• Title/Summary/Keyword: Constant Temperature

Search Result 5,132, Processing Time 0.038 seconds

Measuring Convective Heat Transfer Coefficients of Nanofluids over a Circular Fine Wire Maintaining a Constant Temperature (등온으로 유지되는 가는 열선주위를 흐르는 나노유체의 대류열전달계수 측정실험)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • This paper describes a measuring apparatus that can be used to appraise the effectiveness of nanofluids as new heat-transfer-enhancing fluids. A couple of apparatuses using fine hot wires as sensors have been proposed for this purpose; however, they have a technical weakness related to the uncertain working conditions of the sensor. The present method uses the convective heat transfer coefficient from a hot wire as an indication of the heat transfer effectiveness of the nanofluid, where the temperature of the wire remains constant during the experiment. The operating principle and experimental procedure are explained in detail, and the validity of the system is tested with pure base fluids. The effects of particle concentration, velocity, and temperature on the heat transfer coefficients of the nanofluids are discussed comprehensively using the experimental data for graphite nanolubrication oil.

Bond behavior between circular steel tube and high-strength concrete after elevated temperatures

  • Ji, Zhou;Zongping, Chen;Maogen, Ban;Yunsheng, Pang
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.575-590
    • /
    • 2022
  • In this paper, bond-slip behavior of high strength concrete filled circular steel tube (HSCFCST) after elevated temperatures treatment was studied. 17 specimens were designed for push-out test. The influence was discussed as following parameters: (a) concrete strength, (b) constant temperature, and (c) bond length. The results showed that (1) after elevated temperatures treatment, the bond strength of the HSCFCST specimens increased first and then decreased with temperature rising; (2) the bond strength increased with the increase of concrete strength at room temperature, while the influence subsided after elevated temperatures treatment; (3) the strain of the circular steel tube was distributed exponentially along its length, the stress changed from exponential distribution to uniform distribution with the increase of load; (4) the bond damage process was postponed with the increase of constant temperature; and (5) the energy consumption capacity of the bonding interface increased with the rise of concrete strength and constant temperature. Moreover, computational formulas of ultimate and residual bond strength were obtained by regression, and the bond-slip constitutive models of HSCFCSTs after elevated temperatures was established.

Optimum Design of Multi-Stacking Current Lead Using HTS Tapes (고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계)

  • 설승윤;김민수;나필선
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF

Optimal Design of Multi-Step Current Leads Using HTS Tapes (고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계)

  • 김민수;나필선;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF

A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself (정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구)

  • Park, Jong-Il;Chun, Kwang-Min;Hahn, Jae-Won;Park, Chul-Woong
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF

Theoretical Calculation of Parabolic Rate Constant for High-Temperature Oxidation of Metals (금속의 고온 산화동안 포물선 속도상수의 이론적 계산)

  • Kim, Insoo;Cho, Weol Dong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.282-285
    • /
    • 2001
  • Based on the mass balance of anion and cation fluxes, the parabolic rate constant ($K_p$) of oxide grown during the high-temperature oxidation of metal is theoretically calculated. It is assumed that the diffusion of oxygen anion and metal cation through oxide scale obeys the Fick's 1st law, the growth of oxide is controlled by the diffusion of ions, electrical potential gradient as driving force for diffusion of ions is ignored, and oxidation occurs within an existing oxide layer. Then, the parabolic rate constant can be expressed by $K_p=[2{\rho}_{MmOn}{M^2}_{MmOn}(mD_oC_o{^e}+nD_MC_M{^e})/nm]$.

  • PDF

A new low dielectric constant barium titanate - poly (methyl methacrylate) nanocomposite films

  • Upadhyay, Ravindra H.;Deshmukh, Rajendra R.
    • Advances in materials Research
    • /
    • v.2 no.2
    • /
    • pp.99-109
    • /
    • 2013
  • In the present investigation, nanocomposite films with poly(methyl methacrylate) (PMMA) as a polymer matrix and barium titanate as a filler were prepared by solution casting method. Barium titanate nano particles were prepared using Ti(IV) triethanolaminato isopropoxide and hydrated barium hydroxide as precursors and tetra methyl ammonium hydroxide (TMAH) as a base. The nanocomposite films were characterized using XRD, FTIR, SEM and dielectric spectroscopy techniques. Dielectric measurements were performed in the frequency range 100 Hz-10 MHz. Dielectric constant of nanocomposites were found to depend on the frequency, the temperature and the filler fraction. Dissipation factors were also influenced by the frequency and the temperature but not much influenced by the filler fractions. The 10 wt% of BT-PMMA nanocomposite had the lowest dielectric constant of 3.58 and dielectric loss tangent of 0.024 at 1MHz and $25^{\circ}C$. The dielectric mixing model of Modified Lichtenecker showed the close fit to the experimental data.

Dielectric Properties of Strontium-substituted Lead Magnesium Tungstate up to Microwave Frequencies

  • Kim, J.H.;Choo, W.K.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.394-398
    • /
    • 1998
  • $Pb_{1-x}Sr_x(Mg-{1}2}W_{1}2})O_3$$ ceramics for application in the microwave frequency range were investigated by dielectric constant and X-ray diffraction measurements. The dielectric constant curves showed two concentration dependent characteristics in the $$Pb(Mg-{1}2}W_{1}2})O_3$-rich$ region. As the Sr constant further increases to x=0.3 the dielectric curve levels off. In the concentration range between x=0.4 and x=1 in which dielectric constant dependence on temperature is negligible, it decreases and Qf value increases in the microwave frequency with increasing Sr. The temperature coefficient (${\tau}_{\varepsilon} $) of the dielectric constant changes from the negative to positive value between x=0.9 and x=1. The dielectric constant, Qf and $\tau\varepsilon$ are correlated with tolerance factor(t). From the X-ray diffraction results for $0.1{\le}x{\le}1$ the cell parameter is found to decrease as x increases and B-site ordering is observed in all the composition ranges.

  • PDF

Effect of the Stagnation Temperature on the Normal Shock Wave

  • Zebbiche, Toufik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.10 no.1
    • /
    • pp.1-14
    • /
    • 2009
  • When the stagnation temperature increases, the specific heat does not remain constant and start to vary with this temperature. The gas is perfect, it's state equation remains always valid, except, it was called by gas calorically imperfect or gas at high temperatures. The purpose of this work is to develop a mathematical model for a normal shock wave normal at high temperature when the stagnation temperature is taken into account, less than the dissociation of the molecules as a generalisation model of perfect for constant heat specific. A study on the error given by the perfect gas model compared to our model is presented in order to find a limit of application of the perfect gas model. The application is for air.

Calibration Equation for VTA Including the Effect of Ambient Temperature Drift (온도변화를 고려한 가변온도형 열선유속계의 교정식)

  • Lee, Shin-Pyo;Kauh, S.-Ken
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.99-104
    • /
    • 2000
  • Calibration equation for Variable Temperature Anemometer(VTA) has been tested for measured velocity-output data and the calibration process has been compared with that of Constant Temperature Anemometer(CTA). VTA has greater sensitivity than that of any other conventional anemometers, but to be more popular technique in flow field measurement, simple, accurate and well established calibration process should be suggested. To meet this purpose, similar calibration method used for CTA has been adopted for VTA and finally calibration equation for VTA including the effect of temperature drift has been proposed.

  • PDF