• Title/Summary/Keyword: Constant frequency

Search Result 2,454, Processing Time 0.036 seconds

Constant Frequency Adjustable Power Active Voltage Clamped Soft Switching High Frequency Inverter using The 4th-Generation Trench-Gate IGBTs

  • Miyauchi T.;Hirota I.;Omori H.;Terai H.;Abdullah Al Mamun;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.236-241
    • /
    • 2001
  • This paper presents a novel prototype of active voltage-clamping capacitor-assisted edge resonant soft switching PWM inverter operating at a constant frequency variable power (VPCF) regulation scheme, which is suitable for consumer high-power induction-heating cooking appliances. New generation IGBT with a trench gate is particularly improved in order to reduce conduction loss due to its lowered saturation voltage characteristics. The soft switching load resonant and quasi-resonant inverter designed distinctively using the latest IGBTs is evaluated from an experimental point of view.

  • PDF

Common Mode Voltage Cancellation in a Buck-Type Active Front-End Rectifier Topology

  • Aziz, Mohd Junaidi Abdul;Klumpner, Christian;Clare, Jon
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.276-284
    • /
    • 2012
  • AC/AC power conversion is widely used to feed AC loads with a variable voltage and/or a variable frequency from a constant voltage constant frequency power grid or to connect critical loads to an unreliable power supply while delivering a very balanced and accurate sinusoidal voltage system of constant amplitude and frequency. The load specifications will clearly impose the requirements for the inverter stage of the power converter, while wider ranges of choices are available for the rectifier. This paper investigates the utilization of a buck-type current source rectifier as the active front-end stage of an AC/AC converter for applications that require an adjustable DC-link voltage as well as elimination of the low-frequency common mode voltage. The proposed solution is to utilize a combination of two or more zero current vectors in the Space Vector Modulation (SVM) technique for Current Sources Rectifiers (CSR).

Hydraulic Constant Frequency Generation System Driven by Main Engine for Small Fishing Boat - Hydraulic Pump Control Type - (소형 어선용 주기구동 유압식 고주파수 발전장치에 관한 연구 ( 1 ) - 유압펌프 제어방식 -)

  • Lee, Il-Yeong;Park, Sang-Gil;Jeong, Yong-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.30-35
    • /
    • 1988
  • An electrical power generation system driven by main engine shaft, briefly SG system for middle or small size fishing boat is studied experimently. In the SG system, power transmission is performed by a variable displacement hydraulic pump driven by the main engine and a constant displacement hydraulic motor. It was verified that the SG system enabled the generation of electrical power with constant frequency regardless main engine speed. In the SG system, setting reference frequency, sensing generator output frequency and setting controller parameters are performed by performed by programming in a microcomputer, so a countermeasure for physical situations of control object is very easy. Futhermore, the SG system has following features; low initial installation cost, wide freedom of installation in engine room, advantage of application in existing ships, especially fishing boat with hydraulic fishing equipments.

  • PDF

A Modeling and Analysis of Electric Railway System Using Constant Power Model (정전력모델을 이용한 전기철도 시스템의 회로 모델링 및 해석기법)

  • 홍재승;김주락;오광해;창상훈;김정훈
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.116-122
    • /
    • 2000
  • This paper presents a simulation method with constant power model for the train load. In power system simulation loads could be modeled as a constant power, constant current, constant Impedance or a function of voltage and frequency. At this time, however, representing a train load as the function is difficult because of the lack of data. Therefore as a first step, simulation method with a constant power model fer a train is studied, and the test result is compared with the simulation result using the constant Impedance model.

  • PDF

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

Attempt Frequency of Magnetization in Synthetic Antiferromagnet (인위적 반강자성체에서 자화의 시도주파수)

  • Sur, Hong-Ju;Lee, Kyung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.1
    • /
    • pp.1-4
    • /
    • 2009
  • Solving the stochastic Landau-Lifshitz-Gilbert equation numerically, we investigate the attempt frequency of magnetization in synthetic antiferromagnet (SyAF). The attempt frequency is estimated while varying the uniaxial anisotropy constant, the energy barrier and the geometry of a magnetic layer. It is found that the attempt frequency is decreased for the same magnetic volume by increasing the asymmetry of the geometry in the high damping region. Also, even for a constant height of energy barrier, the attempt frequency can vary dramatically with uniaxial anisotropy constant.

A Dielectric Constant Measurement Method of Unprepared Samples (비가공 물질의 유전 상수 측정 방법)

  • Lee, Won-Hui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.896-900
    • /
    • 2008
  • A measurement method of the dielectric constant of materials whose standard sample is not prepared easily is proposed. The unprepared sample of the material is placed in a cavity, and the resonant frequency is measured. A commercial software simulates the same sample and the cavity leading to find the correct dielectric constant. The measured samples include a ceramic, a forced glass, and a powdered enamel. The measured dielectric constant of a ceramic, a forced glass, and a powdered enamel are 11-j0.0033(${\epsilon}_{\gamma}=11,\;tan{\delta}=0.0003$), 4.15-j0.053(${\epsilon}_{\gamma}=4.15,\;tan{\delta}=0.0128$), and 3.9-j0.042(${\epsilon}_{\gamma}=3.9,\;tan{\delta}=0.0108$) respectively.

A study on the slip frequency control of linear induction motor for magnetic levitation transit (자기 부상 열차용 리니어모터의 슬립 주파수 제어에 관한 연구)

  • Im, Dal-Ho;Kim, Gyu-Tak;Kim, Young-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.135-138
    • /
    • 1991
  • In this study, a variety of characteristics is considered when LIM for transit is driven with acceleration and deceleration. From the characteristics of constant voltage, with V/f ratio fixed, slip frequency is derived. With slip frequency of 12[Hz] and objective velocity of 40[km/h], the robust control characteristics which are generated constant thrust and normal force, except for open-loop control interval, are obtained.

  • PDF

Resinant DC-DC Converter with Constant Switching frequency (스위칭 주파수가 일정한 공진형 DC-DC코버어터)

  • 이윤종;김희준;안태영;박효식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.3
    • /
    • pp.266-274
    • /
    • 1991
  • This paper proposed the resonant DC-DC converter with constant switching frequency. Its output is controlled by the auxiliary switch which is attached in conventional MRC circuits. The average output voltage is equal to the average voltage of the auxiliary switch. If the on time of the auxiliary switch is short, output voltage is decreased. Because of using the multi resonant method, the power loss from the parasitic elements can be decreased. Experimental performance of DF ZVS Forward MRC topology with switching frequency of 1MHz is presented.

Slip Frequency Andative Tunning for the Compensation of Rotor Resistance Variation of Induction Motor (유도전동기의 회전자저항 변동 보상을 위한 슬립주파수의 적응 조정)

  • 이일형;이윤종
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.42-48
    • /
    • 1994
  • A rotor flux error-based approach for correcting the rotor time constant estimation used in the slip frequency calculator of indirect field oriented controller is presented in this paper. The controller was derived from the d-q induction machine model. Slip frequency gain is dependent on the machine parameter errors. And parameter errors result in rotor flux error. Thus, estimated rotor flux is compared to commanded rotor flux. The error between them is used for the estimation of rotor time constant. Simulation results which demonstrate the performance of this approach are presented.

  • PDF