• Title/Summary/Keyword: Constant Current Circuit

Search Result 343, Processing Time 0.025 seconds

Design and Analysis of 20 W Class LED Converter Considering Its Control Method (제어 방식에 따른 20 W급 LED Converter 설계 및 분석)

  • Jeong, Young-Gi;Kim, Sung-Hyun;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.

Pyro Squib Circuit Design with Stable Constant Current Driving Method (안정적인 정전류 구동 방식의 파이로 스퀴브 회로 설계)

  • Soh, KyoungJae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.545-551
    • /
    • 2022
  • We proposed a design method for constant current pyro squib circuit. The current method using N MOSFET for the stability problem has a weakness of the current change, requiring a new design. This paper identified the problem with conventional squib circuit where the current is reduced by 25 % when maximum resistance is 3 ohms. Thus, we proposed a stable constant current driving circuit using P MOSFET and PNP BJT. We confirmed stable constant circuit operation through simulations and measurements of the proposed circuit design where the current did not change until the resistance reached 3 ohms.

A Study on the Mathematical Modeling and Constant Current Adaptive Controller Design for Power LEDs (파워 LED의 수학적 모델링 및 정전류 적응 제어기 설계에 관한 연구)

  • Kim, Eung-Seok;Kim, Young-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.8-13
    • /
    • 2011
  • In this paper, a mathematical model of the power LED system including the drive circuit will be presented to control the power LEDs current. Using this mathematical model, the constant current adaptive controller will be designed. A constant current drive circuit for power LEDs will be configured using Buck-type converter. Precise constant current controller design is enabled by presenting the mathematical model of power LEDs including the current driving circuits. Using the mathematical model of power LEDs and its drive circuits, the constant current adaptive controller will be designed to obtain the robustness for the parameter uncertainties. In order to verify the validity of the proposed controller, computer simulations are performed.

Simple analysis on induction motor dynamic performances by time constant parameter (유도전동기의 동특성해석에 있어서의 Time constant parameter에 의한 간이해석법)

  • 황영문
    • 전기의세계
    • /
    • v.31 no.2
    • /
    • pp.126-131
    • /
    • 1982
  • Induction motors are known to cause voltage dip, oscillating torque and inrush current on the dynamic period. To compensate for these undesirable effects, the prediction of dynamic performances is required. The dynamic performances are determinated by circuit time constants. From this point of view, in this paper, the dynamic equivalent circuit included only three time-constant parameters are presented. To predict more simply dynamic performances, the new characteristics time constant parameters are analyzed, and now these parameters are described as the function of circuit time constants. This paper reviews and analyzes the use of series capacitance compensations, and the use of this analysis can make simply a prediction about oscillating conditions.

  • PDF

Probeless Estimation of Electroluminescence Intensities Based on Photoluminescence Measurements of GaN-Based Light-Emitting Diodes

  • Kim, Jongseok;Jeong, Hoon;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • The electroluminescence (EL) intensities of GaN-based light-emitting diodes (LEDs) are estimated based on their photoluminescence (PL) properties. The PL intensity obtained under open-circuit conditions is divided into two parts: the PL intensity under a forward bias lower than the optical turn-on voltage, and the difference between the PL intensities under open-circuit conditions and under forward bias. The luminescence induced by photoexcitation under a constant forward bias lower than the optical turn-on voltage is primarily the PL from the excited area of the LED. In contrast the intensity difference, obtained by subtracting the PL intensity under the forward bias from that under open-circuit conditions, contains the EL induced by the photocarriers generated during photoexcitation. In addition, a reverse photocurrent is generated during photoexcitation under constant forward bias across the LED, and can be correlated with the PL-intensity difference. The relationship between the photocurrent and PL-intensity difference matches well the relationship between the injection current and EL intensity of LEDs. The ratio between the photocurrent generated under a bias and the short-circuit current is related to the ratio between the PL-intensity difference and the PL intensity under open-circuit conditions. A relational expression consisting of the ratios, short-circuit current, and PL under open-circuit conditions is proposed to estimate the EL intensity.

A Study on Applications and Design of Driving Controller Circuit in hybrid Stepping Motor (Hybrid Stepping Motor의 Driving Controller 설계와 응용에 관한 연구)

  • 최도순
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.6 no.2
    • /
    • pp.74-79
    • /
    • 2001
  • The Stewing Motor has applied for engineering technology and that special used to auto mobile technology, robot technology and still more automatic machinery. If it make used to the motor for automatic machinery. That have high precision step of motor and high efficiency. n order to operation in this paper, the static position of motor to have analyzing, comparison of constant voltage control methode and constant current methode. And designed to a controller circuit of 4 phase unipolar driving and 2 phase bipolar driving of stepping motor.

  • PDF

Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters (단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석)

  • 강규홍;홍정표
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

A Newly Proposed Bias Stability Circuit for MMIC율s Yield Improvement (초고주파 집적회로의 수율향상을 위한 새로운 바이어스 안정화 회로)

  • 권태운;신상문;최재하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.882-888
    • /
    • 2002
  • This paper proposed a bias stability circuit that compensates the degradation of MMIC's performance for the variation of the process and temperature. The proposed bias circuit proved the superior effect compared with the conventional bias circuit using the constant current source. It designed and fabricated simultaneously two amplifier on one layout for comparison in same conditions. One is amplifier with conventional bias circuit using constant current source and the other is amplifier with proposed bias stability circuit. The chip was measured the microwave performances under process variation that classed the level NOM, MIN and MAX. The amplifier with a conventional bias circuit using constant current source has 6.4 dB gain variation and 7 mA Ids variation at 1.8 GHz, but the amplifier with the proposed bias circuit has the 2.1 dB gain variation and 3 mA Ids variation. As the result, MMIC having the proposed bias circuit shows the superior compensation of the quiescent point than the MMIC having the conventional bias circuit under the variations of the process and temperature and can improve the yield of the MMIC. The fabricated chip size is 1.2 mm $\times$ 1.4 mm.

Design of the 140W level-small sized LED Power Control Circuit (140W 급-저면적 LED 전원 제어 회로 설계)

  • An, Ho-Myoung;Lee, Juseong;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.586-592
    • /
    • 2018
  • In this paper, HIC with various functions is proposed for the design 140W LED power control circuit. The proposed HIC integrates constant voltage/constant current circuit, short circuit protection circuit, internal constant voltage circuit, and dimmer circuit, thereby reducing the horizontal length of the PCB by 16% comparing with the conventional system. Through various experiments, we verified the performance of each block implemented inside of HIC with numerical results. (Constant voltage variation ratio: 2.9%, dimmer circuit duty variation within 5%, stable short protection at 720 mA) Since the PCB area can be significantly reduced by applying the proposed HIC. It is possible to reduce the PCB manufacturing time which takes up most of the manufacturing time, however, It is expected that the faulted power module can be replaced without replacing the whole PCB, so that maintenance / repair can be made easier.

Soft-Start Open Circuit Voltage and Constant Current Sequence Control of 2.5[kW] HID Search Lamp for Ship (선박용 2.5[kW] HID 탐사등의 Soft-Start 방식에 의한 개방회로 전압과 점등전류 순차 제어)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.45-51
    • /
    • 2008
  • HID(High Intensity Discharge) search lamp for shipment requires a high open circuit and output current compare than vehicle. This paper presents a soft-start open circuit voltage and constant current sequence control method for 2.5[kW] HID search lamp. The proposed method controls the opal circuit voltage and discharge current of HID lamp according to ignition signal with a simple 8-bit micro-processor and PWM device. For the stable control of lamp, micro-processor checks the output voltage and current. And the checked signals are compared with ignition signal and changes the control mode for stable operation. An ignition signal and micro-processor change the control mode from open circuit voltage contort to constant current control. The proposed control scheme is verified from experimental tests of 2.5[kW] HID search lamp for shipment.