• Title/Summary/Keyword: Conservative Wave

Search Result 116, Processing Time 0.022 seconds

DEVELOPMENT OF NEW FREQUENCY-DEPENDENT TYPE APEX LOCTOR ; VOLTAGE DIFFERENCE COMPENSATING TYPE (주파수의존형 전자근관장측정기의 개발과 정확도에 관한 연구 ; 전압차 자동보정형)

  • Lee, Seung-Jong;Kim, Deok-Won;Nam, Ki-Chang
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.809-819
    • /
    • 1997
  • The purpose of this study was to develop an accurate frequency-dependent type apex locator. To compensate the impedence differences of different canal contents, voltage differences were pre-measured and stored for saline, HOsb1/$2O_2$ and NaOCl. The circuit was adjusted to recognize the different voltages of each solution, thereby the machine could automatically compensate the voltage differences. In the process of this study, the following informations were observed. 1. Most stable apical reading was obtained at 500Hz and 10kHz. 2. There were no differences in accuracy among three different frequency types, sign wave, triangular wave and rectangular wave(p>0.05). 3. Before the compensation of voltage differences, saline, H2O2 and NaOCl showed different readings at the apex even with the frequency-type (p<0.05). 4. After compensating the voltage difference, the accuracy was enhanced from + 0.42 to +0.32 in H2O2(p<0.05), from -0.34 to -0.12 in NaOCl(p<0.05).

  • PDF

COLLOCATION METHOD USING QUARTIC B-SPLINE FOR NUMERICAL SOLUTION OF THE MODIFIED EQUAL WIDTH WAVE EQUATION

  • Islam, Siraj-Ul;Haq, Fazal-I;Tirmizi, Ikram A.
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.3_4
    • /
    • pp.611-624
    • /
    • 2010
  • A Numerical scheme based on collocation method using quartic B-spline functions is designed for the numerical solution of one-dimensional modified equal width wave (MEW) wave equation. Using Von-Neumann approach the scheme is shown to be unconditionally stable. Performance of the method is validated through test problems including single wave, interaction of two waves and use of Maxwellian initial condition. Using error norms $L_2$ and $L_{\infty}$ and conservative properties of mass, momentum and energy, accuracy and efficiency of the suggested method is established through comparison with the existing numerical techniques.

THE SEALING ABILITY OF OBTURATION TECHNIQUES IN OPEN APEX (개방 근첨 치아의 근관 충전방법에 따른 치근단 폐쇄효과에 관한 연구)

  • So, Hyun;Choi, Ho-Young;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.435-445
    • /
    • 2000
  • The purpose of this study was to compare the leakage of four different obturation techniques in conjunction with immediate apical barrier of ${\beta}$-tricalcium phosphate(TCP) in teeth with open apex. Eighty single-rooted human premolar teeth were prepared and sectioned horizontally, so maximum diameter in apex was 4mm. Apical defects that were similar to open apex, were created with #1/2 round bur and SF104R bur. The apical foramen were opened to a size 80 file extended 3mm beyond the apex. The teeth were placed into the oasis block soaked saline to simulate periapical tissue often associated with pulpless teeth and received apical barriers consisting of TCP followed by obturation using lateral condensation technique, vertical condensation technique, continuous wave technique and thermoplasticized gutta-percha injection technique. Two unobturated teeth served as positive and negative controls. Teeth were immersed in resorcinol-formaldehyde resin for S days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then sectioned horizontally at 1.5mm(level 1), 2.5mm(level 2) and 3.5mm(level 3) from the apex, and examined under a stereomicroscope at ${\times}40$ magnification. The photographs were taken at ${\times}40$ magnification of the filling in each level and scanned. The leakage length in tooth/resin interface was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the leakage length of canal wall infiltrated with resin to the total length of the canal and was analyzed statistically(One-way ANOVA and Scheffe test). The result were as follows : 1. At the level 1, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), and the most leakage in the continuous wave technique group(group 3). There was statistically significant difference between the thermoplasticized gutta-percha injection technique group and the continuous wave technique group(p<0.05). 3. At the level 3, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there were no statistically significant differences between other groups(p>0.05). These results suggest that thermoplasticized gutta-percha injection technique which had 1mm apical gutta-percha matrix after the formation of TCP apical barrier, can demonstrate favorable apical sealing.

  • PDF

COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM (측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교)

  • Lim, Dong-Yeul;Lee, Hee-Joo;Hur, Buck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL (제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과)

  • Choi, Hee-Won;Kim, Soo-Mee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal. 50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block. The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip. All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (${\times}2.3$). The results are as follows : 1. In control group, there was no gutta-percha and sealer in lingual canal. 2. 3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05). 3. 7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05) In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.

Wave passage effect of seismic ground motions on the response of multiply supported structures

  • Zhang, Y.H.;Lin, J.H.;Williams, F.W.;Li, Q.S.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.6
    • /
    • pp.655-672
    • /
    • 2005
  • Seismic random responses due to the wave passage effect are extensively investigated by using the pseudo excitation method (PEM). Two examples are used. The first is very simple but also very informative, while the second is a realistic suspension bridge. Numerical results show that the seismic responses vary significantly with wave speed, especially for low velocity or large span. Such variations are not monotonic, especially for flexible structures. The contributions of the dynamic and quasi-static components depend heavily on the seismic wave velocity and the natural frequencies of structures. For the lower natural frequency cases, the dynamic component has significant effects on the dynamic responses of the structure, whereas the quasi-static component dominates for higher natural frequencies unless the wave speed is also high. It is concluded that if insufficient data on local seismic wave velocity is available, it is advisable to select several possible velocity values in the seismic analysis and to choose the most conservative of the results thus obtained as the basis for design.

Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments

  • Yilmaz, Koray;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.134-139
    • /
    • 2017
  • Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files

  • Uslu, Gulsah;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.22.1-22.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

EFFECTIVENESS OF CUSTOMIZED MASTER CONE ON APICAL SEALING IN VARIOUS APICAL SIZE OF PREPARED ROOT CANALS (근단부 크기에 따른 customized master cone의 치근단 밀폐효과에 관한 연구)

  • Hong, Hye-Young;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.66-76
    • /
    • 2002
  • The purpose of this study is to evaluate the effectiveness of customized master cone on apical sealing in various apical size of prepared root canals, that is MAF(Master Apical File) and to know at which apical size the apical leakage is to be significantly reduced using customized master cone. 120 extracted single rooted premolars were divided into four groups according to their apical size(MAF), #30, 40, 50 and 60. And then, each group was subdivided into three in accordance with three obturation methods, lateral condensation with standardized master cone, lateral condensation with chloroform-dipped customized master cone, and continuous wave of obturation technique. Resorcinol-formaldehyde resin was used for the microleakage test of this study. Teeth were sectioned horizontally at 1.5mm(Level 1), 2.5mm(Level 2), and 3.5mm(Level 3) from the anatomical root apex using low speed microtome. All sections were examined under $\times$40 magnification with a stereomicroscope, photographed, and then scanned. With the scanned images, resin-infiltrated area presenting the microleakage was calculated using SigmaScan/Image, and the ratio of leakage to the total root canal area of each group was analyzed statistically(one way ANOVA). The results were as follows ; 1. In groups of MAF #30, there was no significant difference of mean leakage ratio among three obturation methods at all three levels. 2. In groups of MAF #40, the group using lateral condensation with customized master cone had the low-est mean leakage ratio at all three levels, but there was no significant difference among three obturation techniques. 3. In groups of MAF #50, the mean leakage ratio of the group using lateral condensation with standard master cone was the highest among those of three obturation techniques at level 1, and this difference was statistically significant(p<0.05). 4 In groups of MAF #60, the groups using lateral condensation with standard master cone had also the highest mean leakage ratio at all levels, but there was no significant difference at level 1 and 2. At level 3, the leakage of the group using lateral condensation with standard master cone was significantly higher than that of the group using continuous wave of obturation(p<0.05). The results of this study suggested that the obturation method using customized master cone or the continuous wave of obturation is more effective for apical sealing than that using standardized master cone when MAF is larger than #50.

Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals

  • Kirici, Damla;Kustarci, Alper
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.36.1-36.6
    • /
    • 2019
  • Objectives: The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial doublecurvature canals. Materials and Methods: This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results: The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions: In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.