류 제어 기능이 부가된 고전력밀도의 개방형 DC-DC 컨버터 모듈)

  • Lee Darl-Woo;Ahn Tae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.380-387
    • /
    • 2005
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and single ended rectifier. The converter module is designed with the specifications of an 3.3V output voltage, 30A output current, 100W output power and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction loss at high current level and constant current control using precision PCB resistance is adapted to enhance the over current protection function in the system configuration. A prototype converter module is successfully implemented within 8mm height and quarter brick size (58x37mm) and recorded an $95W/in^3$ power density, 90.6$\%$ efficiency and 0.07$\%$ voltage regulation for the entire Input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.