• 제목/요약/키워드: Constant rate model

검색결과 888건 처리시간 0.024초

Mathematical description of drug distribution in the isolated organ

  • Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • 제3권1호
    • /
    • pp.13-16
    • /
    • 1980
  • The model of an isolated organ system has been constructed to simulated the behavior of drug in the circulatory system of an acting organ or site. The model is developed on the following assumptions : The drug in the microcirculatory system cannot permeate the capilary walls. The capilary bed is modeled as a simple ideal plug flow system with and without radial concentration gradient. The mathematical model is developed from basic considerations of drug distribution with hemodynamical and pharmacokinetical meanings. It is considered that a nonmetabolic drug substance is injected into the arterial inflow site of an isolated organ at a constant rate. The concentration of the drug in the outflow site is mathematically expressed as a function of time.

  • PDF

Kinetic modeling of organic and nitrogen removal from domestic wastewater in a down-flow hanging sponge bioreactor

  • Nga, Dinh Thi;Hiep, Nguyen Trung;Hung, Nguyen Tri Quang
    • Environmental Engineering Research
    • /
    • 제25권2호
    • /
    • pp.243-250
    • /
    • 2020
  • A down-flow hanging sponge (DHS) bioreactor was operated for the treatment of domestic wastewater. The Stover-Kincannon model was applied for kinetic evaluation of the reactor performance during the operational period. As a result, the coefficient of determination (R2) for straight lines of effluent concentration from the experimental data and from the predictive data of BOD5; NH4+-N; and TN were 0.9727; 0.9883; and 0.9934, respectively. The calculation of saturation value constant (Umax - g L-1 d-1) and maximum utilization rate constant (KB - g L-1 d-1) were 56.818 and 75.034 for BOD5; 2.960 and 4.713 for NH4+-N; 2.810 and 8.37 for TN, respectively. The study suggests that Stover-Kincannon model can be used for effective evaluation of kinetic removal of BOD5; NH4+-N; and TN from domestic wastewater treated in a DHS bioreactor.

고무의 힘-변위 관계를 나타내는 모델링에의 볼테라 급수의 응용 (Application of Volterra Series to Modeling an Elastomer Force-Displacement Relation)

  • 성단근
    • 대한전자공학회논문지
    • /
    • 제26권6호
    • /
    • pp.71-78
    • /
    • 1989
  • 비선형 시스템의 입출력 관계는 볼테라 급수로 나타낼 수 있으며 그것은 볼테라 커널에 의해 규명될 수 있다. 본 연구는 소수의 볼테라 급수항을 사용하여 계단 입력에 의한 고무의 힘-변위 관계를 모델링하는데 관한 것이다. 무한의 기울기를 가진 계단 입력을 가하여 얻어진 실험결과에서 일정한 압축시의 계단입력에 대한 결과를 예측한다. 비스코일레스틱 재료를 나타내는 현저한 특징중의 하나인 힘-변위 관계를 모델링하기 위해 2차와 3차 볼테라 급수 모델을 사용한다. 3차 볼테라 급수 모델이 2차 볼테라 급수 모델의 결과에 비해 더 좋은 결과가 얻어지고 있다.

  • PDF

유체 누출에서의 음향방출 신호분석 (Analysis of Acoustic Emission Signals from Fluid Leakage)

  • 김용민;윤용구;김호철
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.413-421
    • /
    • 1990
  • Acoustic emission signals due to leak from circular holes of 0.4, 1, 2 and 4mm diameter and rectangular slits of different geometry having the same cross section as 4mm diameter hole was studied both analytically and experimentally. Acoustic emission signals from a wide-band type transducer were transformed to digital signals through a digital oscilloscope, and $V_{rms}$ and frequency spectrum were obtained by processing digital signals. Relationships between acoustic parameters and fluid mechanical parameters were derived analytically. A quadrapole aerodynamic model was applied in the analysis of leak from the circular holes and $V_{rms}$ was found to be proportional to the root square of leak rate through the circular hole. A modified model based on dipole source mechanism and laminar equivalent diameter was applied in the analysis of leak signals from the rectangular slits. In the case of constant pressure, $V_{rms}$ increased as the laminar equivalent diameter of slit decreased. In the case of constant laminar equivalent diameter, however the result was similar to that for leak from the circular hole. The frequency spectra of leak signals shows the same frequency characteristics irrespective of the pressure difference.rence.

지하수 모델링 기법을 이용한 인공함양정 최적 위치 평가 (Determining Optimal Locations of an Artificial Recharge Well using an Optimization-coupled Groundwater Flow Model)

  • 이현주;구민호;김용철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권3호
    • /
    • pp.66-81
    • /
    • 2014
  • A Fortran program was developed to determine the optimal locations of an artificial recharge well. Three objective functions were considered: (1) maximizing the recovery rates, (2) maximizing the injection rates, and (3) minimizing the coefficient of variation of the increased pumping rates. We also suggested a new aggregate objective function which combined the first and the third objective functions. The model results showed that locating the injection well inside the cluster of pumping wells was desirable if either the recovery or the injection rate was taken into account. However, the injection well located outside the cluster evenly increased the pumping rates in existing pumping wells. Therefore, for clustered pumping wells, installing an injection well at the center or the upstream of the pumping wells seems beneficial. For linear arrangement of pumping wells parallel to the constant head boundary, locating the injection well in the upstream was recommended. On the contrary, in case of the linear arrangement perpendicular to the constant head boundary, the injection well installed on both sides of the central part of the pumping wells was preferable.

Z-map 기반 가공 검증모델을 이용한 칩부하 제어기 (Chip Load Control Using a NC Verification Model Based on Z-Map)

  • 백대균;고태조;박정환;김희술
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.68-75
    • /
    • 2005
  • This paper presents a new method for the optimization of feed rate in sculptured surface machining. A NC verification model based on Z-map was utilized to obtain chip load according to feed per tooth. This optimization method can regenerate a new NC program with respect to the commanded cutting conditions and the NC program that was generated from CAM system. The regenerated NC program has not only the same data of the ex-NC program but also the updated feed rate in every block. The new NC data can reduce the cutting time and produce precision products with almost even chip load to the feed per tooth. This method can also reduce tool chipping and make constant tool wear.

ATM 망에서 MPEG 비디오 서비스를 위한 Traffic 동적 할당에 대한 연구 (A Study on The Traffic Control Using ATM OAM Cell for MPEG Video Service in ATM Networks)

  • 김민호;이병호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.87-90
    • /
    • 1998
  • Many recent studies have been conducted involving the transport of constant and variable bit rate MPEG-2 video in asynchronous transfer mode (ATM) networks. In this study, the traffic control of supporting MPEG-2 video communications in ATM networks under unloaded or loaded network conditions, in which the generated traffic sources are bursty in nature, are considered. We analyse about MPEG-2 traffic and design a model, which makes use of the ATM OAM funcation in order to support the traffic control functions. To implement the model, we propose a scheme, which combines the performance management OAM function and the bandwidth allocation function. Especially, we design this scheme to control the VBR (Variable Bit Rate)MPEG-2 video traffic.

  • PDF

Optimization of a Model for an Inventory with Poisson Restocking - Optimization of an Inventory Model -

  • Lee, Eui-Yong;Han, Sang-Il;Kim, Honggie
    • 품질경영학회지
    • /
    • 제22권1호
    • /
    • pp.214-218
    • /
    • 1994
  • An inventory supplies stock continuously at a constant rate. A deliveryman arrives according to a Poisson process. If the level of the inventory, when he arrives, exceeds a threshold, no action is taken, otherwise a delivery is made by a random amount. Costs are assigned to each visit of the deliveryman, to each delivery, to the inventory being empty and to the stock being kept. It is shown that there exists a unique arrival rate of the deliveryman which minimizes the average cost per unit time over an infinite horizon.

  • PDF

모델에 의한 흡배관내 연료유동의 거동에 관한 실험염구 (An experimental study on the behavior of fuel flow in intake manifold by the model)

  • 박경석
    • 오토저널
    • /
    • 제5권3호
    • /
    • pp.33-44
    • /
    • 1983
  • This paper deals with the experimental study on the behavior of fuel (methanol) in intake manifold by using the basic apparatus which is manufactured the visible straight tube type model. In this study, the new device for liquid film thickness measurement and vaporization rate measurement are introduced to investigate the variation of liquid film thickness along the intake manifold and to observe the effect of vaporization of injected fuel. the results are summarized as follows: 1) The vaporization rate increases in proportion to decreasing of throttle valve angle and growing air fuel ratio. 2) The liquid film thickness along the intake manifold is mostly independent for the throttle valve angle in low air velocity and then affected in high air velocity, but the distribution of the liquid film thickness on circumferential position almost constant in the region of 300mm down stream from carburetor. 3) The mean liquid film thickness is 0.04 - 0.18mm in case of methanol in the region of air velocity Va = 12m/s - 55m/s and decreases with decreasing the throttle valve angle.

  • PDF

지지막을 이용하는 액막 추출기 내에서 아연 이온의 이동 (Transport of Zinc Ion in a Contained Liquid Membrane Permeator with Two Micro-Porous Films)

  • 주창식;이석희;이민규;홍성수;하홍두;정석기
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.159-164
    • /
    • 2000
  • For the purpose of development of a liquid membrane permeator which separates metal ions from aqueous solutions continuously and effectively, a continuous membrane permeator with the membrane solution trapped between extraction and stripping phases by two micro-porous hydrophilic films was manufactured. Experimental researches on the separation of zinc ion from aqueous solutions were performed in the liquid membrane permeator with 30 vol % D2EHPA solution in kerosine as liquid membrane. As results, the liquid membrane permeator separates zinc ion from aqueous solutions continuously and effectively in the wide range of operating conditions. A simple mass transfer rate model using equilibrium constant of the extraction reaction for the system used were proposed, and the model was compared with experimental results of separation of zinc ion in the permeator. And the effects of operating factors, such as space time, pH of extraction solution, extraction temperature, on the separation rate of zinc ion in the permeator were experimentally examined.

  • PDF