• Title/Summary/Keyword: Constant level

Search Result 1,799, Processing Time 0.027 seconds

Constant-level luffing and time optimal control of a JIB crane (JIB크레인의 Constant-level luffing과 시간최적제어)

  • 최경배;홍금식;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1788-1791
    • /
    • 1997
  • In this paper constant-level luffing and time optimal control of a JIB crane is investigated. The crane is assumed to have only the derricking motion. the analysis of plance kinematics provides the relationship between the boom angle and the main hosit motor angle for constant-level luffing. The dynamic equations for the crane are very nonlimear, and therefore they are linearized for the application of the linear control theory. The time optimal control in the perspective of no-sway at the end of boom stroke is investigated.

  • PDF

Three level constant stress accelerated life tests for Weibull distribution

  • Moon, Gyoung Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.1
    • /
    • pp.281-288
    • /
    • 2015
  • In this paper, the maximum likelihood estimators and confidence intervals for parameters of Weibull distribution are derived under three level constant stress accelerated life tests and the assumption that a log quadratic relationship exits between stress and the scale parameter ${\theta}$. The compound linear plan proposed by Kim (2006) is used to allocate the test units at each stress level, which performed nearly as good as the optimum quadratic plan and had the advantage of simplicity. Some simulation studies are given.

A New Approach to an Inventory with Constant Demand

  • Lee, Eui-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1345-1352
    • /
    • 2008
  • An inventory with constant demand is studied. We adopt a renewal argument to obtain the transient and stationary distribution of the level of the inventory. We show that the stationary distribution can be also derived by making use of either the level crossing technique or the renewal reward theorem. After assigning several managing costs to the inventory, we calculate the long-run average cost per unit time. A numerical example is illustrated to show how we optimize the inventory.

  • PDF

Logic gate implementation of constant amplitude coded CS/CDMA transmitter (정포락선 부호화된 CS-CDMA 송신기의 논리 게이트를 이용한 구현)

  • 김성필;류형직;김명진;오종갑
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.281-284
    • /
    • 2003
  • Multi-code CDMA is an appropriate scheme for transmitting high rate data. However, dynamic range of the signal is large, and power amplifier with good linearity is required. Code select CDMA (CS/CDMA) is a variation of multi-code CDMA scheme that ensures constant amplitude transmission. In CS/CDMA input data selects multiple orthogonal codes, and sum of these selected codes are MPSK modulated to convert multi-level symbol into different carrier phases. CS/CDMA system employs level clipping to limit the number of levels at the output symbol to avoid hish density of signal constellation. In our previous work we showed that by encoding input data of CS/CDMA amplitude of the output symbol can be made constant. With this coding scheme, level clipping is not necessary and the output signal can be BPSK modulated for transmission. In this paper we show that the constant amplitude coded(CA-) CS/CDMA transmitter can be implemented using only logic gates, and the hardware complexity is very low. In the proposed transmitter architecture there is no apparent redundant encoder block which plays a major role in the constant amplitude coded CS/CDMA.

  • PDF

Constant Current & Constant Voltage Battery Charger Using Buck Converter (벅 컨버터를 이용한 정전류 정전압 배터리 충전기)

  • Awasthi, Prakash;Kang, Seong-Gu;Kim, Jeong-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.399-400
    • /
    • 2012
  • The proposed battery charger presented in this paper is suitable for Lead-Acid Battery and the dc/dc buck converter topology is applied as a charger circuit. The technique adopted in this charger is constant current & constant voltage dual mode, which is decided by the value of voltage of proposed battery. Automatic mode change function is detected by the percentage value of level of battery charging. CC Mode (Constant Current Mode) is operated when charging level is below 80% of the total charging of Battery voltage and above 80% of battery voltage charging, CV Mode (Constant Voltage Mode) is automatically operated. As the charging level exceeds 120%, it automatically terminates charging. The feedback signal to the PWM generator for charging the battery is controlled by using the current and voltage measurement circuits simultaneously. This technique will degrade the damage of proposed type of battery and improve the power efficiency of charger. Finally, a prototype charger circuit designed for a 12-V 7-Ah lead acid battery is constructed and tested to confirm the theoretical predictions. Satisfactory performance is obtained from simulation and the experimental results.

  • PDF

A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes (항공관제용 정전류조정(CCR) 인버터 시스템의 개발)

  • Shon, Jin-Geun;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Relation between sound pressure level and auditory distance perception in anechoic room (무향실에 있어서의 음압레벨과 거리정위와의 관계)

  • Kim, Hae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.6
    • /
    • pp.1201-1206
    • /
    • 2009
  • According to a lot of investigations, distance perception is influenced by many important cues such as sound pressure level, reflections from the room surface, binaural difference (ITD and ILD), a kind of sound source, and head related transfer functions (HRTF). Two psychoacoustical experiments on auditory distance perception were conducted to examine the effectiveness of the sound pressure level loudness as one of the physical cues in the auditory distance perception under a constant loudspeaker's output level and a constant sound level at the subject's position in the absence of reflections in an anechoic room. Our experimental results showed that the perceived distance of sound image is closer than actual sound source distance with the constant loudspeaker's output level and the constant sound level. Futhermore, the perceived distance of a sound image with constant sound level increased when the actual distance increases up to approximately 2 m while the perceived distance saturated when the sound source distance exceed 2 m. On the other hand, when the condition of loudspeaker's output level was kept constantly, the perceived distance of sound image increased up to around 3m, longer than the conditions of constant sound level at the subject's position. We found that the change in the loudness as a function of distance plays an important role in the auditory distance perception in the absence of reflections..

Effect of the Measuring Method of Reverberation Time Using Impulse Response Method on the Normalized Impact Sound Pressure Level (임펄스응답적분법을 이용한 잔향시간의 측정방법이 규준화 바닥충격음레벨에 미치는 영향)

  • Lee, J.W.;Kwon, Y.P.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.34-39
    • /
    • 2006
  • For the evaluation of the normalized impact sound pressure level, the reverberation time of the receiving room should be measured. This paper deals with the effect of the time constant of FFT analyzer and the measuring points on reverberation time. It is found that the time constant should be in the range between 10 ms and 35 ms. While the effect of measuring points on the reverberation time is significant when the bandwidth is narrow it is negligible in the evaluation of the normalized impact sound pressure level.

An Order Level Inventory Model for Deteriorating Items with Power Pattern Demand

  • Hwang, Hark;Ree, Paek
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.5 no.1
    • /
    • pp.53-59
    • /
    • 1980
  • An order level inventory model is developed for deteriorating items. The demand during prescribed scheduling period is constant and deterministic in which the demand follows power pattern. Deterioration is assumed to be a constant fraction of the on hand inventory. The expression for the optimal order level is developed and an example is given to illustrate the model.

  • PDF